FQ-VP1010 372156 FQ 3403F OMRON Vision System, Parallel Cable FQ-SDU1 10m View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

FQ-VP1010 372156 FQ 3403F OMRON Vision System, Parallel Cable FQ-SDU1 10m

FQ-VP1010

372156

FQ 3403F

OMRON

Available

Ship on today

Vision System, Parallel Cable FQ-SDU1 10m

More details


FQ

* Brand new product in its original packaging covered by the warranties and certifications provided by OMRON

Quantity Price
1+$216.56
2+$208.84
4+$202.82
5+$201.18
7+$199.75
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



FQ2 Inspection systems
The new standard in image inspection and code verification
System Configuration
The FQ2 vision sensorfamily is set to redefine the vision sensor market, providing
advanced inspection, code reading and verification only previously available in higher end vision systems. With over 100 camera options, the FQ2 providesuserswiththe
ultimateflexibility to solve applications, whetheryou need high resolution, code
reading, integratedlighting, or a cost effective solution to solve a simple application, there is an FQ2 whichfits your needs.
• Powerful functionality with versatile line-up
• All-in-one-housing
• Easy searchingwith Shape Search II
• Direct Part Marked (DPM)
• Unique OCR technology
• Code verification
Up to 32 Sensors can be set up and monitored from a single Touch Finder or PC Tool. Various types of Sensors can be used at the same time.
However, I/O type and wiring method vary depending on the Sensor, so select the necessary devices.
Sensors (32 max.)*
FQ2-S1/S2/S3/S4/CH,FQ-CR1/CR2
Touch Finder FQ2-D
or PC Tool
Standard Ethernet Cable
RJ-45 of the FCC regulations
Switching Hub
W4S1
Special Ethernet Cable
FQ-WN
*The Setup Tool can connect to up to 32 Sensors and it can display up to eight Sensors at the same time.
Note: If you register as a member after purchasing a Sensor, you can download free setup software that runs on a PC and can be used in place of Touch Finder.
Refer to the member registration sheet for details.
Ethernet (EtherNet/IP, No-protocol, or PLC Link) Connection
FQ2-S1 FQ2-S2
FQ2-S3FQ2-S4
FQ2-CHFQ-CR1
Touch Finder
FQ2-D
or PC Tool
Switching Hub
W4S1
ControlPLC
FQ-CR2
Standard
Ethernet Cable*
DC24V
Standard Ethernet Cable*
Sensor
FQ2-S1/S2/S3/S4/CH,FQ-CR1/CR2
Trigger sensor
I/O controlPLC
* RJ-45 of the FCC regulations
FQ
Ethernet Cable
FQ-WN
I/O Cable
FQ-WD
FL-STC
Lighting Controller
DC24V
FL-series
External Lighting
Parallel Interface Connection
Connection with Standard Parallel Interface of the Sensor
FQ2-S1 FQ2-S2
FQ2-S3FQ2-S4
FQ2-CHFQ-CR1
Touch Finder
FQ2-D
or PC Tool
FQ
Ethernet Cable
FQ-WN
Sensor
FQ2-S1/S2/S3/S4/CH,FQ-CR1/CR2
I/O Cable
FQ-WD
Trigger sensor
FL-STC
Lighting Controller
Sensor control PLC I/O control PLC
FL-series
External Lighting
FQ-CR2
DC24V
DC24V
Connection through a Parallel Interface Sensor Data Unit
FQ2-S1 FQ2-S2
FQ2-S3FQ2-S4
FQ2-CHFQ-CR1
Touch Finder
FQ2-D
or PC Tool
FQ
Ethernet Cable
FQ-WN
Sensor
FQ2-S3/S4/CH
Sensor Data Unit Cable FQ-WU
Parallel Interface Sensor Data Unit FQ-SDU1
Parallel Cable for FQ-SDU1
Trigger sensor
FL-STC
Sensor control PLC I/O control PLC
FL-series
FQ-CR2
DC24V
FQ-VP1
x 2 cables
Lighting Controller
DC24V
External Lighting
315
FQ2 Inspection systems
RS-232C Serial Connection
FQ2-S1 FQ2-S2
FQ2-S3FQ2-S4
FQ2-CHFQ-CR1
FQ-CR2
Touch Finder
FQ2-D
or PC Tool
FQ
Ethernet Cable
FQ-WN
Sensor
FQ2-S3/S4/CH
RS-232C Interface Sensor Data Unit FQ-SDU2
Sensor Data Unit Cable FQ-WU
Parallel Cable for
FQ-SDU2
FQ-VP2 x 2 cables
RS-232C Cable
XW2Z- @00S-V
Trigger sensor
Sensor control PLC I/O controlPLC
Model compatible with communications interface
Compatible
Not compatible
DC24V
FL-STC
Lighting Controller
Sensor control PLC DC24V
FL-series
External Lighting
Ordering Information
Sensor
Inspection model
FQ2-S1 Series [Single-function Type]
Field of visionNarrow ViewStandard View Wide View (Long-distance) Wide View (Short-distance)
Number of pixels 350,000 pixels
Color NPNFQ2-S10010F FQ2-S10050F FQ2-S10100F FQ2-S10100N PNPFQ2-S15010FFQ2-S15050FFQ2-S15100FFQ2-S15100N
Field of vision/Installation distanceRefer to Figure 1 on page 317. Refer to Figure 2 on page 317. Refer to Figure 3 on page 317. Refer to Figure 4 on page 317.
FQ2-S2 Series [Standard Type]
Field of visionNarrow ViewStandard View Wide View (Long-distance) Wide View (Short-distance)
Number of pixels 350,000 pixels
Color NPNFQ2-S20010F FQ2-S20050F FQ2-S20100F FQ2-S20100N PNPFQ2-S25010FFQ2-S25050FFQ2-S25100FFQ2-S25100N
Field of vision/Installation distanceRefer to Figure 1 on page 317. Refer to Figure 2 on page 317. Refer to Figure 3 on page 317. Refer to Figure 4 on page 317.
FQ2-S3 Series [High-resolution Type]
Field of visionNarrow ViewStandard View Wide View (Long-distance) Wide View (Short-distance) C-mount Number of pixels 760,000 pixels 1.3 million pixels Color NPNFQ2-S30010F-08 FQ2-S30050F-08 FQ2-S30100F-08 FQ2-S30100N-08FQ2-S30-13
PNPFQ2-S35010F-08FQ2-S35050F-08FQ2-S350100F-08FQ2-S35100N-08 FQ2-S35-13
MonochromeNPNFQ2-S30010F-08M FQ2-S30050F-08M FQ2-S30100F-08M FQ2-S30100N-08MFQ2-S30-13M PNPFQ2-S35010F-08M FQ2-S35050F-08M FQ2-S35100F-08M FQ2-S35100N-08MFQ2-S35-13M
Field of vision/Installation distanceRefer to Figure 5 on page 317. Refer to Figure 6 on page 317. Refer to Figure 7 on page 317. Refer to Figure 8 on page 317. Refer to optical chart on p. 318
Inspection/ID model
FQ2-S4 Series [Standard Type]
Field of visionNarrow ViewStandard View Wide View (Long-distance) Wide View (Short-distance)
Number of pixels 350,000 pixels
Color NPNFQ2-S40010F FQ2-S40050F FQ2-S40100F FQ2-S40100N PNPFQ2-S45010FFQ2-S45050FFQ2-S45100FFQ2-S45100N
MonochromeNPNFQ2-S40010F-M FQ2-S40050F-MFQ2-S40100F-M FQ2-S40100N-M PNPFQ2-S45010F-M FQ2-S45050F-MFQ2-S45100F-M FQ2-S45100N-M
Field of vision/Installation distanceRefer to Figure 1 on page 317. Refer to Figure 2 on page 317. Refer to Figure 3 on page 317. Refer to Figure 4 on page 317.
[High-resolution Type]
Field of visionNarrow ViewStandard View Wide View (Long-distance) Wide View (Short-distance) C-mount Number of pixels 760,000 pixels 1.3 million pixels Color NPNFQ2-S40010F-08 FQ2-S40050F-08 FQ2-S40100F-08 FQ2-S40100N-08FQ2-S40-13
PNPFQ2-S45010F-08FQ2-S45050F-08FQ2-S45100F-08FQ2-S45100N-08 FQ2-S45-13
MonochromeNPNFQ2-S40010F-08M FQ2-S40050F-08M FQ2-S40100F-08M FQ2-S40100N-08MFQ2-S40-13M PNPFQ2-S45010F-08M FQ2-S45050F-08M FQ2-S45100F-08M FQ2-S45100N-08MFQ2-S45-13M
Field of vision/Installation distanceRefer to Figure 5 on page 317. Refer to Figure 6 on page 317. Refer to Figure 7 on page 317. Refer to Figure 8 on page 317. Refer to optical chart on p. 318
316
FQ2 Inspection systems
ID Model
FQ2-CH Series [Optical Character Recognition Sensor]
Field of visionNarrow View Standard ViewWide View (Long-distance)Wide View (Short-distance)
Number of pixels 350,000 pixels
MonochromeNPNFQ2-CH10010F-M FQ2-CH10050F-M FQ2-CH10100F-M FQ2-CH10100N-M PNPFQ2-CH15010F-M FQ2-CH15050F-M FQ2-CH15100F-M FQ2-CH15100N-M
Field of vision/Installation distance Refer to Figure 1 on page 317. Refer to Figure 2 on page 317. Refer to Figure 3 on page 317. Refer to Figure 4 on page 317.
FQ-CR1 Series[Multi Code Reader]
Field of visionNarrow View Standard ViewWide View (Long-distance)Wide View (Short-distance)
Number of pixels 350,000 pixels
MonochromeNPNFQ-CR10010F-MFQ-CR10050F-MFQ-CR10100F-MFQ-CR10100N-M PNPFQ-CR15010F-MFQ-CR15050F-MFQ-CR15100F-MFQ-CR15100N-M
Field of vision/Installation distance Refer to Figure 1 on page 317. Refer to Figure 2 on page 317. Refer to Figure 3 on page 317. Refer to Figure 4 on page 317.
FQ-CR2 Series[2D Code Reader]
Field of visionNarrow View Standard ViewWide View (Long-distance)Wide View (Short-distance)
Number of pixels 350,000 pixels
MonochromeNPNFQ-CR20010F-MFQ-CR20050F-MFQ-CR20100F-MFQ-CR20100N-M PNPFQ-CR25010F-MFQ-CR25050F-MFQ-CR25100F-MFQ-CR25100N-M
Field of vision/Installation distance Refer to Figure 1 on page 317. Refer to Figure 2 on page 317. Refer to Figure 3 on page 317. Refer to Figure 4 on page 317.
Field of vision/Installation distance(Unit: mm) Field of vision Narrow ViewStandard ViewWide View (Long-distance)Wide View (Short-distance) Appearance
350,000 pixels type Figure 1 Figure 2 Figure 3 Figure 4
38
574.7
8.2
7.5
Field of vision
13
56
215
8.2
13
Field of vision
220
3353
Field of vision
32
18
380
29
Field of vision
33 53
970
153
240
191
300
760,000 pixels type Figure 5 Figure 6 Figure 7 Figure 8
38
57 6.7
11.6
7.5
13
Field of vision
56
215
11.6
13
Field of vision
220
47.3 53
Field of vision
32
25.9 29
380
Field of vision
47.3 53
970
214
240
268
300
317
FQ2 Inspection systems
Optical Chart for C-mount Camera [email protected]@/[email protected]@
High-resolution, Low-distortion Lenses 3Z4S-LE [email protected]@@@H
10000
t0
3Z4S-LE
SV-0614H SV-0814H
Meaning of Optical Chart
TheX axisof the optical chart shows the field of vision (mm) (See Note.), and the Y axis of the op-
tical chart shows the camera installation dis-
1000
t50
t40t30
t25 t20
t5 t15t10
t5
t10
t0 t0 t0
t0
t0 t0
SV-1214H
SV-1614H SV-2514H SV-3514H SV-5014H
tance (mm).
Note: The lengths of the fields of vision given in the optical charts are the lengths of the Y axis.
t50 t40
t25t20
t15t5 t0
t0
SV-7525H
t30 t15t10 t0 t50 t40 t30 t25 t20t5 t2
SV-10028H
Camera
t30
t25 t20t15
t10
t5t2
t1 t0.5
Extension tube
100
10
1
t15
t10
t5t2
10
t1
t0.5
100
1000
Examples
t0: Extension tube is not required. t5: A 5-mm
extension tube is required.
Extension tube t_ (mm)
Camera lens
Measurement object
Camera installation distance (mm)
Y axis of field of view (mm)
Field of view (mm)
Touch Finder
Type Appearance Order code
DC power supply FQ2-D30
AC/DC/battery FQ2-D31
External Lighting
TypeModel
FLV series Refer to FLV series catalog Q198
Accessories
Application Appearance NameOrder code
Cables
Type Appearance Cable lengthOrder code
For SensorMounting Bracket*1
FQ-XL
FQ Ethernet Cables
(connect Sensor to Touch Finder, Sensor to PC)
Robotic
2m FQ-WN002
5m FQ-WN005
10m FQ-WN010
Mounting Bracket FQ-XL2
cable
20m FQ-WN020
Mounting Base for C-mount type*2
FQ-XLC
I/O Cables 2m FQ-WD002
5m FQ-WD005
Polarizing Filter Attachment*1FQ-XF1
Robotic
cable
Sensor Data Unit (FQ2-S3/S4/CH only)
10m FQ-WD010
20m FQ-WD020
For Touch
Finder
Panel Mounting Adapter FQ-XPM
Type Appearance Output type Order code
Parallel Interface NPN FQ-SDU10
PNPFQ-SDU15
RS-232C InterfaceNPN FQ-SDU20
AC Adapter
(for AC/DC/battery model)*4
Battery
(for AC/DC/battery model)
[email protected]
FQ-BAT1
PNPFQ-SDU25
Cables for Sensor Data Unit
Type Appearance Cable lengthOrder code
Sensor Data Unit Cable2m FQ-WU002
5m FQ-WU005
Touch Pen*4 FQ-XT Strap FQ-XH
SD CARD (4 GB)HMC-SD491
Parallel Cable for FQ-SDU1*1
Robotic cable
10m FQ-WU010
20m FQ-WU020
2m FQ-VP1002
*1Included with Integrated Sensor.
*2
5m FQ-VP1005
10m FQ-VP1010
Parallel Cable for FQ-SDU2*1 2m FQ-VP2002
5m FQ-VP2005
10m FQ-VP2010
RS-232C Cable for FQ-SDU2*1 2m XW2Z-200S-V
5m XW2Z-500S-V
*[email protected]@, 2 cables are required for all I/O signals.
Included with Sensor with C-mount.
*4. AC Adapters for Touch Finder with DC/AC/Battery Power Supply.Select the model for the country in which the Touch Finder will be used.
Plug TypeVoltage Certified standardsOrder code
A 125V max. PSE FQ-AC1
UL/CSA FQ-AC2
250V max. CCC mark FQ-AC3
C 250V max. –FQ-AC4
BF 250V max. –FQ-AC5
C 250V max. –FQ-AC6
*4. Enclosed with Touch Finder.
318
FQ2 Inspection systems
Industrial Switching Hubs (Recommended)
AppearanceNumber of ports
Failure detection Current consumption
Order code
3None 0.22 A W4S1-03B
5None 0.22 A W4S1-05B Supported W4S1-05C
Lenses for C-mount Camera. Refer to optical chart on p. 318 for selection of a lens.
High-resolution, Low-distortion Lenses
Model3Z4S-LE SV-0614H
3Z4S-LE SV-0814H
3Z4S-LE SV-1214H
3Z4S-LE SV-1614H
3Z4S-LE SV-2514H
3Z4S-LE SV-3514H
3Z4S-LE SV-5014H
3Z4S-LE SV-7525H
3Z4S-LE
SV-10028H
Appearance
42 dia.
57.5
39 dia.
52.5
30 dia.
51.0
30 dia.
47.5
30 dia.
36.0
44 dia.
45.5
44 dia.
57.5
36 dia.
49.5
39 dia.
66.5
Focal length 6 mm8 mm12 mm16 mm25 mm35 mm50 mm75 mm100 mm
Brightness F1.4F1.4 F1.4 F1.4 F1.4 F1.4F1.4 F2.5F2.8
Filter size M40.5P0.5M35.5 P0.5M27P0.5M27 P0.5M27P0.5M35.5P0.5M40.5P0.5M34.0P0.5M37.5 P0.5
Extension Tubes
Model3Z4S-LE SV-EXR
ContentsSet of 7 tubes
(40 mm, 20 mm,10 mm, 5 mm, 2.0 mm,1.0 mm, and 0.5 mm) Maximum outer diameter: 30 mm dia.
Note:Do not use the 0.5-mm, 1.0-mm, and 2.0-mm Extension Tubes attached to each other.
Since these Extension Tubes are placed over the threaded section of the Lens or other
Extension Tube, the connection may loosen when more than one 0.5-mm, 1.0-mm or
2.0-mm Extension Tube are used together.
Note:Reinforcement is required to protect against vibration when Extension Tubes exceed- ing 30 mm are used.
Ratings and Performance
Sensor
Inspection Model FQ2-S1/S2/S3 Series
ItemSingle-function type Standard type High-resolution type
[email protected]@@@[email protected]@@@[email protected]@@@-08 [email protected]@@@-08M FQ2-S30-13FQ2-S30-13M PNP [email protected]@@@[email protected]@@@[email protected]@@@-08 [email protected]@@@-08M FQ2-S35-13FQ2-S35-13M
Field of view Refer to Ordering Information on p.19. (Tolerance (field of vision): 10% max.) Select a lens according to the field of vision
Installation distance
and installation distance.
Refer to optical chart on p. 318.
Main
Inspection itemsSearch, shape search II, sensitive search, area, color data, edge position, edge pitch, edge width, and labeling
functions
Number of simultaneous measurements
132
Position compensationSupported (360º Model position compensation,Edge position compensation)
Number of registered scenes
832
CalibrationSupported
Image input Image processing method
Real color MonochromeReal colorMonochrome
Image filterHigh dynamic range (HDR), image adjustment (Color Gray Filter, Weak smoothing, Strong smoothing, Dilate, Erosion, Median, Extract edges, Extract horizontal edges, Extract vertical edges, Enhance edges, Background suppression), polarizing filter (attachment), and white balance (Sensors with Color Cameras only)
Image elements 1/3-inch color CMOS 1/2-inch color CMOS1/2-inch Monochrome
CMOS
1/2-inch color CMOS 1/2-inchMonochrome
CMOS
Shutter Built-in lighting ON: 1/250 to 1/50,000
Built-in lighting OFF: 1/1 to 1/50,000
Built-in lighting ON: 1/250 to 1/60,000
Built-in lighting OFF: 1/1 to 1/60,000
1/1 to 1/60,000
Processing resolution752  480 928  828 1,280  1,024
Partial input functionSupported horizontally only. Supported horizontally and vertically
Lens mounts– C-mount
LightingLighting methodPulse–
Lighting colorWhite –
Data loggingMeasurement data In Sensor: 1,000 items (If a Touch Finder is used, results can be saved up to the capacity of an SD card.)
Images In Sensor: 20 images (If a Touch Finder is used, images can be saved up to the capacity of an SD card.)
Auxiliary function Math (arithmetic, calculation functions, trigonometric functions, and logic functions)
Measurement trigger External trigger (single or continuous)
Communications trigger (Ethernet TCP no-protocol, Ethernet UDP no-protocol, Ethernet FINS/TCP no-protocol, EtherNet/IP, PLC Link, or PROFINET)
319
FQ2 Inspection systems
ItemSingle-function type Standard type High-resolution type
[email protected]@@@[email protected]@@@[email protected]@@@-08 [email protected]@@@-08MFQ2-S30-13FQ2-S30-13M PNP [email protected]@@@[email protected]@@@[email protected]@@@-08 [email protected]@@@-08MFQ2-S35-13FQ2-S35-13M
I/O specifica- Input signals7 signals
tions
Single measurement input (TRIG) Control command input (IN0 to IN5)
Output signals 3 signals
Control output (BUSY)
Overall judgement output (OR) Error output (ERROR)
The assignments of the three output signals(OUT0 to OUT2) can be changed to the individual judgements of the inspection items, the image input ready output (READY), or the external lighting timing output (STGOUT).
Ethernet specifications100Base-TX/10Base-T
Communications Ethernet TCP no-protocol, Ethernet UDP no-protocol, Ethernet FINS/TCP no-protocol, EtherNet/IP, PLC Link, or PROFINET
I/O expansion––Possible by connecting FQ-SDU1_ Sensor Data Unit. 11 inputs and 24 outputs
RS-232C ––Possible by connecting FQ-SDU2_ Sensor Data Unit. 8 inputs and 7 outputs
Ratings Power supply voltage21.6 to 26.4VDC (including ripple)
Current consumption 2.4 A max.0.3 A max.
Environmen- Ambient temperature tal immunityrange
Operating: 0 to 50ºC Storage: –25 to 65ºC
(with no icing or condensation)
Operating: 0 to 40ºC Storage: –25 to 65ºC
(with no icing or condensation)
Ambient humidity range
Operating and storage: 35% to 85% (with no condensation)
Ambient atmosphere No corrosive gas
Vibration resistance
(destruction)
Shock resistance
(destruction)
10 to 150 Hz, single amplitude: 0.35 mm, X/Y/Z directions
8 min each, 10 times
150 m/s2 3 times each in 6 direction (up, down, right, left, forward, and backward)
Degree of protectionIEC 60529 IP67 (Except when Polarizing Filter Attachment is mounted or connector cap is removed.)
MaterialsSensor: PBT, PC, SUS MountingBracket: PBT
Polarizing Filter Attachment: PBT, PC
Ethernet connector: Oil-resistance vinyl compound
I/O connector: Lead-free heat-resistant PVC
Weight Narrow View/Standard View:Approx.160 g
Wide View: Approx.150g
Accessories included with sensor Mounting Bracket (FQ-XL) (1)
Polarizing Filter Attachment(FQ-XF1) (1) Instruction Manual, Quick Startup Guide
Member Registration Sheet, Warning Label
LED classClass 2(Applicable standards: IEC 60825-1:1993 +A1:1997 +A2:2001, EN 60825-1:1994 +A1:2002 +A2:2001, and JIS C 6802:2005)
Applicable standardsEN standard EN 61326 and EC Directive No.2004/ EN 61326-1:2006 and IEC 61010-1
104/EC
Inspection/ID Model FQ2-S4 Series
ItemInspection/ID Model
IEC 60529 IP40
Cover: Zinc-plated steel, Thickness: 0.6 mm
Case: Aluminum diecast alloy (ADC-12) Mounting base: Polycarbonate ABS
Approx. 160 g without base, Approx. 185 g with base
Mounting Base (FQ-XLC) (1) Mounting Screw (M3  8mm) (4) Instruction Manual, Quick Startup Guide Member Registration Sheet

[email protected]@@@[email protected]@@@-M [email protected]@@@-08 [email protected]@@@[email protected]@@@-13 [email protected]@@@-13M PNP [email protected]@@@[email protected]@@@-M [email protected]@@@-08 [email protected]@@@[email protected]@@@-13 [email protected]@@@-13M
Field of view Refer to Ordering Information on p.19. (Tolerance (field of vision): 10% max.) Select a lens according to the field of vision
Installation distance
and installation distance.
Refer to optical chart on p. 318.
Main functions
Inspection itemsSearch, shape search II, sensitive search, area, color data, edge position, edge pitch, edge width, labeling, OCR*1, Bar code*2, 2D-code*2, 2D-code
(DMP)*3, and Model dictionary
Number of 32 simultaneous measurements
Position compensationSupported (360º Model position compensation, Edge position compensation)
Number of registered 32
scenes
CalibrationSupported
Retry functionNormal retry, Exposure retry, Scene retry, Trigger retry
Image input Image processing method
Real colorMonochromeReal colorMonochromeReal color
Monochrome
Image filterHigh dynamic range (HDR), image adjustment (Color Gray Filter, Weak smoothing, Strong smoothing, Dilate, Erosion, Median, Extract edges, Extract hor- izontal edges, Extract vertical edges, Enhance edges, Background suppression), polarizing filter (attachment), and white balance (Sensors with Color Cameras only)
Image elements 1/3-inch color CMOS1/3-inch Monochrome
CMOS
Shutter Built-in lighting ON: 1/250 to 1/50,000
Built-in lighting OFF: 1/1 to 1/50,000
1/2-inch color CMOS1/2-inch Monochrome
CMOS
Built-in lighting ON: 1/250to 1/60,000
Built-in lighting OFF: 1/1 to 1/60,000
1/2-inch color CMOS1/2-inch Monochrome
CMOS
1/1 to 1/60,000
Processing resolution752  480 928  828 1,280  1,024
Partial input functionSupported horizontally only. Supported horizontally and vertically
Lens mounts– C-mount
LightingLighting methodPulse–
Lighting colorWhite –
320
FQ2 Inspection systems
ItemInspection/ID Model
[email protected]@@@[email protected]@@@-M [email protected]@@@-08 [email protected]@@@[email protected]@@@-13 [email protected]@@@-13M PNP [email protected]@@@[email protected]@@@-M [email protected]@@@-08 [email protected]@@@[email protected]@@@-13 [email protected]@@@-13M
Data loggingMeasurement data In Sensor: 1,000 items (If a Touch Finder is used, results can be saved up to the capacity of an SD card.)
Images In Sensor: 20 images (If a Touch Finder is used, images can be saved up to the capacity of an SD card.)
Auxiliary function Math (arithmetic, calculation functions, trigonometric functions, and logic functions)
Measurement trigger External trigger (single or continuous)
Communications trigger (Ethernet TCP no-protocol, Ethernet UDP no-protocol, Ethernet FINS/TCP no-protocol, EtherNet/IP, PLC Link , or PROFINET)
I/O specifica- Input signals7 signals
tions
Single measurement input (TRIG) Control command input (IN0 to IN5)
Output signals 3 signals
Control output (BUSY)
Overall judgement output (OR) Error output (ERROR)
The assignments of the three output signals(OUT0 to OUT2) can be changed to the individual judgements of the inspection items, the image input
ready output (READY), or the external lighting timing output (STGOUT).
Ethernet specifications 100Base-TX/10Base-T
Communications Ethernet TCP no-protocol, Ethernet UDP no-protocol, Ethernet FINS/TCP no-protocol, EtherNet/IP, PLC Link, or PROFINET
I/O expansionPossible by connecting FQ-SDU1_ Sensor Data Unit. 11 inputs and 24 outputs
RS-232CPossible by connecting FQ-SDU2_ Sensor Data Unit. 8 inputs and 7 outputs
RatingsPower supply voltage
21.6 to 26.4VDC (including ripple)
Current consumption 2.4 A max.0.3 A max.
Environment Ambient temperature
Operating: 0 to 40ºC
al immunity
range
Ambient humidity range
Storage: –25 to 65ºC
(with no icing or condensation)
Operating and storage: 35% to 85% (with no condensation)
Ambient atmosphere No corrosive gas
Vibration resistance
(destruction)
Shock resistance
(destruction)
10 to 150 Hz, single amplitude: 0.35 mm,X/Y/Z directions
8 min each, 10 times
150 m/s2 3 times each in 6 direction (up, down, right, left, forward, and backward)
Degree of protectionIEC 60529 IP67 (Except when Polarizing Filter Attachmentis mounted or connector cap is removed.)
MaterialsSensor: PBT, PC, SUS MountingBracket: PBT
Polarizing Filter Attachment: PBT, PC
Ethernet connector: Oil-resistance vinyl compound
I/O connector: Lead-free heat-resistant PVC
Weight Narrow View/Standard View:Approx.160 g
Wide View:Approx.150 g
Accessories included with sensor Mounting Bracket (FQ-XL)(1)
Polarizing Filter Attachment (FQ-XF1) (1) Instruction Manual, Quick Startup Guide
Member Registration Sheet, Warning Label
LED classClass 2(Applicable standards: IEC 60825-1:1993 +A1:1997 +A2:2001, EN 60825-1:1994 +A1:2002 +A2:2001, and JIS C 6802:2005)
Applicable standardsEN 61326-1:2006 and IEC 61010-1
*1The types of characters to be read are the same as those of FQ2-CH Optical Character Recognition Sensor.
*2The types of codes to be read are the same as those of FQ-CR1 Multi Code Reader.
*3The types of codes to be read are the same as those of FQ-CR2 2D CodeReader.
IEC 60529 IP40
Cover: Zinc-plated steel, Thickness: 0.6 mm
Case: Aluminum diecast alloy (ADC-12) Mounting base: Polycarbonate ABS
Approx. 160 g without base, Approx. 185 g with base
Mounting Base (FQ-XLC) (1) Mounting Screw (M3  8mm)(4) Instruction Manual, Quick Startup Guide Member Registration Sheet

321
FQ2 Inspection systems
ID ModelFQ2-CH, FQ-CR1/CR2 Series
ItemOptical Character Recognition SensorMulti Code Reader 2D Code Reader
[email protected]@@@[email protected]@@@[email protected]@@@-M PNP [email protected]@@@[email protected]@@@[email protected]@@@-M
Field of view Refer to Ordering Information on page 316. (Tolerance (field of vision): 10% max.)
Installation distance
Main
Inspection itemsOCR
2D Code (DataMatrix(EC200), QR Code, MicroQR 2D Code
functions
Alphabet A to Z
Number 0 to 9
Symbol ' - .:/ Model dictionary
Code, PDF417, MicroPDF417, GS1-Data Matrix)
Bar Code (JAN/EAN/UPC, Code39, Codabar (NW-
7), ITF (Interleaved 2 of 5), Code 93, Code128/ GS1-128, GS1 DataBar* (Truncated, Stacked, Om-
nidirectional, Stacked Omnidirectional, Limited, Expanded, Expanded Stacked), Pharmacode, GS1-128 Composite Code (CC-A, CC-B, CC-C)
(Data Matrix(EC200),QR Code)
Image filterWeak smoothing, Strong smoothing, Dilate, Erosion, Median, Extract edges, Extract horizontal edges, Extract vertical edges, Enhance edges, Background suppression
None Filter function (Smooth, Dilate, Erosion, Median), Code Error CorrectionPosition Display
Verification functionSupportedSupportedNone
Retry functionNormal retry, Exposure retry, Scene retry, Trigger retry
Number of 32 simultaneous measurements
Position compensationSupported (360º Model position compensation, Edge position compensation)
None
Image input
Number of registered scenes
Image processing method
32
Monochrome
Image filterHigh dynamic range (HDR) and polarizing filter (attachment)
Image elements 1/3-inch Monochrome CMOS
Shutter Built-in lighting ON: 1/250 to 1/50,000
Built-in lighting OFF: 1/1 to 1/50,000
Processing resolution752  480
Partial input functionSupported horizontally only.
LightingLighting methodPulse
Lighting colorWhite
1/250 to 1/30,000 1/250 to 1/32,258
Data loggingMeasurement data In Sensor: 1,000 items (If a Touch Finder is used, results can be saved up to the capacity of an SD card.)
Images In Sensor: 20 images (If a Touch Finder is used, images can be saved up to the capacity of an SD card.)
Auxiliary function Math (arithmetic, calculation functions, trigonometric functions, and logic functions)
Measurement trigger External trigger (single or continuous) Communications trigger (Ethernet TCP no-proto- col, Ethernet UDP no-protocol, Ethernet FINS/TCP no-protocol, EtherNet/IP, PLC Link, or PROFINET)
I/O specifica- Input signals7 signals
External trigger (single or continuous)
tions
Single measurement input (TRIG) Control command input (IN0 to IN5)
Output signals 3 signals
Control output (BUSY)
Overall judgement output (OR) Error output (ERROR)
The assignments of the three output signals
(OUT0 to OUT2) can be changed to the individual judgements of the inspection items, the image in- put ready output (READY), or the external lighting timing output (STGOUT).
Ethernet specifications100Base-TX/10Base-T
Communications Ethernet TCP no-protocol, Ethernet UDP no-pro- tocol, Ethernet FINS/TCP no-protocol, EtherNet/IP, PLC Link, or PROFINET
I/O expansionPossible by connecting FQ-SDU1_ Sensor Data
Unit. 11 inputs and 24 outputs
RS-232C Possible by connecting FQ-SDU2_ Sensor Data
Unit. 8 inputs and 7 outputs
3 signals
Control output (BUSY)
Overall judgement output (OR) Error output (ERROR)
Note: The three output signals can be allocated for the judgements of individual inspection items.
Ethernet TCP no-protocol


Ratings Power supply voltage21.6 to 26.4VDC (including ripple)
Current consumption 2.4 A max.
Environment Ambient temperature
Operating: 0 to 40ºC, Storage: –25 to 65ºC
Operating: 0 to 50ºC, Storage: –25 to 65ºC
al immunity
range
(with no icing or condensation)
(with no icing or condensation)
Ambient humidity range
Operating and storage: 35% to 85% (with no condensation)
Ambient atmosphere No corrosive gas
Vibration resistance
(destruction)
Shock resistance
(destruction)
10 to 150 Hz, single amplitude: 0.35 mm, X/Y/Z directions
8 min each, 10 times
150 m/s2 3 times each in 6 direction (up, down, right, left, forward, and backward)
Degree of protectionIEC 60529 IP67 (Except when Polarizing Filter Attachment is mounted or connector cap is removed.)
322
FQ2 Inspection systems
ItemOptical Character Recognition Sensor Multi Code Reader 2D Code Reader
[email protected]@@@[email protected]@@@[email protected]@@@-M PNP [email protected]@@@[email protected]@@@[email protected]@@@-M
MaterialsSensor: PBT, PC, SUS, Mounting Bracket: PBT, Polarizing Filter Attachment: PBT, PC
Ethernet connector: Oil-resistance vinyl compound, I/O connector: Lead-free heat-resistant PVC
Weight Narrow View/Standard View: Approx.160g Wide View: Approx. 150 g
Accessories included with sensor Mounting Bracket (FQ-XL)(1), Polarizing Filter Attachment (FQ-XF1) (1), Instruction Manual, Quick Startup Guide, Member Registration Sheet, Warning
Label
LED classClass 2(Applicable standards: IEC 60825-1:1993 +A1:1997 +A2:2001,EN 60825-1:1994+A1:2002 +A2:2001, and JIS C 6802:2005)
Applicable standardsEN 61326-1:2006 and IEC61010-1
Touch Finder
ItemTypeModel with DC power supply Model with AC/DC/battery power supply
ModelFQ2-D30FQ2-D31
Number of connectable SensorNumber of sensors that can be recognized (switched): 32 max. number or sensor that can displayed on monitor: 8 max.
Main functionsTypes of measurement displaysLast result display, Last NG display,trend monitor, histograms
Types of display images Through, frozen, zoom-in, and zoom-out images
Data loggingMeasurement results, measured images
Menu languageEnglish, German, French, Italian, Spanish, Traditional Chinese, Simplified Chinese, Korean, Japanese
IndicationsLCDDisplaydevice 3.5-inch TFT color LCD
Pixels320  240
Display colors16.7 million
Backlight Life expectancy*1
50,000 hours at 25ºC
Brightness adjustment Provided
Screen saverProvided
Operation interface Touch screen MethodResistance film
Life expectancy*2
1,000,000 touch operations
External interfaceEthernet 100BASE-TX/10BASE-T
SD card SDHC-compliant, Class 4 or higher recommended
RatingsPower supply voltageDC power connection: 21.6 to 26.4VDC (including ripple) DC power connection: 21.6 to 26.4VDC (including ripple)
AC adapter (manufacturedby Sino-American Japan Co., Ltd)
connection: 100 to 240VAC, 50/60Hz
Battery connection: FQ-BAT1 Battery (1cell, 3.7 V)
Continuous operation on Battery*3
– 1.5 h
Power consumption DC power connection: 0.2 A max. DC power connection: 0.2 A max.
Charging battery:0.4 A max.
Environmental immunity
Ambient temperature rangeOperating: 0 to 50ºC Storage: –25 to 65ºC
(with no icing or condensation)
Ambient humidity rangeOperating and storage: 35% to 85% (with no condensation)
Ambient atmosphereNo corrosive gas
Operating: 0 to 50ºC when mounted to DIN Track or panel
Operation on Battery: 0 to 40ºC: –25 to 65ºC (with no icing or condensation)
Vibration resistance (destruction) 10 to 150 Hz, single amplitude: 0.35 mm, X/Y/Z directions 8 min each, 10 times Shock resistance (destruction) 150 m/s2 3 times each in 6 direction (up, down, right, left, forward, and backward) Degree of protectionIEC 60529 IP20 (when SD card cover, connector cap, or harness is attached)
Weight Approx. 270 g (without Battery and hand strap attached)
MaterialsCase: ABS
Accessories included with Touch FinderTouch Pen (FQ-XT), Instruction Manual
*1This is a guideline for the time required for the brightness to diminish to half the initial brightness at room temperature and humidity. The life of the backlight is greatly affected by the ambient temperature and humidity and will be shorter at lower or higher temperatures.
*2This value is only a guideline. No guarantee is implied. The value will be affected by operating conditions.
*3This value is only a guideline. No guarantee is implied. The value will be affected by the operating environment and operating conditions.
323
FQ2 Inspection systems
Sensor Data Units (FQ2-S3/S4/CH only)
ItemParallel InterfaceRS-232C Interface
Model NPN FQ-SDU10 FQ-SDU20
PNP FQ-SDU15 FQ-SDU25
I/O specificationsParallel I/OConnector 116 outputs (D0 to D15)6 inputs (IN0 to IN5)
Connector 211 inputs (TRIG, RESET, IN0 to IN7, and DSA)
8 outputs (GATE, ACK, RUN, BUSY, OR, ERROR, STGOUT, and
SHTOUT)
2 inputs (TRIG and RESET)
7 outputs (ACK, RUN, BUSY, OR, ERROR, STGOUT, and
SHTOUT)
RS-232C – 1 channel, 115,200 bps max.
Sensor interface FQ2-S3 connected with [email protected]@@: OMRON interface
*Number of connected Sensors: 1
RatingsPower supply voltage21.6 to 26.4VDC (including ripple)
Insulation resistanceBetween all DC external terminals and case: 0.5 M min (at 250 VDC)
Current consumption 2.5 A max.: [email protected]@@@@@[email protected]@@ and [email protected]@
0.4 A max.: [email protected]@@@and [email protected]@
0.1 A max.: [email protected]@ only
Environmental immunity
Ambient temperature rangeOperating: 0 to 50ºC, Storage: –20 to 65ºC (with no icing or condensation)
Ambient humidity rangeOperating and storage: 35% to 85% (with no condensation)
Ambient atmosphere No corrosive gas
Vibration resistance (destruction) 10 to 150 Hz, single amplitude: 0.35 mm,X/Y/Z directions, 8 min each, 10 times Shock resistance (destruction) 150 m/s² 3 times each in 6 directions (up, down, right, left, forward, and backward) Degree of protectionIEC 60529 IP20
MaterialsCase: PC + ABS, PC Weight Approx. 150 g Accessories included with Sensor Data UnitInstruction Manual
Battery
ItemModel FQ-BAT1
Battery typeSecondary lithium ion battery
Nominal capacity 1,800 mAh
Rated voltage 3.7 V
Ambient temperature rangeOperating: 0 to 40ºC
Storage: –25 to 65ºC (with no icing or condensation)
Ambient humidity rangeOperating and storage: 35% to 85% (with no condensation)
Charging methodCharged in Touch Finder (FQ2-D31). AC adapter ([email protected]) is required.
Charging time*1 2 h
Usage time*1 1.5 h
Battery backup life*2
300 charging cycles
Weight 50 g max.
*1This value is only a guideline. No guarantee is implied. The value will be affected by operating conditions
*2This is a guideline for the time required for the capacity of the Battery to be reduced to 60% of the initial capacity. No guarantee is implied. The value will be affected by the operating environment and operating conditions.
System Requirements for PC tool for FQ
The following Personal Computer system is required to use the software.
OSMicrosoft Windows XP Home Edition/ProfessionalSP2 or higher (32-bit version) Microsoft Windows 7 Home Premium or higher (32-bit/64-bit version)
CPU Core 2 Duo 1.06 GHz or the equivalent or higher
RAM1GB min.
HDD500 MB min. available space*1
Monitor1,024  768 dots min.
*1Available space is also required separately for data logging.
Windows is registered trademarksof Microsoft Corporation in the USA and other countries.
Other company names and product names in this document are the trademarks or registered trademarks of their respective companies.
324

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Últimas Opiniones de Nuestros Clientes

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.