PFDM-125/2/03 249033 EATON ELECTRIC 249033 PFDM-125/2/03 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PFDM-125/2/03 249033 EATON ELECTRIC 249033 PFDM-125/2/03

PFDM-125/2/03

249033

EATON-MOELLER

Residual current circuit breaker (RCCB), 125A, 2p, 300mA, type AC

More details


Modular Switchgear – Industrial

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Residual current circuit breaker (RCCB), 125A, 2p, 300mA, type AC
Modern residual current circuit-breaker for rated 125 A current range, for fault and additional protection, Auxiliary contact, selective part no.Suitable for use in the free (on-site power and outdoor distribution board) to -25 °C, mains-voltage-independent tripping, can be used for people and additional protection
[

Design verification as per IEC/EN 61439

Rated operational current for specified heat dissipation [In]
125 A
Heat dissipation per pole, current-dependent [Pvid]
0 W
Equipment heat dissipation, current-dependent [Pvid]
30 W
Static heat dissipation, non-current-dependent [Pvs]
0 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+60 °C
Starting at 40 °C, the max. permissible continuous current decreases by 1.8% for every 1 °C
,

Technical data ETIM 7.0

Circuit breakers and fuses (EG000020) / Residual current circuit breaker (RCCB) (EC000003)
Electric engineering, automation, process control engineering / Electrical installation, device / Residual current protection system / Residual current circuit breaker (RCCB) ([email protected] [AAB906014])
Number of poles
2
Rated voltage
230 V
Rated current
125 A
Rated fault current
300 mA
Rated insulation voltage Ui
400 V
Rated impulse withstand voltage Uimp
4 kV
Mounting method
DIN rail
Leakage current type
AC
Selective protection
No
Short-time delayed tripping
No
Short-circuit breaking capacity (Icw)
10 kA
Surge current capacity
0.2 kA
Frequency
50 Hz
Additional equipment possible
Yes
With interlocking device
Yes
Degree of protection (IP)
IP20
Width in number of modular spacings
2
Built-in depth
71.5 mm
Ambient temperature during operating
-25 - 40 °C
Pollution degree
2
Connectable conductor cross section multi-wired
1.5 - 16 mm²
Connectable conductor cross section solid-core
1.5 - 50 mm²
]

Datasheet - PDF

Title: Size: Type:
PDF EATON XEFFECT SWITCHGEAR RANGE EN.pdf 8 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.