Dilos 1 - 40A up to 125A

Performance

  • DIN-rail type and wall mounting type
  • Safety-switch-disconnector (main disconnector)
  • Disconnect function
  • Visible contact indication - transparent contact cover
  • Quick make and quick break mechanism
  • Independent opening and closing
  • Positive contact indication (PCI)
  • Double knife contacts - high short-circuit resistance
  • Number of poles 2P - 3P - 4P
  • Box terminals with inbus screws
  • Padlockable
Standards

IEC 60947-1 and IEC 60947-3, DIN VDE 0660 Teil 107,BS EN 60947-3, CEI 17-11 (Fasc. 1039), EN 60947-3, NBN EN 60947-3, NF C 63-130, UL 508 Safety-switch-disconnector (red/yellow) according to DIN VDE 0113 Teil 1

SPECIFICATIONS

SeriesSwitch-disconnectors - DILOS
Conventional enclosed thermal current Ithe = Ith63 A
Number of poles3P
Type of disconnectorSwitch-disconnector
Contact position indicationPositive contact position indication with safety-colors
MountingDIN-rail
Type of Dilos/FulosDILOS 1
400/415V (AC23A/AC23B)50 A
500V (AC23A/AC23B)25 A
690V (AC23A/AC23B)18 A
400/415V (AC22A/AC22B)63 A
500V (AC22A/AC22B)63 A
690V (AC22A/AC22B)50 A
400/415V (AC21A/AC21B)63 A
500V (AC21A/AC21B)63 A
690V (AC21A/AC21B)63 A
110V (DC23A 2P)63 A
250V (DC23A 2P)63 A
Rated operational voltage Ue (V)690 V
Rated impulse withstand voltage (2000 m) Uimp8 kV
StandardsBSNBNEN60947-3;CEI17-11(Fasc.1039);DINVDE0113Teil1;DINVDE0660Teil1;IEC60947-1;IEC60947-3;K63B;NBNEN60947-3;NFC63130
ApprovalsKEMA
Conventional enclosed thermal current lthe63 A
Maximum torque on terminals (Nm)12 Nm
Rated insulation voltage Ui (V)690 V
Durability (number of operational cycles) electrical1500
Max Rated Operational Power 400/415V (AC23 (kW))27 kW/28 kW
Max Rated Operational Power 500V (AC23 (kW))22 kW
Max Rated Operational Power 690V (AC23 (kW))22 kW
Rated capacity power at 400V (kVAR)30 kVAr
Rated short circuit making cap Icm (kA peak) Ue = 400V10 kA
Rated short circuit making cap Icm (kA peak) Ue = 415V10 kA
Rated short circuit making cap Icm (kA peak) Ue = 500V6.7 kA
Rated short circuit making cap Icm (kA peak) Ue = 690V6.7 kA
Rated short time withstand current Icw (kA rms) 1 s3 kA
Rated short time withstand current Icw (kA rms) 0.25 s6 kA
Durability (number of operational cycles) mech. (min.)20000
Terminal capacity (Cu) min/max (mm²)6 mm²/50 mm²
Rated Cond S/C current Backup protection kA rms @ 400V50 kA
Rated Cond S/C current Backup protection kA rms @ 415V50 kA
Rated Cond S/C current Backup protection kA rms @ 500V50 kA
Rated Cond S/C current Backup protection kA rms @ 690V33 kA

DIMENSIONS

Weight0.54 kg

CLASSIFICATION

ETIM 5.0 EC000216
ETIM 6.0 EC000216

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.