DILM12-XSPR240 281200 XTCEXRSBB EATON ELECTRIC RC suppressor circuit, 110-240VAC, for DILA, DILM7-12 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

DILM12-XSPR240 281200 XTCEXRSBB EATON ELECTRIC RC suppressor circuit, 110-240VAC, for DILA, DILM7-12

DILM12-XSPR240

281200

XTCEXRSBB

EATON-MOELLER

RC suppressor circuit, 110-240VAC, for DILA, DILM7-12

DILM12-XSPR240

More details


Low-voltage industrial components > Surge protection module

KDIL Accessories

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $11.49
Unit price: $11.49

Quantity Price
1+$11.49
2+$11.49
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Often bought together

More info



RC suppressor circuit, 110-240VAC, for DILA, DILM7-12
RC suppressor circuit, Accessories: Suppressor circuit, Voltage: Us 110 - 240 AC V, For use with: DILM7 - DILM15, DILMP20, DILA

General specifications
Product name
Eaton Moeller® series DILM RC suppressor circuit
Part no.
DILM12-XSPR240
EAN
4015082812003
Product Length/Depth
48 millimetre
Product height
25 millimetre
Product width
9 millimetre
Product weight
0.005 kilogram
Certifications
UL Recognized
UL Category Control No.: NKCR2, NKCR8
UL File No.: E29184
CSA File No.: 256465
CSA-C22.2 No. 14-05
CE
CSA
CSA Class No.: 3211-07
IEC/EN 60947-4-1
UL 508
Product Tradename
DILM
Product Type
Accessory
Product Sub Type
RC suppressor circuit
Catalog Notes
With DC operated contactors and with DILM115 and DILM150 the suppressor is integrated.
Features & Functions
Functions
RC-element
General information
Product category
Accessories
Used with
DILM12-XSPR240
Voltage type
AC
Climatic environmental conditions
Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
60 °C
Magnet system
Rated control supply voltage (Us) at AC, 50 Hz - min
110 V
Rated control supply voltage (Us) at AC, 50 Hz - max
240 V
Rated control supply voltage (Us) at AC, 60 Hz - min
110 V
Rated control supply voltage (Us) at AC, 60 Hz - max
240 V
Rated control supply voltage (Us) at DC - min
0 V
Rated control supply voltage (Us) at DC - max
0 V
Design verification
Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 9.0

Low-voltage industrial components (EG000017) / Surge protection module (EC000683)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Contactor (LV) / Component for protective circuit (ecl@ss13-27-37-10-10 [AKF019018])
Function
RC-element
Voltage type (operating voltage)
AC
Operating voltage AC 50 Hz
110 - 240 V
Operating voltage AC 60 Hz
110 - 240 V
Operating voltage DC
0 - 0 V
With LED indication
No

Datasheet - PDF

Reviews (1)

  • M Claraluz Deydania
    Customer rating:
  • Page:1
    Add Review
    hide form
    Rating:
    Name:
    Email:
    Subject:
    Text:
      Captcha
      Add review

    All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.