DILM9-10(120VDC) 158226 EATON MOELLER XTCE009B10AD Contactor, 4 kW/400 V, DC operated View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

DILM9-10(120VDC) 158226 EATON MOELLER XTCE009B10AD Contactor, 4 kW/400 V, DC operated

DILM9-10(120VDC)

158226

EATON - MOELLER

Available

Ship on today

XTCE009B10AD Contactor, 4 kW/400 V, DC operated

More details


* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Delivery programme
Product range
  Contactors
Application
  Contactors for Motors
Subrange
  Contactors up to 170 A, 3 pole
Utilization category
  AC-1: Non-inductive or slightly inductive loads, resistance furnaces
NAC-3: Normal AC induction motors: starting, switch off during running
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
 
  border=1>>border=1>
Notes
  Also suitable for motors with efficiency class IE3.
IE3-ready devices are identified by the logo on their packaging.
Connection technique
  Screw terminals
Pole
  3 pole
Rated operational current
   
AC-3
   
380 V 400 V
IeA9
AC-1
   
Conventional free air thermal current, 3 pole, 50 - 60 Hz
   
Open
   
at 40 °C
Ith =IeA22
enclosed
IthA18
Conventional free air thermal current, 1 pole
   
open
IthA50
enclosed
IthA45
Max. rating for three-phase motors, 50 - 60 Hz
   
AC-3
   
220 V 230 V
PkW2.5
380 V 400 V
PkW4
660 V 690 V
PkW4.5
AC-4
   
220 V 230 V
PkW1.5
380 V 400 V
PkW2.5
660 V 690 V
PkW3.6
Contacts
   
N/O = Normally open
  1 N/O
Contact sequence
  border=1>>border=1>
Instructions
  Contacts to EN 50 012.
Integrated varistor suppressor circuit.
Can be combined with auxiliary contact
  DILM32-XHI..
DILA-XHI(V)..
Voltage AC/DC
  DC operation
Technical data
General
Standards
  IEC/EN 60947, VDE 0660, UL, CSA
Lifespan, mechanical
   
AC operated
Operationsx 10610
DC operated
Operationsx 10610
Operating frequency, mechanical
   
AC operated
Operations/h 5000
DC operated
Operations/h 5000
Climatic proofing
  Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature
   
Open
 °C-25 - +60
Enclosed
 °C- 25 - 40
Storage
 °C- 40 - 80
Mounting position
  border=1>>border=1>border=1>>border=1>
Mechanical shock resistance (IEC/EN 60068-2-27)
   
Half-sinusoidal shock, 10 ms
   
Main contacts
   
N/O contact
 g10
Auxiliary contacts
   
N/O contact
 g7
N/C contact
 g5
Mechanical shock resistance (IEC/EN 60068-2-27) when tabletop-mounted
   
Half-sinusoidal shock, 10 ms
   
Main contacts
   
N/O contact
 g5.7
Auxiliary contacts
   
N/O contact
 g3.4
N/C contact
 g3.4
Degree of Protection
  IP20
Protection against direct contact when actuated from front (EN 50274)
  Finger and back-of-hand proof
Weight
   
AC operated
 kg0.23
DC operated
 kg0.28
Terminal capacity main cable
   
Solid
 mm21 x (0.75 - 4)
2 x (0.75 - 2.5)
Flexible with ferrule
 mm21 x (0.75 - 2.5)
2 x (0.75 - 2.5)
 
  Also without ferrule.
Solid or stranded
 AWG18 - 10
Main cable connection screw/bolt
  M3.5
Tightening torque
 Nm1.2
Control circuit cable connection screw/bolt
  M3.5
Tightening torque
 Nm1.2
Tool
   
Main cable
   
Pozidriv screwdriver
 Size2
Standard screwdriver
 mm0.8 x 5.5
1 x 6
Control circuit cables
   
Pozidriv screwdriver
 Size2
Standard screwdriver
 mm0.8 x 5.5
1 x 6
Main conducting paths
Rated impulse withstand voltage
UimpV AC8000
Overvoltage category/pollution degree
  III/3
Rated insulation voltage
UiV AC690
Rated operational voltage
UeV AC690
Safe isolation to EN 61140
   
between coil and contacts
 V AC400
between the contacts
 V AC400
Making capacity (p.f. to IEC/EN 60947)
   
 
Up to 690 VA126
Breaking capacity
   
220 V 230 V
 A90
380 V 400 V
 A90
500 V
 A70
660 V 690 V
 A50
Short-circuit rating
   
Short-circuit protection maximum fuse
   
Type “2” coordination
   
400 V
gG/gL 500 VA20
690 V
gG/gL 690 VA16
Type “1” coordination
   
400 V
gG/gL 500 VA35
690 V
gG/gL 690 VA20
AC
AC-1
   
Rated operational current
   
Conventional free air thermal current, 3 pole, 50 - 60 Hz
   
Open
   
at 40 °C
Ith =IeA22
at 50 °C
Ith =IeA21
at 55 °C
Ith =IeA21
at 60 °C
Ith =IeA20
enclosed
IthA18
Conventional free air thermal current, 1 pole
   
open
IthA50
enclosed
IthA45
AC-3
   
Rated operational current
   
Open, 3-pole: 50 – 60 Hz
   
220 V 230 V
IeA9
240 V
IeA9
380 V 400 V
IeA9
415 V
IeA9
440V
IeA9
500 V
IeA7
660 V 690 V
IeA5
380 V 400 V
IeA9
Motor rating
PkWh 
220 V 230 V
PkW2.5
240V
PkW3
380 V 400 V
PkW4
415 V
PkW5.5
440 V
PkW5.5
500 V
PkW4.5
660 V 690 V
PkW4.5
AC-4
   
Open, 3-pole: 50 – 60 Hz
   
220 V 230 V
IeA6
240 V
IeA6
380 V 400 V
IeA6
415 V
IeA6
440 V
IeA6
500 V
IeA5
660 V 690 V
IeA4.5
Motor rating
PkWh 
220 V 230 V
PkW1.5
240 V
PkW1.6
380 V 400 V
PkW2.5
415 V
PkW2.8
440 V
PkW3
500 V
PkW2.8
660 V 690 V
PkW3.6
DC
Rated operational current, open
   
DC-1
   
60 V
IeA20
110 V
IeA20
220 V
IeA15
440 V
IeA1.3
DC-3
   
60 V
IeA20
110 V
IeA20
220 V
IeA1.5
440 V
IeA0.2
DC-5
   
60 V
IeA20
110 V
IeA20
220 V
IeA1.5
440 V
IeA0.2
Current heat loss
3-pole at Ith
 W4.5
Current heat loss at Ie to AC-3/400 V
 W0.9
Impedance per pole
 mΩ4.6
Magnet systems
Voltage tolerance

Datasheet - PDF

Title:Language:Size:Type:
EATON MOELLER-158226-DILM9-10(120VDC)English623 KbytesEATON MOELLER-158226-DILM9-10(120VDC)

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review