AXL F BK ETH XC 2701949 PHOENIX CONTACT Axioline F bus coupler for Ethernet, extreme conditions version (inc.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

AXL F BK ETH XC 2701949 PHOENIX CONTACT Axioline F bus coupler for Ethernet, extreme conditions version (inc..

AXL F BK ETH XC

2701949

PHOENIX_CONTACT

Available

Ship on today

Axioline F bus coupler for Ethernet, extreme conditions version (including bus base module and connectors)

More details


AUTOMATION Industrial Automation - PHOENIX CONTACT

I/O systems. Connectors - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+407,87 €
2+399,09 €
3+397,20 €
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Product description

The bus coupler represents the link between an Ethernet network (Modbus/TCP)and the Axioline F system.

Up to 63 Axioline F devices can be connected to an existing Ethernet system using the bus coupler.

Dimensions

Width45 mm
Height125.9 mm
Depth74 mm
Note on dimensionsThe depth is valid when a TH 35-7.5 DIN rail is used (according to EN 60715).

Ambient conditions

Ambient temperature (operation)-25 °C ... 60 °C (Standard; mounting position: wall mounting on horizontal DIN rail))
-25 °C ... 55 °C (Standard; mounting position: any)
-40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP20

Connection data

DesignationAxioline F connector
Connection methodPush-in connection
Note on connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Stripping length8 mm

General

Net weight177 g
Note on weight specificationswith connector and bus base module
Mounting typeDIN rail

Interfaces

Fieldbus systemEthernet
DesignationEthernet
Connection methodRJ45 socket, auto negotiation and auto crossing
Transmission speed10/100 MBit/s (Half or full duplex mode (automatic detection, can be adjusted manually))
Transmission physicsEthernet in RJ45 twisted pair
Fieldbus systemLokalbus
DesignationAxioline F local bus
Connection methodBus base module
Transmission speed100 MBit/s
DesignationService
Connection methodMicro USB type B

System limits of the bus coupler

Number of supported devicesmax. 63 (per station)
Number of local bus devices that can be connectedmax. 63

Axioline potentials

Supply of communications power UL24 V DC
Current consumption from ULtyp. 105 mA (without I/Os and UL = 24 V)
max. 583 mA (with 2 A at UBus for the I/Os and UL = 24 V)
Communications power UBus5 V DC (via bus base module)
Current supply at UBus2 A

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2701949-AXL F BK ETH XCEnglish145 KbytesPHOENIX CONTACT-2701949-AXL F BK ETH XC

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review