T3-1-8200/V/SVB-SW 004882 EATON MOELLER Main switch, 1 pole, 32 A, Emergency stop function, 90 °, Lockable i.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

T3-1-8200/V/SVB-SW 004882 EATON MOELLER Main switch, 1 pole, 32 A, Emergency stop function, 90 °, Lockable i..

T3-1-8200/V/SVB-SW

004882

EATON-MOELLER

Available Ship on today

Main switch, 1 pole, 32 A, STOP function, 90 °, Lockable in the 0 (Off) position, rear mounting

More details


* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $48.72
Unit price: $48.72

Quantity Price
1+$48.72
4+$44.75
8+$43.39
11+$42.88
15+$42.47
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Delivery program
Product range
Main switch
maintenance switch
Repair switch
Part group reference
T3
Stop Function
STOP function
With black rotary handle and locking ring
Number of poles
1 pole
Locking facility
Lockable in the 0 (Off) position
Degree of Protection
Front IP65
Design
rear mounting
Contact sequence
Switching angle
° 90
Function
Motor rating AC-23A, 50 - 60 Hz
400 V
PkW 15
Rated uninterrupted current
IuA 32
Note on rated uninterrupted current !u
Rated uninterrupted current Iu is specified for max. cross-section.
Number of contact units
contact unit(s) 1
Technical data
General
Standards
IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL
Switch-disconnector according to IEC/EN 60947-3
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature
Open
°C -25 - +50
Enclosed
°C -25 - +40
Overvoltage category/pollution degree
III/3
Rated impulse withstand voltage
UimpV AC 6000
Mechanical shock resistance
g 15
Mounting position
As required
Contacts
Mechanical variables
Number of poles
1 pole
Electrical characteristics
Rated operational voltage
UeV AC 690
Rated uninterrupted current
IuA 32
Note on rated uninterrupted current !u
Rated uninterrupted current Iu is specified for max. cross-section.
Load rating with intermittent operation, class 12
AB 25 % DF
x Ie 2
AB 40 % DF
x Ie 1.6
AB 60 % DF
x Ie 1.3
Short-circuit rating
Fuse
A gG/gL 35
Rated short-time withstand current (1 s current)
IcwArms 650
Note on rated short-time withstand current lcw
Current for a time of 1 second
Rated conditional short-circuit current
IqkA 1
Switching capacity
cos ϕ rated making capacity as per IEC 60947-3
A 320
Rated breaking capacity cos ϕ to IEC 60947-3
A
230 V
A 260
400/415 V
A 260
500 V
A 240
690 V
A 170
Safe isolation to EN 61140
between the contacts
V AC 440
Current heat loss per contact at Ie
W 1.1
Current heat loss per auxiliary circuit at Ie (AC-15/230 V)
CO 1.1
Lifespan, mechanical
Operationsx 106 > 0.5
Maximum operating frequency
Operations/h 1200
AC
AC-3
Rating, motor load switch
PkW
220 V 230 V
PkW 5.5
230 V Star-delta
PkW 7.5
400 V 415 V
PkW 11
400 V Star-delta
PkW 15
500 V
PkW 15
500 V Star-delta
PkW 18.5
690 V
PkW 11
690 V Star-delta
PkW 22
Rated operational current motor load switch
230 V
IeA 23.7
230 V star-delta
IeA 32
400V 415 V
IeA 23.7
400 V star-delta
IeA 32
500 V
IeA 23.7
500 V star-delta
IeA 32
690 V
IeA 14.7
690 V star-delta
IeA 25.5
AC-21A
Rated operational current switch
440 V
IeA 32
AC-23A
Motor rating AC-23A, 50 - 60 Hz
PkW
230 V
PkW 7.5
400 V 415 V
PkW 15
500 V
PkW 15
690 V
PkW 15
Rated operational current motor load switch
230 V
IeA 32
400 V 415 V
IeA 32
500 V
IeA 26.4
690 V
IeA 17
DC
DC-1, Load-break switches L/R = 1 ms
Rated operational current
IeA 25
Voltage per contact pair in series
V 60
DC-21A
IeA
Rated operational current
IeA 1
Contacts
Quantity 1
DC-23A, motor load switchL/R = 15 ms
24 V
Rated operational current
IeA 25
Contacts
Quantity 1
48 V
Rated operational current
IeA 25
Contacts
Quantity 2
60 V
Rated operational current
IeA 25
Contacts
Quantity 3
120 V
Rated operational current
IeA 12
Contacts
Quantity 3
240 V
Rated operational current
IeA 5
Contacts
Quantity 5
DC-13, Control switches L/R = 50 ms
Rated operational current
IeA 20
Voltage per contact pair in series
V 24
Control circuit reliability at 24 V DC, 10 mA
Fault probabilityHF < 10 -5, < 1 fault in 100000 operations
Terminal capacities
Solid or stranded
mm2 1 x (1 - 6)
2 x (1 - 6)
Flexible with ferrules to DIN 46228
mm2 1 x (0.75 - 4)
2 x (0.75 - 4)
Terminal screw
M4
Tightening torque for terminal screw
Nm 1.6
Technical safety parameters:
Notes
B10d values as per EN ISO 13849-1, table C1
Rating data for approved types
Contacts
Rated operational voltage
UeV AC 600
Rated uninterrupted current max.
Main conducting paths
General use
A 25
Auxiliary contacts
General Use
IUA 10
Pilot Duty
A 600
P 600
Switching capacity
Maximum motor rating
Single-phase
120 V AC
HP 1.5
200 V AC
HP 3
240 V AC
HP 3
Three-phase
200 V AC
HP 3
240 V AC
HP 3
480 V AC
HP 7.5
600 V AC
HP 10
Short Circuit Current Rating
SCCR
Basic Rating
kA 5
max. Fuse
A 40
High fault rating
kA 10
max. Fuse
A 40, Class J
Terminal capacity
Solid or flexible conductor with ferrule
AWG 14 - 10
Terminal screw
M4
Tightening torque
lb-in 17.7
Approvals
Product Standards UL 60947-4-1;CSA - C22.2 No. 60947-4-1-14; CSA-C22.2 No. 94; IEC/EN 60947-3; CE marking
UL File No. E36332
UL Category Control No. NLRV
CSA File No. 12528
CSA Class No. 3211-05
North America Certification UL listed, CSA certified
Specially designed for North America Yes, with an alternative front plate and/or terminal markings to those of the IEC type in combination with "+NA" (105864)
Suitable for Branch circuits, suitable as motor disconnect
Degree of Protection IEC: IP65; UL/CSA Type 1, 12
Technical data ETIM 7.0(Show features)(Hide features)
Low-voltage industrial components (EG000017) / Switch disconnector (EC000216)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Off-load switch, circuit breaker, control switch / Switch disconnector ([email protected] [AKF060013])
Version as main switch
Yes
Version as maintenance-/service switch
Yes
Version as safety switch
No
Version as emergency stop installation
No
Version as reversing switch
No
Number of switches
1
Max. rated operation voltage Ue AC
V 690
Rated operating voltage
V 690 - 690
Rated permanent current Iu
A 32
Rated permanent current at AC-23, 400 V
A 32
Rated permanent current at AC-21, 400 V
A 32
Rated operation power at AC-3, 400 V
kW 11
Rated short-time withstand current lcw
kA 0.65
Rated operation power at AC-23, 400 V
kW 15
Switching power at 400 V
kW 15
Conditioned rated short-circuit current Iq
kA 1
Number of poles
1
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Motor drive optional
No
Motor drive integrated
No
Voltage release optional
No
Device construction
Built-in device fixed built-in technique
Suitable for ground mounting
Yes
Suitable for front mounting 4-hole
No
Suitable for front mounting centre
No
Suitable for distribution board installation
No
Suitable for intermediate mounting
Yes
Colour control element
Black
Type of control element
Door coupling rotary drive
Interlockable
Yes
Type of electrical connection of main circuit
Screw connection
Degree of protection (IP), front side
IP65
Degree of protection (NEMA)
12

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Últimas Opiniones de Nuestros Clientes

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.