E5CC-RX3D5M-005 356266 OMRON Temperature and Process 3 Alarms Sal Universal Ent Relay 4 Evt 24Vdc / Vac 48x48 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

E5CC-RX3D5M-005 356266 OMRON Temperature and Process 3 Alarms Sal Universal Ent Relay 4 Evt 24Vdc / Vac 48x48

E5CC-RX3D5M-005

356266

OMRON

Available

Ship on today

Temperature and Process 3 Alarms Sal Universal Ent Relay 4 Evt 24Vdc / Vac 48x48

More details


Temperature Sensors

Temperature controllers - General purpose controllers - OMRON

Temperature controllers - General purpose controllers - E5_C - OMRON

* Brand new produt in its original packing covered by the warranties and certifications provided by OMRON

QuantityPrice
1+191,38 €
2+186,62 €
3+184,26 €
4+182,75 €
5+182,61 €
*This price is per unit and is the net value (not including taxes if applicable).


Related products

More info



E5_C General purpose temperature controllers
High performance & simplicity
The next generationE5_C temperaturecontroller is setting a new global standard in terms of precision and user-friendly design. Best control performance, easy set-up and outstanding visibility of the white IP66 LCD display have been integrated into a spac- ing-saving housing with only 60 mm of depth.
• Fast and precise regulation: 50 ms sampling loop period time
• Easy to set up, and operate intuitivelyvia CX-Thermo without power supply
• Best contrasty display using white LCD technology which is visible from a far distance and from any angle
• Useful alarm and diagnosis functions for secure operation
• Practical timer and logic operation functions eliminating the need of a PLC
Ordering information
E5CC (all models 3 auxiliary outputs)
Output Option No.Fixed option Order code
110-240VAC24 VAC/VDC
Out1: Relay
–– E5CC-RX3A5M-000 E5CC-RX3D5M-000
Out2: non
001Event input 2,
Heater burnout SSR defect detection
E5CC-RX3A5M-001 E5CC-RX3D5M-001
003Communication 3-phase heater alarm E5CC-RX3A5M-003 E5CC-RX3D5M-003
005Event input 4E5CC-RX3A5M-005 E5CC-RX3D5M-005
006Event input 2, Transfer output
007Event input 2, Remote SP
E5CC-RX3A5M-006 E5CC-RX3D5M-006
E5CC-RX3A5M-007 E5CC-RX3D5M-007
Out1: Voltage (pulse)
–– E5CC-QX3A5M-000E5CC-QX3D5M-000
Out2: non
001Event input 2,
Heater burnout SSR defect detection
E5CC-QX3A5M-001E5CC-QX3D5M-001
003Communication 3-phase heater alarm E5CC-QX3A5M-003E5CC-QX3D5M-003
005Event input 4E5CC-QX3A5M-005E5CC-QX3D5M-005
006Event input 2, Transfer output
007Event input 2, Remote SP
E5CC-QX3A5M-006E5CC-QX3D5M-006
E5CC-QX3A5M-007E5CC-QX3D5M-007
Out1: Voltage (pulse)
–– E5CC-QQ3A5M-000E5CC-QQ3D5M-000
Out2: Voltage (pulse)
001Event input 2,
Heater burnout SSR defect detection
E5CC-QQ3A5M-001E5CC-QQ3D5M-001
003Communication 3-phase heater alarm E5CC-QQ3A5M-003E5CC-QQ3D5M-003
005Event input 4E5CC-QQ3A5M-005E5CC-QQ3D5M-005
006Event input 2, Transfer output
007Event input 2, Remote SP
E5CC-QQ3A5M-006E5CC-QQ3D5M-006
E5CC-QQ3A5M-007E5CC-QQ3D5M-007
Out1: Linear current
–– E5CC-CX3A5M-000 E5CC-CX3D5M-000
Out2: non
004Event input 2, Communication
E5CC-CX3A5M-004 E5CC-CX3D5M-004
005Event input 4E5CC-CX3A5M-005 E5CC-CX3D5M-005
006Event input 2, Transfer output
007Event input 2, Remote SP
E5CC-CX3A5M-006 E5CC-CX3D5M-006
E5CC-CX3A5M-007 E5CC-CX3D5M-007
Out1: Linear current
–– E5CC-CQ3A5M-000 E5CC-CQ3D5M-000
Out2: Voltage (pulse)
001Event input 2,
Heater burnout SSR defect detection
E5CC-CQ3A5M-001 E5CC-CQ3D5M-001
003Communication 3-phase heater alarm E5CC-CQ3A5M-003 E5CC-CQ3D5M-003
005Event input 4E5CC-CQ3A5M-005 E5CC-CQ3D5M-005
006Event input 2, Transfer output
007Event input 2, Remote SP
E5CC-CQ3A5M-006 E5CC-CQ3D5M-006
E5CC-CQ3A5M-007 E5CC-CQ3D5M-007
Note:As well as these models other models are available on request. Please contact the local sales office for special requests.
521
E5_C General purpose temperature controllers
E5EC/E5AC (all models 4 auxiliary outputs)
Output Option No Fixed option Order code
110-240VAC24 VAC/VDC
Out1: Relay
–– E5_C-RX4A5M-000 E5_C-RX4D5M-000
Out2: non
009Event input 2,
Communication 3-phase heater alarm
010Event input 4,
Heater burnout SSR defect detection
011Event input 6,
Remote SP Heater burnout SSR defect detection, Transfer output
E5_C-RX4A5M-009 E5_C-RX4D5M-009
E5_C-RX4A5M-010 E5_C-RX4D5M-010
E5_C-RX4A5M-011 E5_C-RX4D5M-011
Out1: Voltage (pulse)
–– E5_C-QX4A5M-000E5_C-QX4D5M-000
Out2: non
009Event input 2,
Communication 3-phase heater alarm
010Event input 4,
Heater burnout SSR defect detection
011Event input 6,
Remote SP Heater burnout SSR defect detection, Transfer output
E5_C-QX4A5M-009E5_C-QX4D5M-009
E5_C-QX4A5M-010E5_C-QX4D5M-010
E5_C-QX4A5M-011E5_C-QX4D5M-011
Out1: Relay
–– E5_C-RR4A5M-000 E5_C-RR4D5M-000
Out2: Relay
009Event input 2,
Communication 3-phase heater alarm
010Event input 4,
Heater burnout SSR defect detection
011Event input 6,
Remote SP Heater burnout SSR defect detection, Transfer output
E5_C-RR4A5M-009 E5_C-RR4D5M-009
E5_C-RR4A5M-010 E5_C-RR4D5M-010
E5_C-RR4A5M-011 E5_C-RR4D5M-011
Out1: Voltage (pulse)
–– E5_C-QQ4A5M-000E5_C-QQ4D5M-000
Out2: Voltage (pulse)
009Event input 2,
Communication 3-phase heater alarm
010Event input 4,
Heater burnout SSR defect detection
011Event input 6,
Remote SP Heater burnout SSR defect detection, Transfer output
E5_C-QQ4A5M-009E5_C-QQ4D5M-009
E5_C-QQ4A5M-010E5_C-QQ4D5M-010
E5_C-QQ4A5M-011E5_C-QQ4D5M-011
Out1: Voltage (pulse)
–– E5_C-QR4A5M-000 E5_C-QR4D5M-000
Out2: Relay
009Event input 2,
Communication 3-phase heater alarm
010Event input 4,
Heater burnout SSR defect detection
011Event input 6,
Remote SP Heater burnout SSR defect detection, Transfer output
E5_C-QR4A5M-009 E5_C-QR4D5M-009
E5_C-QR4A5M-010 E5_C-QR4D5M-010
E5_C-QR4A5M-011 E5_C-QR4D5M-011
Out1: Linear current
–– E5_C-CX4A5M-000 E5_C-CX4D5M-000
Out2: non
004Event input 2, Communication
E5_C-CX4A5M-004 E5_C-CX4D5M-004
005Event input 4E5_C-CX4A5M-005 E5_C-CX4D5M-005
013Event input 6, Remote SP, Transfer output
014Event input 4, Communication Remote SP, Transfer output
E5_C-CX4A5M-013 E5_C-CX4D5M-013
E5_C-CX4A5M-014 E5_C-CX4D5M-014
Out1: Linear current
–– E5_C-CC4A5M-000 E5_C-CC4D5M-000
Out2: Linear current
004Event input 2, Communication
E5_C-CC4A5M-004 E5_C-CC4D5M-004
005Event input 4E5_C-CC4A5M-005 E5_C-CC4D5M-005
013Event input 6,
Remote SP Transfer output
014Event input 4, Communication Remote SP, Transfer output
E5_C-CC4A5M-013 E5_C-CC4D5M-013
E5_C-CC4A5M-014 E5_C-CC4D5M-014
Out1: Linear current
–– E5_C-CQ4A5M-000E5_C-CQ4D5M-000
Out2: Voltage (pulse)
009Event input 2,
Communication 3-phase heater alarm
010Event input 4,
Heater burnout SSR defect detection
011Event input 6,
Remote SP Heater burnout SSR defect detection, Transfer output
E5_C-CQ4A5M-009E5_C-CQ4D5M-009
E5_C-CQ4A5M-010E5_C-CQ4D5M-010
E5_C-CQ4A5M-011E5_C-CQ4D5M-011
Out1: Relay*1
–– E5_C-PR4A5M-000 E5_C-PR4D5M-000
Out2: Relay*1
004Event input 2, Communication
014Event input 4, Communication Remote SP, Transfer output
E5_C-PR4A5M-004 E5_C-PR4D5M-004
E5_C-PR4A5M-014 E5_C-PR4D5M-014
*1Position proportional control model
522
E5_C General purpose temperature controllers
E5GC (models with 0, 1 or 2 auxiliary outputs)
Output Terminal typeOption No Fixed option Order code
110-240VAC24 VAC/VDC
Out 1: RelayScrew terminals
(with cover)
––E5GC-RXOA6M-OOO E5GC-RXOD6M-OOO E5GC-RX1A6M-OOO E5GC-RX106M-OOO E5GC-RX2A6M-OOOE5GC-RX206M-OOO
015CommunicationE5GC-RX1A6M-015 E5GC-RX106M-015
E5GC-RX2A6M-015 E5GC-RX206M-015
016Event input 1E5GC-RX2A6M-016 E5GC-RX206M-016
023Heater Burnout SSR defect detectionE5GC-RX2A6M-023 E5GC-RX206M-023
024Event input 2E5GC-RX1A6M-024 E5GC-RX106M-024
Screwless clamp terminal ––E5GC-RXOACM-OOO E5GC-RXODCM-OOO E5GC-RX1ACM-OOO E5GC-RX1DCM-OOO E5GC-RX2ACM-OOOESGC-RX2DCM-OOO
015CommunicationE5GC-RX1ACM-015 E5GC-RX1DCM-015
ESGC-RX2ACM-015E5GC-RX2DCM-015
016Event input 1ESGC-RX2ACM-016ESGC-RXZDCM-016
023Heater Burnout SSR defect detectionESGC-RX2ACM-023ESGC-RXZDCM-023
024Event input 2ESGC-RX1ACM-024ESGC-RX1DCM-024
Out 1: Voltage (pulse) Screw terminals
(with cover)
––E5GC-OXOA6M-OOOE5GC-OXOD6M-OOO E5GC-OX1A6M-OOO E5GC-OX106M-OOO E5GC-OX2A6M-OOO E5GC-OX206M-OOO
015CommunicationE5GC-OX1A6M-015E5GC-OX106M-015
E5GC-OX2A6M-015E5GC-OX206M-015
016Event input 1E5GC-OX2A6M-016E5GC-OX206M-016
023Heater Burnout SSR defect detectionE5GC-OX2A6M-023E5GC-OX206M-023
024Event input 2E5GC-OX1A6M-024E5GC-OX106M-024
Screwless clamp terminal ––E5GC-OXOACM-OOOE5GC-OXODCM-OOO E5GC-OX1ACM-OOOE5GC-OX1DCM-OOO ESGC-OX2ACM-OOO ESGC-OX2DCM-OOO
015CommunicationE5GC-OX1ACM-015E5GC-OX1DCM-015
E5GC-OX2ACM-015E5GC-OX2DCM-015
016Event input 1ESGC-OX2ACM-016 ESGC-OX2DCM-016
023Heater Burnout SSR defect detectionESGC-OX2ACM-023 ESGC-OX2DCM-023
024Event input 2ESGC-OX1ACM-024 ESGC-OX1DCM-024
Out 1: Liner currentScrew terminals
(with cover)
––E5GC-CXOA6M-OOO E5GC-CXOD6M-OOO E5GC-CX1A6M-OOO E5GC-CX106M-OOO E5GC-CX2A6M-OOO E5GC-CX206M-OOO
015CommunicationE5GC-CX1A6M-015 E5GC-CX106M-015
E5GC-CX2A6M-015 E5GC-CX206M-015
016Event input 1E5GC-CX2A6M-016 E5GC-CX206M-016
024Event input 2E5GC-CX1A6M-024 E5GC-CX106M-024
Screwless clamp terminal ––ESGC-CXOACM-000 ESGC-CXODCM-000
E5GC-CX1ACM-OOO E5GC-CX10CM-OOO E5GC-CX2ACM-OOO E5GC-CX20CM-OOO
015CommunicationE5GC-CX1ACM-015 E5GC-CX10CM-015
E5GC-CX2ACM-015 E5GC-CX20CM-015
016Event input 1E5GC-CX2ACM-016 E5GC-CX20CM-016
024Event input 2E5GC-CX1ACM-024 E5GC-CX10CM-024
E5DC (models with 0 or 2 auxiliary outputs)
Output Option No Fixed option Order code
110-240VAC24 VAC/VDC
Out1: Relay–– E5DC-RX2ASM-000E5DC-RX2DSM-000
002Communication,
Heater Burnout SSR defect detection
E5DC-RX2ASM-002E5DC-RX2DSM-002
015Communication E5DC-RX0ASM-015*1
E5DC-RX0DSM-015*1
017Event Input 1,
Heater Burnout SSR defect detection
E5DC-RX2ASM-017E5DC-RX2DSM-017
Out1: Voltage (pulse)–– E5DC-QX2ASM-000 E5DC-QX2DSM-000
002Communication,
Heater Burnout SSR defect detection
E5DC-QX2ASM-002 E5DC-QX2DSM-002
015Communication E5DC-QX0ASM-015*1E5DC-QX0DSM-015*1
017Event Input 1,
Heater Burnout SSR defect detection
E5DC-QX2ASM-017 E5DC-QX2DSM-017
Out1: Linear curent –– E5DC-CX2ASM-000 E5DC-CX2DSM-000
015Communication E5DC-CX0ASM-015*1 E5DC-CX0DSM-015*1
015Communication E5DC-CX2ASM-015 E5DC-CX2DSM-015
016Event Input 1E5DC-CX2ASM-016 E5DC-CX2DSM-016
*1Auxiliary outputs are not possible for these models.
523
E5_C General purpose temperature controllers
E5_C optional tools
Option Order code
USB based configuration cable E58-CIFQ2, E58-CIFQ2-E (for E5AC, E5DC, E5EC and E5GC) PC based configuration and tuning softwareEST2-2C-MV4
Specifications
E5CC/E5EC/E5AC
Item E5CCE5ECE5AC Power supply voltageA in model number: 100 to 240VAC, 50/60 Hz
D in model number: 24 VAC, 50/60Hz 24 VDC
Operating voltage range85% to 110% of rated supply voltage
Power consumption 6.5 VA max. at 100 to 240VAC, and
4.1 VA max. at 24 VAC or
2.3 W max. at 24 VDC
Sensor input •Temperature inputs
8.3 VA max. at 100 to 240VAC, and
5.5 VA max. at 24 VAC or
3.2 W max. at 24 VDC
9.0VA max. at 100 to 240VAC, and
5.6VA max. at 24 VAC or
3.4 W max. at 24 VDC
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II Platinum resistance thermometer: Pt100 or JPt100
Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C
•Analog inputs
Current input (mA): 4 to 20 or 0 to 20
Voltage input (V): 1 to 5, 0 to 5, or 0 to 10
Input impedanceCurrent input: 150  max., Voltage input: 1 M min.
(Use a 1:1 connection when connecting the ES2-HB/THB.)
Control methodON/OFF controlor 2-PID control (with auto-tuning)
Indication accuracy Thermocouple input: (±0.3% of indicatedThermocouple input: (±0.3% of indicated value or ±1°C, whicheveris greater)
value or ±1°C, whichever is greater)
±1 digit max.
Platinum resistance thermometer input: (±0.2% of indicated value or ±0.8°C,
whichever is greater) ±1 digit max. Analog input:±0.2%FS ±1 digit max.
CT input: ±5%FS ±1 digit max.
±1 digit max.
Platinum resistance thermometer input: (±0.2% of indicated value or ±0.8°C, which- ever is greater) ±1 digit max.
Analoginput:±0.2%FS ±1 digit max. CT input:±5% FS ±1 digit max. Potentiometer input: ±5% FS ±1 digit max.
Auto-TuningYes, 40%/100% MV output limit selection. When using Heat/Cool: Automatic cool gain adjustment
Self-TuningYes
Control outputs Relay outputSPST-NO,250VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA
SPST-NO,250VAC, 5 A (resistive load), electricallife: 100,000 operations, minimum applicable load: 5 V, 10 mA
Voltage output (for driving SSR)Output voltage: 12 VDC ±20% (PNP), max. Output voltage: 12 VDC ±20% (PNP),
load current: 21 mA, with short-circuit protection circuit
max. load current: 40 mA, with short-circuit protection circuit
(The maximum load current is 21 mA for models with two control outputs.)
Linear current output 4 to 20 mA DC/0 to 20 mA DC, load: 500  max., resolution: approx. 10,000
Auxiliary outputs Number of outputs34
Output specificationsN.O. relay outputs, 250 VAC,
Models with 3 outputs: 2 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA
Event inputsNumber of inputs2 or 4 or 6 max (depends on the model)
N.O. relay outputs, 250 VAC,
Models with 4 outputs: 2 A (resistive load), electricallife: 100,000 operations, minimum applicable load: 5 V, 10 mA
External contact input specificationsContact input: ON: 1 k max., OFF: 100 k min.
Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max. Current flow: approx. 7 mA per contact
Setting methodDigital setting using front panel keys or via Remote Software CX-Thermo V4.5
Indication method11-segment digital display and individual indicators
Multi SP Up to eight set points (SP0 to SP7) can be saved and selected using event inputs, key operations, or serial communications.
Other functionsManual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout detection (includ- ing SSR failure detection), 40%AT, 100% AT, MV limiter, input digital filter, self-tuning, temperature input shift, run/stop, pro- tection functions, extraction of square root, MV change rate limit, logic operations,PV/SV status display, simple program, automatic cooling coefficient adjustment
Ambient operating temperature–10 to 55°C (with no condensation or icing)
Ambient operating humidity 25% to 85%
Storage temperature–25 to 65°C (with no condensation or icing)
Degree of protectionFront panel: IP66, Rear case: IP20, Terminals: IP00
Sampling period50 ms
Size in mm (H×W×D)48×48×6448×96×6496×96×64
524
E5_C General purpose temperature controllers
E5GC
Item E5GC
Power supply voltageA in model number: 100 to 240VAC, 50/60 Hz
D in model number: 24VAC, 50/60Hz 24 VDC
Sensor input •Temperature input
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II Platinum resistance thermometer: Pt100 or JPt100
Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C
•Analog input
Current input: 4 to 20 mA or 0 to 20 mA Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
Control methodON/OFF control or 2-PID control(with auto-tuning)
Control output Relay outputSPST-NO, 250 VAC, 2 A (resistive load), electricallife: 100,000 operations, minimum applicable load: 5 V, 10 mA (reference value)
Voltage output (for driving SSR)Output voltage 12 VDC ±20% (PNP), max. Load current: 21 mA, with short-circuit protection circuit
Linear current output 4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: Approx. 10,000
Auxiliary output Number of outputs1 or 2 (depends on model)
Output specificationsSPST-NO relay outputs, 250VAC, 2 A (resistive load),
Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V (reference value)
Indication method11-segment digital displays and individual indicators
Character height: PV: 10.5mm,SV: 5.0 mm
Multi SP Up to eight set points(SP0 to SP7) can be saved and selected using the event inputs, key operations, or serial communications.*1
Other functionsManual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout (HB) alarm (includ- ing SSR failure(HS) alarm),40% AT, 100% AT, MV limiter, input digital filter, self tuning, robust tuning, PV input shift, run/stop, protection functions, extraction of square root, MV change rate limit, logic operations, temperature status display, simple pro-
gramming, moving average of input value, display brightness setting, simple transfer output, and work bit message.*2
Size in mm (H×W×D)24×48×93
*1Only four set points are selectable for event inputs.
*2Simple transfer output and work bit message are only for E5GC.
E5DC
Item E5DC
Power supply voltageA in model number: 100 to 240VAC, 50/60 Hz
D in model number: 24VAC, 50/60Hz 24 VDC
Operating voltage range85% to 110% of rated supply voltage
Power consumption 4.9VA max. at 100 to 240VAC, and
2.8VA max. at 24 VDC or
1.5 W max. at 24 VDC
Sensor input •Temperature inputs
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II Platinum resistance thermometer: Pt100 or JPt100
Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C
•Analog inputs
Current input (mA): 4 to 20 or 0 to 20
Voltage input (V): 1 to 5, 0 to 5, or 0 to 10
Input impedanceCurrent input: 150  max., Voltage input: 1 M min. (Use a 1:1 connection when connecting the ES2-HB/THB.)
Control methodON/OFF control or 2-PID control(with auto-tuning)
Indication accuracy Thermocouple input: (±0.3% of PV or ±1°C, whichever is greater) ±1 digit max.
Platinum resistance thermometer input: (±0.2% of PV or ±0.8°C, whichever is greater) ±1 digit max. Analog input: ±0.2% FS ±1 digit max.
CT input: ±5% FS ±1 digit max.
Auto-Tuning Yes, 40%/100% MV output limit selection. When using Heat/Cool: Automatic cool gain adjustment
Self-Tuning Yes
Control outputs Relay outputSPST-NO,250VAC, 3 A (resistiveload), electricallife: 100,000 operations, minimum applicable load: 5 V, 10 mA
Voltage output (for driving SSR)Output voltage: 12 VDC ±20%(PNP), max. load current: 20 mA, with short-circuit protection circuit
Linear current output 4 to 20 mA DC/0 to 20 mA DC, load:500  max., resolution: approx. 10,000
Auxiliary outputs Number of outputs2 (depends on model)
Output specificationsSPST-NO relay outputs: 250VAC, 2 A (resistive load),
Electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA
Event inputsNumber of inputs1 (depends on model)
External contact input specificationsContact input: ON: 1 k max., OFF: 100 k min.
Non-contact input: ON: Residualvoltage: 1.5 V max., OFF: Leakage current: 0.1 mA max. Current flow: approx. 7 mA per contact
Setting methodDigital setting using front panel keys
Indication method11-segment digital displays and individual indicators
Character height: PV 8.5 mm,SV: 8.0 mm
Multi SP Up to eight set points (SP0 to SP7) can be saved and selected using event inputs, key operations, or serial communications.*1
Other functionsManual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout (HB) alarm (includ- ing SSR failure(HB) alarm), 40% AT, 100% AT, MV limiter, input digital filter, self tuning, robust tuning, PV input shift, run/stop, protection functions, extraction of square root, MV change rate limit, simple calculations, temperature status display, simple pro- gramming, moving average of input value, and display brightness setting
Ambient operating temperature–10 to 55°C (with no condensation or icing), for 3-year warranty: –10 to 50°C (with no condensation or icing)
Ambient operating humidity 25% to 85%
Storage temperature–25 to 65°C (with no condensation or icing)
Degree of protectionMain unit: IP20, Terminal unit: IP00
Sampling period50 ms
Size in mm (H×W×D)96×22.5×85
*1Only two set points are selectable for event inputs.
525
E5_C General purpose temperature controllers
USB communication cable E58-CIFQ2
Item E5AC E5CCE5DCE5EC E5GC E58-CIFQ2    E58-CIFQ2-E – 
E58-CIFQ2
E58-CIFQ2-E
Exchange this head for
E5AC/E5DC/E5EC/E5GC adaptation.
526

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoTemperature controller, 1/16DIN 48 x 48mm, 1 x relay output, 3 x auxiliary r - OMRON - E5CC-RX3D5English287 Kbytespdf1-mostradoTemperature controller, 1/16DIN 48 x 48mm, 1 x relay output, 3 x auxiliary r - OMRON - E5CC-RX3D5

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review