731755 GENERAL ELECTRIC Changeover switch-disconnector Dilos 8S 2000A 3P+N (N 50%) View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

731755 GENERAL ELECTRIC Changeover switch-disconnector Dilos 8S 2000A 3P+N (N 50%)

731755

GENERAL ELECTRIC

Available

Ship on today

Changeover switch-disconnector Dilos 8S 2000A 3P+N (N=50%)

More details


Electric Relays Switch

Industrial

Relays and toroidal

* Brand new product in its original packaging covered by the warranties and certifications provided by GENERAL ELECTRIC

*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Dilos 8S - 2000A/2500A

Performance

  • Panel mounting
  • Safety-switch-disconnector (main disconnector)
  • Disconnect function
  • Visible contact indication - transparent cover
  • Quick make and quick break mechanism
  • Independent opening and closing
  • Positive contact indication (PCI)
  • Double knife contacts - high short-circuit resistance
  • Number of poles
    • 3P - 4P = changeover
    • 6P = 6P Dilos


IEC 60947-1 and IEC 60947-3, DIN VDE 0660 Teil 107, DIN VDE 0113 Teil 1, BS EN 60947-3, CEI 17-11 (Fasc. 1039), EN 60947-3, NBN EN 60947-3, NF C 63-130


SPECIFICATIONS

SeriesSwitch-disconnectors - DILOS
Conventional enclosed thermal current Ithe = Ith2000 A
Number of poles3P+N
Type of disconnectorSwitch-disconnector with Manual changeover
Contact position indicationVisible contact position indication
MountingPanel mounting
Type of Dilos/FulosDILOS 8S
400/415V (AC23A/AC23B)1250 A
500V (AC23A/AC23B)800 A
690V (AC23A/AC23B)630 A
400/415V (AC22A/AC22B)2000 A
500V (AC22A/AC22B)1250 A
690V (AC22A/AC22B)1000 A
400/415V (AC21A/AC21B)2000 A
500V (AC21A/AC21B)2000 A
690V (AC21A/AC21B)2000 A
110V (DC23A 2P)800 A
250V (DC23A 2P)800 A
Rated operational voltage Ue (V)1000 V
Rated impulse withstand voltage (2000 m) Uimp8 kV
StandardsBSNBNEN60947-3;CEI17-11(Fasc.1039);DINVDE0660Teil1;IEC60947-1;IEC60947-3;K63B;NBNEN60947-3;NFC63130
ApprovalsKEMA pending
Conventional enclosed thermal current lthe2000 A
Maximum torque on terminals (Nm)35 Nm
Rated insulation voltage Ui (V)1500 V
Durability (number of operational cycles) electrical500
Rated capacity power at 400V (kVAR)850 kVAr
Terminal capacity (Cu-rail mm x mm)Cu-rail 2x80x10 mm
Rated short circuit making cap Icm (kA peak) Ue = 400V105 kA
Rated short circuit making cap Icm (kA peak) Ue = 415V105 kA
Rated short time withstand current Icw (kA rms) 1 s50 kA
Rated short time withstand current Icw (kA rms) 0.25 s120 kA
Durability (number of operational cycles) mech. (min.)2500
Rated Cond S/C current Backup protection kA rms @ 400V50 kA
Rated Cond S/C current Backup protection kA rms @ 415V50 kA

DIMENSIONS

Weight61 kg

CLASSIFICATION

ETIM 5.0 EC000216
ETIM 6.0 EC000216

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.