FGQDB4M/6 431181 GENERAL ELECTRIC FG-RCD DiffBottom-4p 200-440V AC View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

FGQDB4M/6 431181 GENERAL ELECTRIC FG-RCD DiffBottom-4p 200-440V AC

FGQDB4M/6

431181

GENERAL ELECTRIC

Available

Ship on today

FG-RCD DiffBottom-4p 200-440V AC

More details


Residual Current Devices Rcd Ground Fault Circuit Interrupter Gfci Breaker Rccb

Industrial

DIFFERENTIAL PROTECTION

* Brand new product in its original packaging covered by the warranties and certifications provided by GENERAL ELECTRIC

*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



A record plus circuit breaker can offer protection against earth leakage currents by using an add-on residual current device (RCD). A line of four pole completely integrated add-on devices are available as side mounted models (FD frame size) or as units that are fitted below the trip unit of the breaker (FD, FE and FG frame sizes). In all cases the RCD unit interfaces directly with the circuit breaker without the use of any secondary wiring connections. Earth RCD has a sensor placed around the phase and neutral current paths that detects the vectorial sum of the phase and neutral currents. When this sum is no longer zero it is assumed that current is flowing to earth (residual current). If this value exceeds the threshold set on the RCD the breaker connected to the device is tripped.
The RCD unit's electrical power is supplied by the line voltage of the breaker it is linked to. By use of a multi-phase bridge the design still works when one phase and the neutral is present. A pouch on the RCD allows one to place one BAT contact NO or NC which allows a remote signal on earth faults. A Record Plus breaker and an RCD combination can be connected like any stand-alone breaker and are available as fixed or plug-in devices. The mains connection interface of the RCD is an exact replica of the breaker connection area, thus allowing the use of all standard breaker terminals.

ORDER/DELIVERY STATUS

Status Active

SPECIFICATIONS

SeriesResidual Current devices
RangeProtection
Number of poles4P
Frame typeG frame (400A/630A)
Accessory DetailDifferential bottom
Measurements109x183.7x125.4 mm
Standard packing1

DIMENSIONS

Weight6 kg

CLASSIFICATION

ETIM 5.0 EC001021
ETIM 6.0 EC001021