E3X-HD8 356810 OMRON Photoelectric sensors, cc Display Connector M / S PNP Teach GIGA RAY II Smart Led View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

E3X-HD8 356810 OMRON Photoelectric sensors, cc Display Connector M / S PNP Teach GIGA RAY II Smart Led

E3X-HD8

356810

OMRON

Available

Ship on today

Photoelectric sensors, cc Display Connector M / S PNP Teach GIGA RAY II Smart Led

More details


Fiber Optic Sensors Optical

E3X

* Brand new produt in its original packing covered by the warranties and certifications provided by OMRON

QuantityPrice
1+125,88 €
2+122,44 €
3+120,73 €
4+119,64 €
6+118,31 €
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



E3X-HD Fiber amplifier
Easy-teach digital fiber amplifier
The E3X-HD with 1-buttonSmart tune set-up provides fast and simple teaching. Dual digital display and advanced features make the E3X-HD ideal even for demanding
applications.
• Easy teachingby Smart tuning within a few seconds
• Dynamic Power Control (DPC) for highest operational stability for changing environmental conditions or challenging objects
• M8 connectormodels
•EtherCAT and CompoNet Communication units for high-speedfield bus connectivity
Ordering information
ItemOrder code
Transistor output modelsCommunication unit model*1
NPN outputPNP output
Pre-wired E3X-HD11 2ME3X-HD41 2M–
Fiber amplifier connectorE3X-HD6 E3X-HD8 E3X-HD0
M8 connector (4pin) E3X-HD14 E3X-HD44 –
*1For field bus connection please chose Communication unit E3X-ECT for EtherCATor E3X-CRT for CompoNet.
Fiber amplifier connectors
ShapeTypeComment Order code
Fiber amplifier connector2 m PVC cableE3X-CN11
30 cm PVC cable with M12 plug connector (4 pin) E3X-CN21-M1J 0.3M
30 cm PVC cable with M8 plug connector (4 pin) E3X-CN21-M3J-2 0.3M
Communication units
ShapeCommunications method Applicable Fiber Amplifier Units Order code
CompoNet E3X-HD0
E3X-MDA0
E3X-DA0-S
E3X-CRT
EtherCATE3X-ECT
252
E3X-HD Fiber amplifier
Specifications
TypeStandard models For Communications
Unit
Model E3X-HD11E3X-HD41E3X-HD6E3X-HD8E3X-HD14 E3X-HD44E3X-HD0
Connection method Pre-wired Wire-saving connector M8-4pin connector Communications unit connector
Control output NPN outputPNP outputNPN outputPNP output NPN outputPNP output – Light source (wavelength)Red, 4-elementLED (625nm)
Power supply voltage12 to 24 VDC±10%, ripple (p-p) 10% max.
Power consumptionNormal Mode: 720 mW max. (Current consumption:30 mA max. at 24 VDC, 60 mA max. at 12 VDC.)
Power Saving Eco Mode: 530 mW max. (Current consumption: 22 mA max. at 24 VDC, 44 mA max. at 12 VDC.)
Control output Load power supply voltage: 26.4VDC max., open-collector output (Varies with the model depending on–
output is PNP or NPN.)Load current:50 mA max. (residualvoltage: 2 V max.), OFF current: 0.5 mA max.
Super-high-speed Mode Operate or reset:50 μs (NPN models) or 55 μs (PNP models)
(SHS)
High-speed Mode (HS) Operate or reset: 250 μs
Standard Mode (STND) Operate or reset: 1 ms
Giga-power Mode
(GIGA)
Mutual interference prevention
Maximum connectable Units
Operate or reset: 1 ms
Possible for up to 10 units
16 units with E3X-CRT:
16 units
with E3X-ECT:
30 units
253
E3X-HD Fiber amplifier
Easy One-Button-Teaching/Smart Tuning
Easy Solution Fewer Setting Steps
Setting of Smart Tuning
Conventional Model E3X-HD
1
Step
Power adjustment
2
1
Step
Smart tuning
Power adjustment
With workpieceWithout workpiece
Step
Threshold setting
Threshold setting
Press only twice.
Optimum settings
Optimum settings
Incident level adjustment with workpiece
Incident level adjustment without workpiece
Easy Solution
Optimum settings for saturated and low incident level
Threshold setting
Set to intermediate value between the incident levels with and without a workpiece.
Settings are simultaneously completed.
Easy settingof optimumpowerand thresholdby pushingtunebuttontwice.
Smart power control
APC
Always ON
Long-term stability
(AUTO POWER CONTROL)
Automatically compensate light intensity
WithoutAPC
With APC
Time
Smart Power
Control
DPC
Incident level
Compen-Compen-Compen-
(DYNAMIC POWER CONTROL)
Automatically compensate incident level
Target value (displayed incident level)
Setting value
(threshold value)
sated.
sated.
sated.
Flashes when compensation is
no longer possible.
DPC
Time
Enhanced signal stability control for compensating power reductions caused by temperaturedrift, dust or aging of LED.
Field bus connectivity
E3X-CRT
E3X-ECT
Field bus communicationallows control by an external device to simplify setup and reduce wiring effort.
254

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoFibre optic amplifier, PNP, 24VDC, connector version - OMRON - E3X-HD8 - 356810English285 Kbytespdf1-mostradoFibre optic amplifier, PNP, 24VDC, connector version - OMRON - E3X-HD8 - 356810
pdf1-Fibre optic amplifier, PNP, 24VDC, connector version - OMRON - E3X-HD8 - 356810English13 Mbytespdf1-mostradoFibre optic amplifier, PNP, 24VDC, connector version - OMRON - E3X-HD8 - 356810
pdf2-Fibre optic amplifier, PNP, 24VDC, connector version - OMRON - E3X-HD8 - 356810English4 Mbytespdf1-mostradoFibre optic amplifier, PNP, 24VDC, connector version - OMRON - E3X-HD8 - 356810

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review