Performance
Series | Switch-disconnectors - DILOS |
Conventional enclosed thermal current Ithe = Ith | 200 A |
Number of poles | 4P |
Type of disconnector | Switch-disconnector |
Contact position indication | Visible contact position indication |
Mounting | Panel mounting |
Type of Dilos/Fulos | DILOS 3 |
400/415V (AC23A/AC23B) | 200 A |
500V (AC23A/AC23B) | 200 A |
690V (AC23A/AC23B) | 200 A |
400/415V (AC22A/AC22B) | 200 A |
500V (AC22A/AC22B) | 200 A |
690V (AC22A/AC22B) | 200 A |
400/415V (AC21A/AC21B) | 200 A |
500V (AC21A/AC21B) | 200 A |
690V (AC21A/AC21B) | 200 A |
110V (DC23A 2P) | 200 A |
250V (DC23A 2P) | 160 A |
250V (DC23A 4P) | 200 A |
Rated operational voltage Ue (V) | 690 V |
Rated impulse withstand voltage (2000 m) Uimp | 8 kV |
Standards | BSNBNEN60947-3;CEI17-11(Fasc.1039);DINVDE0660Teil1;IEC60947-1;IEC60947-3;K63B;NBNEN60947-3;NFC63130 |
Approvals | KEMA |
Conventional enclosed thermal current lthe | 200 A |
Maximum torque on terminals (Nm) | 12 Nm |
Rated insulation voltage Ui (V) | 1000 V |
Durability (number of operational cycles) electrical | 1000 |
Max Rated Operational Power 400/415V (AC23 (kW)) | 88 kW/92 kW |
Max Rated Operational Power 500V (AC23 (kW)) | 175 kW |
Max Rated Operational Power 690V (AC23 (kW)) | 190 kW |
Rated capacity power at 400V (kVAR) | 97 kVAr |
Terminal capacity (Cu-rail mm x mm) | Cu-rail 30x6 mm |
Rated short circuit making cap Icm (kA peak) Ue = 400V | 30 kA |
Rated short circuit making cap Icm (kA peak) Ue = 415V | 30 kA |
Rated short circuit making cap Icm (kA peak) Ue = 500V | 30 kA |
Rated short circuit making cap Icm (kA peak) Ue = 690V | 30 kA |
Rated short time withstand current Icw (kA rms) 1 s | 9 kA |
Rated short time withstand current Icw (kA rms) 0.25 s | 15 kA |
Durability (number of operational cycles) mech. (min.) | 10000 |
Rated Cond S/C current Backup protection kA rms @ 400V | 100 kA |
Rated Cond S/C current Backup protection kA rms @ 415V | 100 kA |
Rated Cond S/C current Backup protection kA rms @ 500V | 100 kA |
Rated Cond S/C current Backup protection kA rms @ 690V | 100 kA |
Weight | 2.9 kg |
ETIM 5.0 | EC000216 |
ETIM 6.0 | EC000216 |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.