Description:

* Function: Impulse switches are electromechanically controlled switches used to control single- or multi-phase medium-power loads while the control itself can be (very) low power. The device switches between 2 stable positions, each time a (brief) impulse energises its control circuit.

* Application: Mainly used for the switching of lighting and heating equipment and/or to obtain a simplifi ed wiring in case the load needs to be controlled at reduced voltage and/or from more than 2 different places.

* Features: Besides the normal operation through electrically energising the coil, manual operation is possible at all times. The switch position is visualised by the position of the front handle for all devices. The central command version was developed to force several devices at the same time to the on or off position, independently of the current status of each individual device. Also in this case, the possibility of operating the device locally remains. The safety terminals are equipped with captive Pozidriv screws and have IP20 protection degree. An add-on auxiliary contact, add-on central-command module and a spacer are available. The use of a large number of luminous push-buttons is possible. Availability of sealing cap for coil and load terminals.

DIN-rail positioning: used in vertical/horizontal position


Descriptors

Category

Impulse switches

Specifications

Standards

CE, IEC 60669-1, IEC 60669-2-2

Rated current 250 VAC (1pole)/ 440 VAC (2, 3 and 4 pole) (A)

16

Maximum Load AC-1 (A)

16

Maximum Load DC (30V) (A)

16

Maximum coil holding voltage time (h)

1

Coil pick-up power (VA)

18

Coil power loss - AC (VA)

9

Maximum number of impulses per hour

900

Minimum impulse time (at 90% Un) (s)

0.10

Minimum impulse time (under Un) (s)

0.05

Minimum time between impulses (s)

0.15

Ambient temperature at installation point (min./max.) (°C)

-25 / +55

Classifications

ETIM 6.0

EC000188

Package information

Package height (mm)

150

Package width (mm)

72

Package depth (mm)

94

Package weight (kg)

0,145

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.