OS32C-WIN-KT 349191 OMRON Security Product, OS32C scanner replacement window View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

OS32C-WIN-KT 349191 OMRON Security Product, OS32C scanner replacement window

OS32C-WIN-KT

349191

OMRON

Available

Ship on today

Security Product, OS32C scanner replacement window

More details


Safety

Safety

OS32C

* Brand new produt in its original packing covered by the warranties and certifications provided by OMRON

*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



OS32C Safety sensors
OS32C Safety laser scanner
• Type 3 safety laser scanner complies with IEC61496-1/-3
• 70 sets of safety zone and warning zone combinations are available, supporting complicated changes in working environments
•A safety radius up to 4 m and warning zone(s) radius up to 10 m can be set
• 8 Individual sector indicators and various LED indications allow the user to determine scanner status at a glance
• Reference boundary monitoring function prevents unauthorized changes in the scanner position
• Configurable minimum object resolution of 30, 40, 50 or 70 mm, for hand and arm detection applications
Ordering information
Description Max. operating rangeOrder code
Description Remarks Order code
OS32C with back location cable entry 3 mOS32C-BP
4mOS32C-BP-4M
Configuration toolCD-ROM
OS supported:
included
OS32C with side location cable entry*1
OS32C with back location cable entry EtherNet/IP capable for status measure- ment data reporting
OS32C with side location cable entry*1
EtherNet/IP capable for status measure- ment data reporting
3mOS32C-SP1
4mOS32C-SP1-4M
3mOS32C-BP-DM
4mOS32C-BP-DM-4M
3mOS32C-SP1-DM
4mOS32C-SP1-DM-4M
Windows 2000, XP, Vista, Windows 7
*1Each connector is located on the left as viewed from the back of the I/O block.
Specifications
Sensors
Sensor typeType 3 safety laser scanner
Safety categoryCategory 3, performance level d (ISO13849-1: 2006)
Detection capabilityConfigurable Non-transparent with a diameter of 30, 40, 50 or 70 mm (1.8% reflectivity or greater)
Monitoring zoneMonitoring zone set count: (Safety zone + 2 warning zones) × 70 sets
Operating rangeSafety Zone: 4.0 m (min. obj. resolution of 70mm, only OS32C-_-4M types)
3.0 m (min. obj. resolution of 50 mm or 70 mm)
2.5 m (min. obj. resolution of 40 mm)
1.75 m (min. obj. resolution of 30 mm) Warning Zone:10.0 m (15.0 m for OS32C-_-4M types)
Detection angle 270°
Response time Response time from ON to OFF: From80 ms (2 scans)to 680 ms (up to 17 scans)*1
Response time from OFF to ON: Response time from ON to OFF + 100 ms to 60 s (configurable)
Line voltage 24 VDC +25%/–30% (ripple p-p 2.5 V max.)
Power consumption Normal operation: 5 W max., 4 W typical (withoutoutput load)*2
Standbymode: 3.75 W (without output load)
Safety output (OSSD) PNP transistor × 2, load current of 250mA max., residual voltage of 2 V max., load capacity of 2.2 μf max., leak current of 1 mA max.*2,*3,*4
Auxiliary output (Non-safety) NPN/PNP transistor × 1, load current of 100 mA max., residual voltage of 2 V max., leak current of 1 mA max.*3,*4,*5
Warning output (Non-safety) NPN/PNP transistor × 1, load current of 100 mA max., residual voltage of 2 V max., leak current of 1 mA max.*3,*4,*5
Output operation mode Auto start, start interlock, start/restart interlock
Input External Device Monitoring (EDM) ON: 0 V short (input current of 50 mA), OFF: Open Start ON: 0 V short (input current of 20 mA), OFF: Open Zone selectON: 24 V short (input current of 5 mA), OFF: Open Stand-byON: 24 V short (input current of 5 mA), OFF: Open
Connection typePower cable: 18-pin mini-connector (pigtail) Communication cable: M12, 4-pin connector
Connection with PC Communication:EtherNet/IP
Indicators RUN indicator: Green, STOP indicator:Red, Interlock indicator:Yellow, Warning output indicator: Orange, Status/diagnostic display: 2 × 7-segment LEDs, Intrusion indicators: Red LED × 8
Enclosure rating IP65 (IEC60529)
Dimensions (W × H × D)133.0 × 104.5 × 142.7 mm (except cable)
Weight (Main Unit only)1.3 kg
ApprovalsCertified by: TÜV Rheinland, UL
Major standards: IEC61496-1/-3 (Type 3), IEC61508 (SIL2), ISO13849-1:2008 (Category 3, performance level d), UL508, UL1998
*1Pollution Tolerance will add 6 ms to each scan time.
*2Rated current of OS32C is 1.025A max.(OS32C 210 mA + OSSD A load+ OSSD B load+ auxiliary output load + warning output load + functional Inputs). Where functional inputs are: EDM input ... 50 mA, Start input ... 20 mA, Standby input ... 5 mA, Zone X input ... 5 mA × 8 (eight zone set select inputs).
*3Output voltage is input voltage – 2.0 VDC.
*4Total consumption current of 2 OSSDs, auxiliary output, and warning output must not exceed 700 mA.
*5Output polarity (NPN/PNP) is configurable via the configuration tool.
489
OS32C Safety sensors
Accessories (sold separately)
Power cable
Appearance DescriptionRemarksOrder code
Cable length: 3 mOne cable is required per sensor OS32C-CBL-03M Cable length: 10 m OS32C-CBL-10M Cable length: 20 m OS32C-CBL-20M
Cable length: 30 m OS32C-CBL-30M
Ethernet cable
Appearance DescriptionRemarksOrder code
Cable length: 2 mRequired for configuration and monitoringOS32C-ECBL-02M Cable length: 5 m OS32C-ECBL-05M
Cable length: 15 m OS32C-ECBL-15M
Note: An ethernet cable with an M12, 4-pin connector is required.
Mounting brackets
Appearance DescriptionRemarksOrder code
Bottom/side mounting bracket Bottom/side mounting bracket × 1, unit mounting screws × 4 sets
OS32C-BKT1
XY axis rotation mounting bracketXY axis rotation mounting bracket × 1, unit mounting screws × 6 sets,
bracket mounting screws × 1 set
(must be used with OS32C-BKT1)
OS32C-BKT2
Simple mounting bracket Simple mounting brackets × 2, unit mounting screws × 4 sets*1
OS32C-BKT3
Protective cover for window OS32C-BKT4
Mounting standWhen using a mounting stand, use an OS32C
with side location cable entry (OS32C-SP1).
The OS32C with back location cable entry (OS32C-BP)
cannot be mounted.
Use with mounting brackets (OS32C-BKT1 and OS32C-BKT2).
OS32C-MT
Hardware kit for mounting stand Mounting screws × 3 sets
Use this when mounting a bracket to the mounting stand.
OS32C-HDT
*1There are eight OS32C mounting screws: four screws for singular use, and four screws for protective cover for window.
490
OS32C Safety sensors
Miscellaneous
Appearance DescriptionRemarksOrder code
Scan window Spare for replacementOS32C-WIN-KT
Sensor block without I/O block
Max. operating range: 3 m
Spare for replacementOS32C-SN
Sensor block without I/O block
Max. operating range: 4 m
OS32C-SN-4M
Sensor block without I/O block for EtherNet/IP Max. operating range: 3 m
Spare replacement for EtherNet/IP OS32C-SN-DM
Sensor block without I/O block for EtherNet/IP Max. operating range: 4 m
OS32C-SN-DM-4M
I/O blockWith cable access from the back
Spare for replacementOS32C-CBBP
With cable access from the left side
Spare for replacementOS32C-CBSP1
Window cleaning kit, anti-static cleanerAccessoryWIN-CLN-KT
Connection
Basic connection with single OS32C unit
Category 3, performance level d (ISO13849-1)
Functional earth (Green)
24 VDC (White)
0 VDC (Brown)
Standby input (Violet)
Zone select 1 (Orange/White) Zone select 2 (Orange/Black) Zone select 3 (Gray)
Zone select 4 (Pink)
Zone select 5 (White/Black) Zone select 6 (Tan)
Zone select 7 (Orange)
Zone select 8 (Blue/White) Start (Black)
Auxiliary output (Blue)
Warning output (Red/Black) EDM (Brown/White)
Safety output B (Yellow) Safety output A (Red)
PE
0V
S3
*4 S2
*4 S2
*4 S2
*4 S2
*4 S2
*4 S2
*4 S2
*4 S2
*3S1
*2ED1ED2
ED1
*1
ED2
*1
E1
+24V
ED1
ED2
M1
S1 : Start input
S2 : Zone select switch
S3 : Standby switch
ED1, ED2: Forcedguided relay
M1 : 3-Phasemotor
E1 : 24 VDC Power
OS32C configuration
– External Device Monitoringenabled
– Start/restart interlock
*1.External devices (ED1, ED2) are forced guide relays.(G7Z, G7SA, G7S, etc)
*2.If the External Device Monitoring is not used, connect brown/white wires to 0 V, and then turn OFF the
External Device Monitoring with the configuration software.
*3.Use NC-contact for a start input.
*4.For zone select switch setting, refer to OS32C Series user'smanual.
Note:This wiring exampleis for category3.
491

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoSafety laser scanner, replacement scan window - OMRON - OS32C-WIN-KT - 349191English263 Kbytespdf1-mostradoSafety laser scanner, replacement scan window - OMRON - OS32C-WIN-KT - 349191
pdf2-mostradoSafety laser scanner, replacement scan window - OMRON - OS32C-WIN-KT - 349191English632 Kbytespdf1-mostradoSafety laser scanner, replacement scan window - OMRON - OS32C-WIN-KT - 349191

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review