Product successfully added to your shopping cart
D661367255
731602
GENERAL ELECTRIC
1
Changeover switch-disconnector Dilos 6S 1250A 3P 50kA
Industrial > DIFFERENTIAL PROTECTION
* Brand new product in its original packaging covered by the warranties and certifications provided by GENERAL ELECTRIC
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Dilos 6S - 800A up to 1250A
Performance
Series | Switch-disconnectors - DILOS |
Conventional enclosed thermal current Ithe = Ith | 1250 A |
Number of poles | 3P |
Type of disconnector | Switch-disconnector with Manual changeover |
Contact position indication | Visible contact position indication |
Mounting | Panel mounting |
Type of Dilos/Fulos | DILOS 6S |
400/415V (AC23A/AC23B) | 1250 A |
500V (AC23A/AC23B) | 800 A |
690V (AC23A/AC23B) | 630 A |
400/415V (AC22A/AC22B) | 1250 A |
500V (AC22A/AC22B) | 1250 A |
690V (AC22A/AC22B) | 1250 A |
400/415V (AC21A/AC21B) | 1250 A |
500V (AC21A/AC21B) | 1250 A |
690V (AC21A/AC21B) | 1250 A |
110V (DC23A 2P) | 1250 A |
250V (DC23A 2P) | 1000 A |
Rated operational voltage Ue (V) | 1000 V |
Rated impulse withstand voltage (2000 m) Uimp | 12 kV |
Standards | BSNBNEN60947-3;CEI17-11(Fasc.1039);DINVDE0660Teil1;IEC60947-1;IEC60947-3;K63B;NBNEN60947-3;NFC63130 |
Approvals | KEMA pending |
Conventional enclosed thermal current lthe | 1250 A |
Maximum torque on terminals (Nm) | 35 Nm |
Rated insulation voltage Ui (V) | 1500 V |
Durability (number of operational cycles) electrical | 1000 |
Rated capacity power at 400V (kVAR) | 600 kVAr |
Terminal capacity (Cu-rail mm x mm) | Cu-rail 2x50x8 mm |
Rated short circuit making cap Icm (kA peak) Ue = 400V | 105 kA |
Rated short circuit making cap Icm (kA peak) Ue = 415V | 105 kA |
Rated short time withstand current Icw (kA rms) 1 s | 50 kA |
Rated short time withstand current Icw (kA rms) 0.25 s | 100 kA |
Durability (number of operational cycles) mech. (min.) | 4000 |
Rated Cond S/C current Backup protection kA rms @ 400V | 50 kA |
Rated Cond S/C current Backup protection kA rms @ 415V | 50 kA |
Weight | 35 kg |
ETIM 5.0 | EC000216 |
ETIM 6.0 | EC000216 |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.