CTX + R161048A 686003 GENERAL ELECTRIC CONTAX-R+relays 16A 1CO 48Vac View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

CTX + R161048A 686003 GENERAL ELECTRIC CONTAX-R+relays 16A 1CO 48Vac

CTX + R161048A

686003

GENERAL ELECTRIC

Available

Ship on today

CONTAX-R+relays 16A 1CO 48Vac

More details


Energy Meters Control Analizers

Residential

ENERGY MANAGEMENT

* Brand new produt in its original packing covered by the warranties and certifications provided by GENERAL ELECTRIC

QuantityPrice
1+40,51 €
4+37,98 €
8+37,07 €
11+36,70 €
15+36,40 €
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info




  • Function:
    Relays are electromechanically controlled switches used to control low power loads.

  • Applications:
    Switching of lighting, heating, etc.
    Galvanic insulation of i.e. status signalisation lamps from a (high) power (high voltage) circuit.
    Galvanic insulation of PLC-inputs or outputs to avoid destruction through excessive voltage.
  • Features:
    The switch position is visualised by the position of the front handle.
    The safety terminals are equipped with captive Pozidriv screws and have IP20 protection degree.
    Add-on auxiliary contacts available.
    Because of the advanced product design, no spacers are needed.
    Increased safety: sealing caps for both coil and terminal are available.

ORDER/DELIVERY STATUS

StatusActive

SPECIFICATIONS

SeriesRelays - Contax R+
Rated switching capacity (A)16A
Contact combination1CO
Coil voltage (V)48 Vac
AC/DCAC
Coil DC/AC factor0.5:1 (24 Vdc)
Standard packing12
StandardsNBN EN 60947-4-1, CE
Number of modules Drive module1
Number of modules With section power contact2
Coil Voltage range (in % from Un)85-110%
Electrical life service Mechanical2 x 106 controls
Operating temperature-20°C / 45°C
Connection of the lamps1.5-10 mm²
Possible volt/phase Fuse rating (gL)20 A
Possible volt for non-compensated fluor-lamps900 VA
Switching on voltage NO contact<0.040 s
Switching on voltage NC contact<0.020 s
Switching off voltage NO or NC contact<0.050 s
Possible volt/phase Max volt AC-1- Operating mod3 kW
Possible volt/phase Max volt AC-1- Contactbloc8.5 kW
Possible volt/phase Max volt AC-1- Max volt AC-5b1.8 kW
Possible volt/phase Max volt AC-7b- Operating mod0.9 kW
Possible volt/phase Max volt AC-3- Contatcbloc1.5 kW/250V 2.2kW/400V
Possible volt/phase Min volt per phase (at 5V)2 W
Possible volt- sockets & incandes lamps (40 to 200W)1800 W
Possible volt for compensated fluor-lamps- Serie1800 VA
Possible volt for compensated fluor-lamps- Parallel500 VA
Electrical life service Electrical at full voltage AC-13 x 105 controls
Coil power-loss - AC1.8 VA
Coil power-loss - DC2.1 W
Coil pick-up power (AC)3.4 VA

DIMENSIONS

Weight0.116 kg

CLASSIFICATION

ETIM 5.0EC001652
ETIM 6.0EC001652

Reviews (0)

No customer reviews for the moment.