XN-322-12DO-P17 178788 EATON ELECTRIC Digital output module 12 digital outputs short-circuit proof 24 V DC/1.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

XN-322-12DO-P17 178788 EATON ELECTRIC Digital output module 12 digital outputs short-circuit proof 24 V DC/1..

XN-322-12DO-P17

178788

EATON-MOELLER

Digital output module; 12 digital outputs short-circuit proof 24 V DC/1.7 A each; pulse-switching

XN-322-12DO-P17

More details


PLC's > Fieldbus, decentr. periphery - digital I/O module

Remote I / O Modules XN300

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $230.05
Unit price: $230.05

Quantity Price
1+$230.05
2+$200.95
3+$189.10
4+$182.40
6+$177.24
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Digital output module; 12 digital outputs short-circuit proof 24 V DC/1.7 A each; pulse-switching
Analog input module with eight 0-20 mA / 4-20 mA current inputs. +/- 0.5% G.v.EW, measurement indication in uA, 16Bit (0.3uA resolution)

Delivery program

Function
XN300 I/O slice modules
Connection technique
Push-in spring-cage terminal
Function
XN-322 digital output module for XN300
Short Description
12 digital outputs short-circuit proof 24 V DC/1.7 A each, pulse-switching
For use with
XN-312-…

Technical data

General
Standards
IEC/EN 61131-2
IEC/EN 61000-6-2
IEC/EN 61000-6-4
ApprovalsApprovals
CE, cULus
EAC
Approvalsshipping classification
DNV GL
Approvals
0000SPC-637
Electromagnetic compatibility (EMC)ESD [Air/contact discharge]
8 / 4 kV
Electromagnetic compatibility (EMC)Electromagnetic fields [(0.08…1) / (1,4…2) / (2…2,7) GHz ]
10 / 3 / 1 V/m
Electromagnetic compatibility (EMC)BurstSupply cable
2 kV
Electromagnetic compatibility (EMC)BurstSignal cable
1 kV
Electromagnetic compatibility (EMC)SurgeSupply cable (balanced / unbalanced)
0,5 / 0,5 kV
Electromagnetic compatibility (EMC)SurgeSignal cable (unbalanced)
1 kV
Electromagnetic compatibility (EMC)Radiated RFI
10 V
Electromagnetic compatibility (EMC)Emitted interference (radiated, high frequency) [(30...230 MHz) / (230...1000 MHz)]
40 / 47 class A dB
Electromagnetic compatibility (EMC)Voltage fluctuations/voltage dips
Yes / 10 ms
Ambient conditionsClimatic conditionsClimatic proofing
Dry heat to IEC 60068-2-2
Damp heat as per EN 60068-2-3
Ambient conditionsClimatic conditionsAir pressure (operation)
795 - 1080 hPa
Ambient conditionsClimatic conditionsRelative humidity
0 - 95%, non condensing
Ambient conditionsClimatic conditionsCondensation
prevent with suitable measures
Ambient conditionsTemperatureOperation
0 - +55 °C
Ambient conditionsTemperatureStorage, transport [ϑ]
-20 - +85 °C
Degree of Protection
IP20
Mounting position
Horizontal
Free fall, packaged (IEC/EN 60068-2-32)
1 m
Vibrations [3,5 mm / 1 g]
5 - 8.4 / 8.4 -150 Hz
Mechanical shock resistance [Semisinusoidal 15 g/11 ms]
18 Impacts
Terminations
Rated operational dataInsulating material group
I
Rated operational dataOvervoltage category / pollution degree
III / 3
Rated operational dataRated operating voltage
160 V
Rated operational dataMaximum load current/cross-sectional area
X (not specified by plug manufacturer) A / mm²
Connection design in TOP direction
Push-in spring-cage terminal (plug-in connection)
Stripping length
10 mm
Gauge pin IEC/EN 60947-1
A1
Connection specifications"e" solid H07V-U
0.2 - 1.5 mm2
Connection specifications"f" flexible H 07V-K
0.2 - 1.5 mm2
Connection specifications"f" with ferrules without plastic collar according to DIN 46228-1 (ferrules crimped gas-tight)
0.25-1,5 mm2
Connection specifications"f" with ferrules with plastic collar according to DIN 46228-1 (ferrules crimped gas-tight)
0.25-1,5 mm2
Connection specificationsCable size
24 - 16 AWG
Supply
Power supply - InputPower supplyCurrent consumption for +5 V power supply (internal) [I]
(typ.)45 mA
Power supply - InputPower supplyCurrent consumption for +24 V power supply [I]
(typ.)none mA
Power supply - InputPower supplyPotential isolation [PE (polyethylene)]
no
Power supply - InputPower supplyRated operating voltage [Ue]
24 (terminal +1) V
Power supply - InputPower supplyRated operational current [Ie]
3.4 A
Power supply - InputPower supplyPotential isolation
no
Power supply - InputPower supplyRated operating voltage [Ue]
24 (terminal +2) V
Power supply - InputPower supplyRated operational current [Ie]
3.4 A
Power supply - InputPower supplyPotential isolation
no
Power supply - InputPower supplyRated operating voltage [Ue]
24 (terminal +3) V
Power supply - InputPower supplyRated operational current [Ie]
3.4 A
Power supply - InputPower supplyPotential isolation
no
Heat dissipationHeat dissipation (without active channels)
0.25 W
Heat dissipationMax. heat dissipation
3.529 W
Heat dissipationNotes on heat dissipation
The max. heat dissipation is specified as the maximum power produced inside the device's housing.
Digital outputs
Channels
12 Quantity
Output voltageOutput voltage, nominal value [Ua]
24 V DC
Output voltageLow level [UaL]
0V < UaL< 1V V
Output voltageHigh level [UaH]
Ue - 1V < UaH< Ue V
Output currentOutput current, nominal value [IaL]
1.7 A
Output currentLow signal [IA]
0 < IaL< 0.5 mA
Output currentHigh level [IaH]
0 ≤ IaH≤ 1700 mA
Short-circuit rating
Yes
Potential isolation
no Output against output
Heat dissipation (internal, per active channel)
0.383 W
Utilization factor [%]
50% (Ʃ IAmax = 10.2A) g
Delay on signal change and resistive loadfrom Low to High level
< 200 µs
Delay on signal change and resistive loadFrom High to Low signal
< 200 µs
Resistive loadResistive load
> 14,1 Ω
Notes on digital outputs
Protective devices must be installed directly at the inductive load in order to prevent interference.

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
0 A
Heat dissipation per pole, current-dependent [Pvid]
0 W
Equipment heat dissipation, current-dependent [Pvid]
0 W
Static heat dissipation, non-current-dependent [Pvs]
3.529 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
0 °C
Operating ambient temperature max.
+55 °C
Degree of Protection
IP20
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Meets the product standard's requirements.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 7.0

PLC's (EG000024) / Fieldbus, decentr. periphery - digital I/O module (EC001599)
Electric engineering, automation, process control engineering / Control / Field bus, decentralized peripheral / Field bus, decentralized peripheral - digital I/O module ([email protected] [BAA055014])
Supply voltage AC 50 Hz
0 - 0 V
Supply voltage AC 60 Hz
0 - 0 V
Supply voltage DC
18 - 30 V
Voltage type of supply voltage
DC
Number of digital inputs
0
Number of digital outputs
12
Digital inputs configurable
No
Digital outputs configurable
No
Input current at signal 1
0 mA
Permitted voltage at input
0 - 0 V
Type of voltage (input voltage)
DC
Type of digital output
Other
Output current
0.5 A
Permitted voltage at output
0 - 29 V
Type of output voltage
DC
Short-circuit protection, outputs available
Yes
Number of HW-interfaces industrial Ethernet
0
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces parallel
0
Number of HW-interfaces Wireless
0
Number of HW-interfaces USB
0
Number of HW-interfaces other
1
With optical interface
No
Supporting protocol for TCP/IP
No
Supporting protocol for PROFIBUS
No
Supporting protocol for CAN
No
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for KNX
No
Supporting protocol for MODBUS
No
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
No
Radio standard Bluetooth
No
Radio standard WLAN 802.11
No
Radio standard GPRS
No
Radio standard GSM
No
Radio standard UMTS
No
IO link master
No
System accessory
Yes
Degree of protection (IP)
IP20
Type of electric connection
Screw-/spring clamp connection
Time delay at signal exchange
0 - 0.1 ms
Fieldbus connection over separate bus coupler possible
Yes
Rail mounting possible
Yes
Wall mounting/direct mounting
No
Front build in possible
No
Rack-assembly possible
No
Suitable for safety functions
No
Category according to EN 954-1
None
SIL according to IEC 61508
None
Performance level acc. EN ISO 13849-1
None
Appendant operation agent (Ex ia)
No
Appendant operation agent (Ex ib)
No
Explosion safety category for gas
None
Explosion safety category for dust
None
Width
16.8 mm
Height
104.2 mm
Depth
80.3 mm

Approvals

Product Standards
CE, cULus
UL File No.
E135462

Dimensions

2723DIM-43
Notes: The plugs/connectors used depend on the version.

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.