730476 GENERAL ELECTRIC Switch-disconnector Dilos 4 500A 3P View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

730476 GENERAL ELECTRIC Switch-disconnector Dilos 4 500A 3P

730476

GENERAL ELECTRIC

Available

Ship on today

Switch-disconnector Dilos 4 500A 3P

More details


Residual Current Devices Rcd Ground Fault Circuit Interrupter Gfci Breaker Rccb

Industrial

DIFFERENTIAL PROTECTION

* Brand new produt in its original packing covered by the warranties and certifications provided by GENERAL ELECTRIC

QuantityPrice
1+179,79 €
2+175,84 €
3+174,66 €
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Dilos 4 - 400A up to 630A

Performance

  • Panel mounting
  • Safety-switch-disconnector (main disconnector)
  • Disconnect function
  • Visible contact indication - transparent cover
  • Quick make and quick break mechanism
  • Independent opening and closing
  • Positive contact indication (PCI)
  • Defeat mechanism rotary handle
  • Double knife contacts - high short-circuit resistance
  • Number of poles 3P - 4P
  • With changeover system
Standards

IEC 60947-1 and IEC 60947-3, DIN VDE 0660 Teil 107,BS EN 60947-3, CEI 17-11 (Fasc. 1039), EN 60947-3, NBN EN 60947-3, NF C 63-130, UL 508 Safety-switch-disconnector (red/yellow) according to DIN VDE 0113 Teil 1

SPECIFICATIONS

SeriesSwitch-disconnectors - DILOS
Conventional enclosed thermal current Ithe = Ith500 A
Number of poles3P
Type of disconnectorSwitch-disconnector
Contact position indicationVisible contact position indication
MountingPanel mounting
Type of Dilos/FulosDILOS 4
400/415V (AC23A/AC23B)500 A
500V (AC23A/AC23B)500 A
690V (AC23A/AC23B)400 A
400/415V (AC22A/AC22B)500 A
500V (AC22A/AC22B)500 A
690V (AC22A/AC22B)500 A
400/415V (AC21A/AC21B)500 A
500V (AC21A/AC21B)500 A
690V (AC21A/AC21B)500 A
Rated operational voltage Ue (V)690 V
Rated impulse withstand voltage (2000 m) Uimp8 kV
StandardsBSNBNEN60947-3;CEI17-11(Fasc.1039);DINVDE0660Teil1;IEC60947-1;IEC60947-3;K63B;NBNEN60947-3;NFC63130
ApprovalsKEMA
Conventional enclosed thermal current lthe500 A
Maximum torque on terminals (Nm)60 Nm
Rated insulation voltage Ui (V)1000 V
Durability (number of operational cycles) electrical700
Max Rated Operational Power 400/415V (AC23 (kW))270 kW/285 kW
Max Rated Operational Power 500V (AC23 (kW))370 kW
Max Rated Operational Power 690V (AC23 (kW))440 kW
Rated capacity power at 400V (kVAR)242 kVAr
Terminal capacity (Cu-rail mm x mm)Cu-rail 2x40x6 mm
Rated short circuit making cap Icm (kA peak) Ue = 400V60 kA
Rated short circuit making cap Icm (kA peak) Ue = 415V60 kA
Rated short circuit making cap Icm (kA peak) Ue = 500V60 kA
Rated short circuit making cap Icm (kA peak) Ue = 690V60 kA
Rated short time withstand current Icw (kA rms) 1 s20 kA
Rated short time withstand current Icw (kA rms) 0.25 s35 kA
Durability (number of operational cycles) mech. (min.)5000
Rated Cond S/C current Backup protection kA rms @ 400V100 kA
Rated Cond S/C current Backup protection kA rms @ 415V100 kA
Rated Cond S/C current Backup protection kA rms @ 500V100 kA
Rated Cond S/C current Backup protection kA rms @ 690V100 kA

DIMENSIONS

Weight9 kg

CLASSIFICATION

ETIM 5.0EC000216
ETIM 6.0EC000216

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review