  • Function:
    Reducing the voltage to a very low (safety) voltage used mainly as control-voltage in order to reduce the risk of electrocution due to environmental circumstances (i.e. high degree of humidity like outdoors, in a swimming pool complex, etc.)

  • Applications:
    Going from supplying power to a bell circuit, to supplying power to the control circuit of impulse switches, relays or contactors for the control of lighting, heating, etc.

  • Features:
    Safety transformers have short-circuit protection throught PTC or fail-safe transformers and continuous nominal power.
    Bell transformers are recommended for intermittent use at the nominal power declared. Complete noiseless operation.
    4, 8, 12, 24, 48V secondary voltages available at power indicated.
    Trminals are equipped with captive Pozidriv screws and have IP20 protection degree.
    Possibility to connect till 2 loads at lower secondary voltages taking into account the power. For bells and safety transformers over 25VA terminals CAPs available as accesorie with sealing performances.

ORDER/DELIVERY STATUS

StatusActive

SPECIFICATIONS

Family Transformer
Series Series TS+
Power (VA) 40 VA
Voltage (V) 230V 50Hz / 240V 60Hz
Product type Safety transformer
Maximum load (VA) 40 VA
Number of modules 3
Standard packing 1
Primary voltage (V) 230 Vac
Approvals CE
Standards IEC 61558-1-2-6
Isolation voltage (kV) 4 kV
Short-circuit protection PTC
Minimum secondary voltage at nominal load 0.95 x Un sec
Secondary voltage at nominal primary voltage 12/12/24 V
Nominal primary voltage and frequency (Hz) 230V 50Hz / 240V 60Hz
Maximum secondary voltage at zero load 1.3 x Un sec
IP20
Screws Slotted and PH1
Terminal capacity max (mm²) 1 x 4 mm² / 2 x 2.5 mm²
Terminal capacity min (mm²) 1 x 0.5 mm²
User temperature (°C) -20°C / +40°C

DIMENSIONS

Weight 0.8 kg

CLASSIFICATION

ETIM 5.0EC002486
ETIM 6.0EC002486

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.