730470 GENERAL ELECTRIC Safety-switch-disconnector Dilos 3 250A 3P R/Y View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

730470 GENERAL ELECTRIC Safety-switch-disconnector Dilos 3 250A 3P R/Y

730470

GENERAL ELECTRIC

Available

Ship on today

Safety-switch-disconnector Dilos 3 250A 3P R/Y

More details


Residual Current Devices Rcd Ground Fault Circuit Interrupter Gfci Breaker Rccb

Industrial

DIFFERENTIAL PROTECTION

* Brand new product in its original packaging covered by the warranties and certifications provided by GENERAL ELECTRIC

Quantity Price
1+$150.99
2+$146.37
3+$144.16
4+$143.11
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Dilos 3 - 160A up to 315A

Performance

  • Panel mounting
  • Safety-switch-disconnector (main disconnector)
  • Disconnect function
  • Visible contact indication - transparent cover
  • Quick make and quick break mechanism
  • Independent opening and closing
  • Positive contact indication (PCI)
  • Defeat mechanism rotary handle
  • Double knife contacts - high short-circuit resistance
  • Number of poles 3P - 4P
  • With changeover system
Standards

IEC 60947-1 and IEC 60947-3, DIN VDE 0660 Teil 107,BS EN 60947-3, CEI 17-11 (Fasc. 1039), EN 60947-3, NBN EN 60947-3, NF C 63-130, UL 508 Safety-switch-disconnector (red/yellow) according to DIN VDE 0113 Teil 1

SPECIFICATIONS

SeriesSwitch-disconnectors - DILOS
Conventional enclosed thermal current Ithe = Ith250 A
Number of poles3P
Type of disconnectorSwitch-disconnector
Contact position indicationVisible contact position indication with safety-colors
MountingPanel mounting
Type of Dilos/FulosDILOS 3
400/415V (AC23A/AC23B)250 A
500V (AC23A/AC23B)250 A
690V (AC23A/AC23B)200 A
400/415V (AC22A/AC22B)250 A
500V (AC22A/AC22B)250 A
690V (AC22A/AC22B)250 A
400/415V (AC21A/AC21B)250 A
500V (AC21A/AC21B)250 A
690V (AC21A/AC21B)250 A
110V (DC23A 2P)250 A
250V (DC23A 2P)160 A
250V (DC23A 4P)250 A
Rated operational voltage Ue (V)690 V
Rated impulse withstand voltage (2000 m) Uimp8 kV
StandardsBSNBNEN60947-3;CEI17-11(Fasc.1039);DINVDE0113Teil1;DINVDE0660Teil1;IEC60947-1;IEC60947-3;K63B;NBNEN60947-3;NFC63130
ApprovalsKEMA
Conventional enclosed thermal current lthe250 A
Maximum torque on terminals (Nm)12 Nm
Rated insulation voltage Ui (V)1000 V
Durability (number of operational cycles) electrical1000
Max Rated Operational Power 400/415V (AC23 (kW))135 kW/140 kW
Max Rated Operational Power 500V (AC23 (kW))175 kW
Max Rated Operational Power 690V (AC23 (kW))190 kW
Rated capacity power at 400V (kVAR)120 kVAr
Terminal capacity (Cu-rail mm x mm)Cu-rail 30x6 mm
Rated short circuit making cap Icm (kA peak) Ue = 400V30 kA
Rated short circuit making cap Icm (kA peak) Ue = 415V30 kA
Rated short circuit making cap Icm (kA peak) Ue = 500V30 kA
Rated short circuit making cap Icm (kA peak) Ue = 690V30 kA
Rated short time withstand current Icw (kA rms) 1 s9 kA
Rated short time withstand current Icw (kA rms) 0.25 s15 kA
Durability (number of operational cycles) mech. (min.)10000
Rated Cond S/C current Backup protection kA rms @ 400V100 kA
Rated Cond S/C current Backup protection kA rms @ 415V100 kA
Rated Cond S/C current Backup protection kA rms @ 500V100 kA
Rated Cond S/C current Backup protection kA rms @ 690V100 kA

DIMENSIONS

Weight2.75 kg

CLASSIFICATION

ETIM 5.0 EC000216
ETIM 6.0 EC000216

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.