ZX-LT001 145951 OMRON Advanced Sensors, Laser Barrier 2000mm 4 microns Make 1mm View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

ZX-LT001 145951 OMRON Advanced Sensors, Laser Barrier 2000mm 4 microns Make 1mm

ZX-LT001

145951

OMRON

Available

Ship on today

Advanced Sensors, Laser Barrier 2000mm 4 microns Make 1mm

More details


Monitoring Products Measurement

ZX

* Brand new product in its original packaging covered by the warranties and certifications provided by OMRON

*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



ZX-L Laser displacement sensor
Smart, fast and accurate laser measurement sensor
Smart ZX-L-N offers plug & measure technology for applications where high resolution and fast response time is required. A wide range of interchangeable sensor heads
provides greater flexibility in solving most demanding applications.
• Small and light sensor heads for easy integration
• High speed response time of 150 μs
• Easy sensor head replacement
• Scalability through a modular platform concept
• Multipoint measurement with up to 5 sensors
• Wide range of sensor heads offering laser beam width from 1 mm to 30 mm
Ordering information
Sensors
Sensor head (reflection type)
Optical method Beam shape Sensing distance Resolution *1
Size in mm (H ×W × D) Order code
Diffuse-reflective Spot beam 40±10 mm 2 μm 39 × 33 × 17 ZX-LD40
100±40 mm 16 μm ZX-LD100
300±200 mm 300 μm ZX-LD300
Line beam 40±10 mm 2 μm ZX-LD40L
100±40 mm 16 μm ZX-LD100L
300±200 mm 300 μm ZX-LD300L Regular reflection type Spot beam 30±2 mm 0.25 μm 45 × 55 × 25 ZX-LD30V
Line beam ZX-LD30VL
*1 At average count of 4,096 times
Sensor head (through-beam)
Optical method Measurement width Sensing distance Resolution *1
Size in mm (H ×W × D) Order code
Transmitter Receiver
Through-beam 1 mm dia. 0 to 2,000 mm 4 μm 15 × 15 × 34 15 × 15 × 19 ZX-LT001
5 mm 0 to 500 mm ZX-LT005
10 mm 20 × 20 × 42 20 × 20 × 25 ZX-LT010
30 mm 12 μm 64.25 × 70 × 22.6 64.25 × 54 × 22.6 ZX-LT030
*1 At average count of 64 times
Amplifier units
Power supply Output specifications Order code
DC NPN output ZX-LDA11-N PNP output ZX-LDA41-N
Note: Compatible with sensor head connection.
Accessories (order separately)
Calculating unit
Order code
SmartMonitor sensor setup tool for Personal Computer connection
Name Order code
Calculating unit ZX-CAL2
ZX-series communications interface unit ZX-SF11
Side-view attachments
ZX-series communications interface unit
+ Setup Software (CD-ROM)
ZX-SFW11EV3*1,*2
Applicable sensor head Order code
ZX-LT1001/LT005 ZX-XF12
ZX-LT010 ZX-XF22
ZX-series sensor setup and logging software (CD-ROM) ZX-SW11EV3*1
*1 When using the ZX-TDA11/41 with the SmartMonitor, either the ZX-SFW11EV3 or the
ZX-SW11EV3 SmartMonitor must be used. Earlier versions cannot be used.
*2 The ZX-SFW11EV3 SmartMonitor can be used only to set functions and monitor wave- forms.
Cables with connectors on both ends (for extension)*1
Cable length Order code
1 m ZX-XC1A
4 m ZX-XC4A
8 m ZX-XC8A
9 m*2. ZX-XC9A
*1. Robot cable models are also available. The model numbers are ZX-XC_R.
*2. For use only with reflective sensors.
381
ZX-L Laser displacement sensor
Specifications
Sensor head (reflection type)
Item ZX-LD40 ZX-LD100 ZX-LD300 ZX-LD30V ZX-LD40L ZX-LD100L ZX-LD300L ZX-LD30VL
Optical method Diffuse reflection Regular reflection
Diffuse reflection Regular reflection
Light source (wave length) Visible-light semiconductor laser (wavelength 650 nm, 1 mW or less, Class 2)
Measurement center distance 40 mm 100 mm 300 mm 30 mm 40 mm 100 mm 300 mm 30 mm Measurement range ±10 mm ±40 mm ±200 mm ±2 mm ±10 mm ±40 mm ±200 mm ±2 mm Beam shape Spot Line
Beam diameter*1
Resolution*2
50 μm dia. 100 μm dia. 300 μm dia. 75 μm dia. 75 μmx2mm 150 μmx2 mm 450 μmx2 mm 100 μmx1.8 mm
2 μm 16 μm 300 μm 0.25 μm 2 μm 16 μm 300 μm 0.25 μm
Linearity*3
±0.2% F.S.
±0.2% F.S.
±2% F.S.
±0.2% F.S.
±0.2% F.S.
±0.2% F.S.
±2% F.S.
±0.2% F.S.
(entire range)
(80 to 121 mm)
(200 to 401 mm) (entire range)
(32 to 49 mm)
(80 to 121 mm)
(200 to 401 mm) (entire range)
Temperature characteristic*4
±0.03% FS/°C (except for ZX-LD300 and ZX-LD300L, which are ±0.1% FS/°C.)
Ambient illumination Incandescent lamp: 3,000 lx max. (on light receiving side)
Ambient temperature Operating: 0 to 50°C, storage: –15 to 60°C (with no icing or condensation)
Ambient humidity Operating and storage: 35% to 85% (with no condensation)
Insulation resistance 20 M min. at 500 VDC
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min
Vibration resistance
(destruction)
Shock resistance
(destruction)
10 to 150 Hz, 0.7-mm double amplitude 80 min each in X, Y, and Z directions
300 m/s2 3 times each in six directions (up/down, left/right, forward/backward)
Protective structure IEC 60529 IP50 IEC standard IP40 IEC 60529 IP50 IEC standard IP40
Connection method Connector relay (standard cable length: 500 mm)
Weight (packed state) Approx. 150 g Approx. 250 g Approx. 150 g Approx. 250 g
Materials Case: PBT (polybutylene terephthalate), Cover: Aluminum, lens: Glass
Accessories Instruction sheet, Laser warning label (English)
Case and cover: Aluminum, lens: Glass
Case: PBT (polybutylene terephthalate), Cover: Aluminum, lens: Glass
Case and cover: Aluminum, lens: Glass
*1 Beam diameter: This is the value of the measurement center distance (actual value), and is defined at 1/e2 (13.5%) of the central light intensity. If there is stray light outside, the defined area and the area around the object has a higher reflectance than the object.
*2 Resolution: Indicates the amount of fluctuation (±3 ) in the linear output when connected to the ZX-LDA. (The measured value when the average count of the ZX-LDA is set to 4,096 and our
standard object (white ceramic) is used for the central distance.) This indicates the repeatability precision when the work is in a static state, and does indicate the distance precision. The resolution performance may not be satisfactory in a strong electromagnetic field.
*3 Linearity: This indicates the error with respect to the ideal straight line of the displacement output when measuring our standard object.
*4 Temperature characteristic: The temperature characteristic is measured at the measurement point with the sensor and reference object (Omron’s standard reference object) secured with an aluminum jig.
Note: Highly reflective objects can result in incorrect detection by causing out-of-range measurements.
Sensor head (through-beam)
Item ZX-LT001 ZX-LT005 ZX-LT010 ZX-LT030
Optical method Through-beam
Light source (wave length) Visible-light semiconductor laser (wavelength 650 nm, 1 mW or less, Class 1)
Maximum output 0.2 mW max. 0.35 mW max. 0.2 mW max.
Measurement width 1 mm dia. 1 to 2.5 mm dia. 5 mm 10 mm 30 mm
Sensing distance 0 to 500 mm 500 to 2,000 mm 0 to 500 mm
Min. sensing object 8 mm dia. opaque object
8 to 50 μm opaque object
opaque: 0.05 mm dia. opaque: 0.1 mm dia. opaque: 0.3 mm dia.
Resolution*1
4 μm*2
– 4 μm*3
12 μm*4
Temperature characteristic 0.2% FS/C 0.3% FS/C
Ambient illumination Incandescent lamp: 10,000 lx max. (on light-receiving side)
Ambient temperature Operating: 0 to 50C, storage: –25 to 70C (with no icing or condensation)
Ambient humidity Operating: 35% to 85% (with no condensation)
Protective structure IEC 60529 IP40 IP 40
Connection method Connector relay (standard cable length: 500 mm)
Weight (packed state) Approx. 220 g Approx. 450 g
Cable length Extendable up to 10 m with special extension cable.
Materials Case Polyetherimide Zinc die-cast
Cover Polycarbonate
Front filter Glass
Tightening torque 0.3 Nm max.
Accessories Instruction sheet, sensor head-amplifier connection cable
Optical axis adjustment seal Mounting Bracket
*1 The amount of fluctuation (±3 ) of the linear output when connected to an amplifier unit, converted to a detection span.
*2 When the average count is 64. 5 μm when the count is 32. The value when the smallest detection object shades the vicinity of the center of the 1 mm dia. detection span.
*3 When the average count is 64. 5 μm when the count is 32.
*4 For an average count of 64. The value is 15 μm for an average count of 32.
382
ZX-L Laser displacement sensor
Amplifier units
Item ZX-LDA11-N ZX-LDA41-N Measurement period 150 s
Possible average count settings*1
1, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1,024, 2,048, or 4,096
Temperature characteristic When connected to a reflective sensor head: 0.01% FS/C, when connected to a through-beam sensor head: 0.1% FS/C
Linear output*2
4 to 20 mA/FS, max. load resistance: 3004 V ( 5 V, 1 to 5 V *3), output impedance: 100 
Judgement outputs
(3 outputs: HIGH/PASS/LOW)*1
Laser OFF input, zero reset input, timing input, reset input
NPN open-collector outputs, 30 VDC, 50 mA max. Residual voltage: 1.2 V max.
ON: Short-circuited with 0-V terminal or 1.5 V or less
OFF: Open (leakage current: 0.1 mA max.)
PNP open-collector outputs, 30 VDC, 50 mA max. Residual voltage: 2 V max.
ON: Supply voltage short-circuited or supply voltage within 1.5 V OFF: Open (leakage current: 0.1 mA max.)
Functions Measurement value display, present value/set value/light level/resolution display, scaling, display reverse, display OFF mode, ECO mode, number of display digit changes, sample hold, peak hold, bottom hold, peak-to-peak hold, self-peak hold, self-bottom hold, average hold, delay hold, inten- sity mode, zero reset, initial reset, ON-delay timer, OFF-delay timer, one-shot timer, deviation, previous value comparison, sensitivity adjustment, keep/clamp switch, direct threshold value setting, position teaching, 2-point teaching, automatic teaching, hysteresis width setting, timing inputs,
reset input, monitor focus, linear output compensation, (A-B) calculations*4, (A+B) calculations*4, mutual interference*4, laser deterioration detec- tion, zero reset memory, zero reset display, key lock
Indications Operation indicators: High (orange), pass (green), low (yellow), 7-segment main display (red), 7-segment subdisplay (yellow), laser ON (green), zero reset (green), enable (green)
Power supply voltage 12 to 24 VDC10%, Ripple (p-p): 10% max.
Current consumption 140 mA max. with power supply voltage of 24 VDC (with sensor connected) Ambient temperature Operating: 0to 50C, storage: –15 to 60°C (with no icing or condensation) Ambient humidity Operating and storage: 35% to 85% (with no condensation)
Insulation resistance 20 M min. at 500 VDC
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min
Vibration resistance
(destruction)
Shock resistance
(destruction)
10 to 150 Hz, 0.7-mm double amplitude 80 min each in X, Y, and Z directions
300 m/s2 3 times each in six directions (up/down, left/right, forward/backward)
Connection method Prewired (standard cable length: 2 m)
Weight (packed state) Approx. 350 g
Materials Case: PBT (polybutylene terephthalate), cover: Polycarbonate
Accessories Instruction sheet
*1 The response speed of the linear output is calculated as the measurement period x (average count setting + 1) (with fixed sensitivity).
The response speed of the judgement outputs is calculated as the measurement period x (average count setting + 1) (with fixed sensitivity).
*2 The output can be switched between a current output and voltage output using a switch on the bottom of the amplifier unit.
*3 Setting is possible via the monitor focus function.
*4 A calculating unit (ZX-CAL2) is required.
Calculating unit
Item ZX-CAL2
Applicable amplifier units ZX-LDA11-N/41-N/ZX-EDA11/41/ZX-TDA11/41
Current consumption 12 mA max. (supplied from the smart sensor amplifier unit)
Ambient temperature Operating: 0 to 50C, storage: –15 to 60°C (with no icing or condensation)
Ambient humidity Operating and storage: 35% to 85% (with no condensation)
Connection method Connector
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min
Insulation resistance 100 M (at 500 VDC)
Vibration resistance (destructive) 10 to 150 Hz, 0.7-mm double amplitude 80 min each in X, Y, and Z directions Shock resistance (destructive) 300 m/s2 3 times each in six directions (up/down, left/right, forward/backward) Materials Display: Acrylic, case: ABS resin
Weight (packed state) Approx. 50 g
ZX-series Communications Interface Unit
Item ZX-SF11
Current consumption 60 mA max. (supplied by the amplifier unit)
Applicable amplifier units ZX series
Applicable amplifier unit versions ZX-LDA_ 1-N Ver. 1.000 or higher
ZX-EDA_ 1 Ver. 1.100 or higher
ZX-TDA_ 1 Ver. 1.000 or higher
Max. No. of amplifier units 5
Communications functions
Communications port
Communications protocol
RS-232C port (9-pin D-Sub connector)
CompoWay/F*1
Baud rate 38,400 bps
Data configuration Data bits: 8, parity: none, start bits: 1, stop bits: 1, flow control: none
Indicators Power supply: green, sensor communications: green, sensor communications error: red, external terminal communications: green, external terminal communications error: red
Protective circuits Reverse polarity protection
Ambient temperature Operating: 0 to 50C, storage: –15 to 60°C (with no icing or condensation)
Ambient humidity Operating and storage: 35% to 85% (with no condensation)
Insulation resistance 20 M min. (at 500 VDC)
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min, Leakage current: 10 mA max. Materials Case: PBT (polybutylene terephthalate), cover: Polycarbonate Accessories Instruction sheet, 2 clamps
*1 Contact your Omron representative for CompoWay/F communications specifications.
383

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.