Product successfully added to your shopping cart
ZX-TDS10T-VL
197356
ZXTDS10TVL
OMRON
1
Available Ship on today
Advanced sensors > ZX
* Brand new product in its original packaging covered by the warranties and certifications provided by OMRON
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Note: The resolution refers to the minimum value that can be read when a ZX-TDA_1 amplifier unit is connected.
ZX-SW11EV31 |
*Robot cable models are also available. The model numbers are ZX-XC_R.
Measuring ordinary flat surfaces (standard | |||||
Mounting D5SN-TN1/-TF1 or commercially |
Note:Replacement possibleConversion adapter required
Possible average count settings3 | ||
Linear output4 | Current output: 4 to 20 mA/F.S., max. load resistance: 300 Ω Voltage output: ±4 V (±5 V, 1 to 5 V5), output impedance: 100 Ω | |
NPN open-collector outputs, 30 VDC, 30 mA max. | PNP open-collector outputs, 30 VDC, 30 mA max. | |
Zero reset input, timing input, reset input, judgement output hold input | ON: Supply voltage short-circuited or supply voltage of 1.5 V or less | |
| ||
Judgement indicators: High (orange), pass (green), low (yellow), 7-segment main digital display (red), 7-segment sub-digital | ||
140 mA max. (with sensor connected), for 24-VDC power supply voltage: 140 mA max. (with sensor connected) | ||
Operating and storage: 0 to 50°C (with no icing or condensation) | ||
Case: PBT (polybutylene terephthalate), cover: Polycarbonate |
Resolution7 | ||||
Linearity8 | ||||
Operating force9 | ||||
Operating: 0 to 50°C, storage:-15 to 60°C (with no icing or condensation) | ||||
Operating and storage: 35% to 85% (with no icing or condensation) | ||||
Temperature characteristic10 | ||||
Instruction manual, preamplifier mounting brackets (ZX-XBT1) |
1.When using the ZX-TDA11/41 with the SmartMonitor, either the ZX-SFW11EV3 or the
ZX-SW11EV3 SmartMonitor must be used. Earlier versions cannot be used.
3.The response speed of the linear output is calculated as the measurement period x (average count setting + 1).
The response speed of the judgement outputs is calculated as the measurement period x (average count setting + 1).
4.The output can be switched between a current output and voltage output using a switch on the bottom of the amplifier unit.
7.The resolution is given as the minimum value that can be read when a ZX-TDA_1 amplifier unit is connected. This value is taken 15 minutes after turning ON the power with the average number of operations set to 256.
9.These figures are representative values that apply for the measurement mid-point, and are for when the provided actuator is used, with the actuator moving downwards. If the actuator moves horizontally or upwards, the operating force will be reduced. Also, if an actuator other than the standard one is used, the operating force will vary with the weight of the actuator itself.
Title: | Size: | Type: |
---|---|---|
ZX-TDS10T-VL ZXTDS10TVL 197356 EN_ZX-TDS01T.pdf | 1 Mbytes | |
ZX-TDS10T-VL ZXTDS10TVL 197356 zx_t_series_brochure_en.pdf | 606 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.