RAMO-W02AI1S-C320S1 150153 EATON ELECTRIC Reversing starter, 400 V AC, 3-phase, 6.6 A, Control voltage exter.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

RAMO-W02AI1S-C320S1 150153 EATON ELECTRIC Reversing starter, 400 V AC, 3-phase, 6.6 A, Control voltage exter..

RAMO-W02AI1S-C320S1

150153

EATON-MOELLER

Reversing starter, 400 V AC, 3-phase, 6.6 A, Control voltage external brake (50/60 Hz): 230/277 V AC, S-7.4 for 31 modules

Reversing starter, 6.6 A, 230/277 V AC, AS-Interface®, S-7.4 for 31 modules

More details


Low-voltage industrial components > Motor starter/Motor starter combination

Rapid Link Starters

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Reversing starter, 6.6 A, 230/277 V AC, AS-Interface®, S-7.4 for 31 modules
Reversing starter, Product range: motor starter, Description: Integrated thermistor monitoring PTC and thermo-click, Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation, Connections pluggable in power section, Connection of supply voltage via adapter cable on round or flexible busbar junction, Diagnostics and reset on device and via AS-Interface, with AUTO - OFF/RESET - HAND key switches, With electronic motor protection for allocated motor power from 0.09 – 3.0 kW (400 V)/0.125 – 3.0 HP (480 V), without manual override switch, Rated operational voltage: Ue= 400 V AC, 3-phase, 480 V AC, 3-phase, Output voltage with Ve: U2= 400 V AC, 3-phase, Mains voltage (50/60Hz): ULN= 380 (-15%) - 480 (+10%) V, At 150% overload: Ie= 6.6 A, Control voltage external brake (50/60 Hz): 230/277 V AC, Mains voltage (50/60Hz): ULN= 380 (-15%) - 480 (+10%) V, assigned motor rating P Note: at 400 V, 50 Hz, 150 % Overload: P= 0,09 - 3 kW, assigned motor rating P Note: at 480 V, 60 Hz, 150 % Overload: P= 0,125 - 3 HP, assigned motor rating P Note: for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz, AS-Interface profile cable: S-7.4 for 31 modules, Standards: IEC/EN 60947-4-2, UL 60947-4-2, Guideline 2011/65/EU (RoHS), CE approval, UL approval, CCC approval, Degree of Protection: IP65, NEMA12

Delivery program

This item is only available until 06/30/2020, after which it will be replaced with the following item: Y7-198531, RAMO5-W202A31-5120S1
Product range
Motor starter
Basic function
Reversing starter
Rated operational voltage [Ue]
400 V AC, 3-phase
480 V AC, 3-phase
Output voltage with Ve[U2]
= ULN
Mains voltage (50/60Hz) [ULN]
380 (-15%) - 480 (+10%) V
At 150% overload [Ie]
6.6 A
assigned motor rating P
Note
at 400 V, 50 Hz
150 % Overload [P]
0,09 - 3 kW
Note
at 480 V, 60 Hz
150 % Overload [P]
0,125 - 3 HP
Note
for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1at 50 Hz or 1800 min-1at 60 Hz
Description
Integrated thermistor monitoring PTC and thermo-click
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
Connections pluggable in power section
Connection of supply voltage via adapter cable on round or flexible busbar junction
Diagnostics and reset on device and via AS-Interface
with AUTO - OFF/RESET - HAND key switches
With electronic motor protection for allocated motor power from 0.09 – 3.0 kW (400 V)/0.125 – 3.0 HP (480 V)
Control voltage external brake (50/60 Hz)
230/277 V AC V
Interface/field bus (built-in)
AS-Interface®
AS-Interface profile cable
S-7.4 for 31 modules
Instructions
for actuation of motors with mechanical brake

Technical data

General
Standards
IEC/EN 60947-4-2
UL 60947-4-2
Guideline 2011/65/EU (RoHS)
CE approval
UL approval
CCC approval
Climatic proofing [ρw]
< 95%, non-condensing
IEC/EN 50178 %
Ambient temperatureOperating ambient temperature min.
-10 °C
Ambient temperatureOperating ambient temperature max.
+55 °C
Ambient temperatureStorage [ϑ]
-30 - +70 °C
Overvoltage category
III
Rated impulse withstand voltage [Uimp]
4 kV
Radio interference levelEnvironment (EMC)
Device class A
Radio interference levelmaximum motor cable length [I]
10 m
Mechanical shock resistance
1000 shocks per shaft, semi-sinusoidal 15 g/11 ms
IEC/EN 60068-2-27 g
Vibration
Oscillation frequency: 10 - 150 Hz
Amplitude 0.15 mm: 6 Hz
Amplitude transition frequency on acceleration: 57 Hz
IEC/EN 60068-2-6
Mounting position
Vertical
Altitude
0 - 1000 m above sea level
above 1000 m with 1 % performance reduction per 100 m
max. 2000 m m
Degree of Protection
IP65
NEMA12
Main circuit
SupplyRated operational voltage [Ue]
400 V AC, 3-phase
480 V AC, 3-phase
SupplyMains voltage (50/60Hz) [ULN]
380 (-15%) - 480 (+10%) V
SupplyInput current (150% overload) [ILN]
6.6 A
SupplySystem configuration
AC voltage
Center-point earthed star network (TN-S network)
Phase-earthed AC supply systems are not permitted.
SupplySupply frequency [fLN]
50/60 Hz
SupplyFrequency range [fLN]
47 - 63 Hz (± 0%) Hz
SupplyMains switch-on frequency
Maximum of one time every 60 seconds
SupplyRated conditional short-circuit current [Iq]
< 10 kA
SupplyShort-circuit protection for output circuits, external
Type 1 coordination via the power bus' feeder unit
Power sectionFunction
Reversing starter with relays, thyristors and bypass contacts, 2-phase controlled
Power sectionOn-delay [tON]
20 - 35 ms
Power sectionOff-delay [tOFF]
20 - 35 ms
Power sectionLifespan, mechanical [Operations]
AC3: > 10.000.000
Power sectionLifespan, electrical [Operations]
AC3: > 10.000.000
Power sectionOverload cycle
AC-53a
Power sectionOutput voltage with Ve[U2]
= ULN
Power sectionOutput Frequency [f2]
= fLNHz
Power sectionRated operational currentAt 150% overload [Ie]
6.6 A
Power sectionMotor current limit [I]
0.3 - 6.6
adjustable A
Power sectionFitted with
without manual override switch
Motor feederNote
for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1at 50 Hz or 1800 min-1at 60 Hz
Motor feederNote
at 400 V, 50 Hz
Motor feederNote
at 480 V, 60 Hz
Motor feederActuator for external motor brakeBreaking voltage [U]
230/277 V AC -15% / +10% V
Motor feederActuator for external motor brakeBraking current [I]
≤ 0.6 A
(max. 6 A for 120 ms) A
Control section
External control voltage [Uc]
24 V DC - 15 % / + 20 % via AS-Interface®plug V
Interface/field bus (built-in)
AS-Interface®
AS-Interface®
max. total power consumption from AS-Interface® power supply unit (30 V): 250 mA
Specification: S-7.4
Number of slave addresses: 31

Design verification as per IEC/EN 61439

Operating ambient temperature min.
-10 °C
Operating ambient temperature max.
+55 °C

Technical data ETIM 7.0

Low-voltage industrial components (EG000017) / Motor starter/Motor starter combination (EC001037)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Load breakout, motor breakout / Motor starter combination ([email protected] [AJZ718013])
Kind of motor starter
Reversing starter
With short-circuit release
Yes
Rated control supply voltage Us at AC 50HZ
0 - 0 V
Rated control supply voltage Us at AC 60HZ
0 - 0 V
Rated control supply voltage Us at DC
0 - 0 V
Voltage type for actuating
AC
Rated operation power at AC-3, 230 V, 3-phase
0 kW
Rated operation power at AC-3, 400 V
3 kW
Rated power, 460 V, 60 Hz, 3-phase
2.238 kW
Rated power, 575 V, 60 Hz, 3-phase
0 kW
Rated operation current Ie
6.6 A
Rated operation current at AC-3, 400 V
6.6 A
Overload release current setting
0.3 - 6.6 A
Rated conditional short-circuit current, type 1, 480 Y/277 V
65000 A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0 A
Rated conditional short-circuit current, type 2, 230 V
0 A
Rated conditional short-circuit current, type 2, 400 V
0 A
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Ambient temperature, upper operating limit
55 °C
Temperature compensated overload protection
Yes
Release class
CLASS 10
Type of electrical connection of main circuit
Other
Type of electrical connection for auxiliary- and control current circuit
Other
Rail mounting possible
No
With transformer
No
Number of command positions
2
Suitable for emergency stop
No
Coordination class according to IEC 60947-4-3
Class 1
Number of indicator lights
0
External reset possible
Yes
With fuse
No
Degree of protection (IP)
IP65
Degree of protection (NEMA)
12
Supporting protocol for TCP/IP
No
Supporting protocol for PROFIBUS
No
Supporting protocol for CAN
No
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
Yes
Supporting protocol for MODBUS
No
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
No
Width
220 mm
Height
270 mm
Depth
120 mm

Dimensions

2190DIM-33

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.