AXL F BK PN 2701815 PHOENIX CONTACT Axioline F bus coupler for PROFINET (including bus base module and conne.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

AXL F BK PN 2701815 PHOENIX CONTACT Axioline F bus coupler for PROFINET (including bus base module and conne..

AXL F BK PN

2701815

PHOENIX_CONTACT

Available

Ship on today

Axioline F bus coupler for PROFINET (including bus base module and connector)

More details


AUTOMATION Industrial Automation - PHOENIX CONTACT

Ethernet networks. Switches, routers, and antennas - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article is obsolete. Please ask us for a quotation and we will check if there are units available or we will offer you an alternative product.

Related products

More info



Product description

The bus coupler is the link between a PROFINET network and the Axioline F system.

Up to 63 Axioline F devices can be connected to an existing Ethernet system using the bus coupler.

Dimensions

Width45 mm
Height125.9 mm
Depth74 mm
Note on dimensionsThe depth is valid when a TH 35-7.5 DIN rail is used (according to EN 60715).

Ambient conditions

Ambient temperature (operation)-25 °C ... 60 °C (Mounting position: wall mounting on horizontal DIN rail)
-25 °C ... 55 °C (Mounting position: any)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP20

Connection data

DesignationAxioline F connector
Connection methodPush-in connection
Note on connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Stripping length8 mm

General

Net weight222 g
Note on weight specificationswith connector and bus base module
Mounting typeDIN rail mounting

Interfaces

Fieldbus systemPROFINET
DesignationPROFINET
Connection methodRJ45 socket, auto negotiation and auto crossing
Transmission speed100 MBit/s (Full duplex)
Transmission physicsEthernet in RJ45 twisted pair
Fieldbus systemLokalbus
DesignationAxioline F local bus
Connection methodBus base module
Transmission speed100 MBit/s
DesignationService
Connection methodMicro USB type B

System limits of the bus coupler

Number of supported devicesmax. 63 (per station)
Number of local bus devices that can be connectedmax. 63

Axioline potentials

Supply of communications power UL24 V DC
Current consumption from ULtyp. 105 mA (without I/Os and UL = 24 V)
max. 570 mA (with 2 A at UBus for the I/Os and UL = 24 V)
Communications power UBus5 V DC (via bus base module)
Current supply at UBus2 A

Digital inputs

Connection methodPush-in connection

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2701815-AXL F BK PNEnglish144 KbytesPHOENIX CONTACT-2701815-AXL F BK PN

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review