730494 GENERAL ELECTRIC Switch-disconnector Dilos 3 200A 3P+N View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

730494 GENERAL ELECTRIC Switch-disconnector Dilos 3 200A 3P+N

730494

GENERAL ELECTRIC

Available

Ship on today

Switch-disconnector Dilos 3 200A 3P+N

More details


Residual Current Devices Rcd Ground Fault Circuit Interrupter Gfci Breaker Rccb

Industrial

DIFFERENTIAL PROTECTION

* Brand new produt in its original packing covered by the warranties and certifications provided by GENERAL ELECTRIC

QuantityPrice
1+110,16 €
2+107,40 €
3+106,03 €
4+105,16 €
5+105,00 €
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Dilos 3 - 160A up to 315A

Performance

  • Panel mounting
  • Safety-switch-disconnector (main disconnector)
  • Disconnect function
  • Visible contact indication - transparent cover
  • Quick make and quick break mechanism
  • Independent opening and closing
  • Positive contact indication (PCI)
  • Defeat mechanism rotary handle
  • Double knife contacts - high short-circuit resistance
  • Number of poles 3P - 4P
  • With changeover system
Standards

IEC 60947-1 and IEC 60947-3, DIN VDE 0660 Teil 107,BS EN 60947-3, CEI 17-11 (Fasc. 1039), EN 60947-3, NBN EN 60947-3, NF C 63-130, UL 508 Safety-switch-disconnector (red/yellow) according to DIN VDE 0113 Teil 1

SPECIFICATIONS

SeriesSwitch-disconnectors - DILOS
Conventional enclosed thermal current Ithe = Ith200 A
Number of poles4P
Type of disconnectorSwitch-disconnector
Contact position indicationVisible contact position indication
MountingPanel mounting
Type of Dilos/FulosDILOS 3
400/415V (AC23A/AC23B)200 A
500V (AC23A/AC23B)200 A
690V (AC23A/AC23B)200 A
400/415V (AC22A/AC22B)200 A
500V (AC22A/AC22B)200 A
690V (AC22A/AC22B)200 A
400/415V (AC21A/AC21B)200 A
500V (AC21A/AC21B)200 A
690V (AC21A/AC21B)200 A
110V (DC23A 2P)200 A
250V (DC23A 2P)160 A
250V (DC23A 4P)200 A
Rated operational voltage Ue (V)690 V
Rated impulse withstand voltage (2000 m) Uimp8 kV
StandardsBSNBNEN60947-3;CEI17-11(Fasc.1039);DINVDE0660Teil1;IEC60947-1;IEC60947-3;K63B;NBNEN60947-3;NFC63130
ApprovalsKEMA
Conventional enclosed thermal current lthe200 A
Maximum torque on terminals (Nm)12 Nm
Rated insulation voltage Ui (V)1000 V
Durability (number of operational cycles) electrical1000
Max Rated Operational Power 400/415V (AC23 (kW))88 kW/92 kW
Max Rated Operational Power 500V (AC23 (kW))175 kW
Max Rated Operational Power 690V (AC23 (kW))190 kW
Rated capacity power at 400V (kVAR)97 kVAr
Terminal capacity (Cu-rail mm x mm)Cu-rail 30x6 mm
Rated short circuit making cap Icm (kA peak) Ue = 400V30 kA
Rated short circuit making cap Icm (kA peak) Ue = 415V30 kA
Rated short circuit making cap Icm (kA peak) Ue = 500V30 kA
Rated short circuit making cap Icm (kA peak) Ue = 690V30 kA
Rated short time withstand current Icw (kA rms) 1 s9 kA
Rated short time withstand current Icw (kA rms) 0.25 s15 kA
Durability (number of operational cycles) mech. (min.)10000
Rated Cond S/C current Backup protection kA rms @ 400V100 kA
Rated Cond S/C current Backup protection kA rms @ 415V100 kA
Rated Cond S/C current Backup protection kA rms @ 500V100 kA
Rated Cond S/C current Backup protection kA rms @ 690V100 kA

DIMENSIONS

Weight2.9 kg

CLASSIFICATION

ETIM 5.0EC000216
ETIM 6.0EC000216

Reviews (0)

No customer reviews for the moment.