LSM-11S/F 292374 LSM-11S-F EATON ELECTRIC Safety position switch, 1N/O+1N/C, rounded plunger, front mount View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

LSM-11S/F 292374 LSM-11S-F EATON ELECTRIC Safety position switch, 1N/O+1N/C, rounded plunger, front mount

LSM-11S/F

292374

LSM-11S-F

EATON-MOELLER

Safety position switch, 1N/O+1N/C, rounded plunger, front mount

LSM-11S/F

More details


Sensors > End switch

Position Switches

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $49.80
Unit price: $49.80

Quantity Price
1+$49.80
2+$48.70
4+$41.45
5+$39.74
7+$38.19
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Safety position switch, 1N/O+1N/C, rounded plunger, front mount
Safety position switch, Basic function: Position switches, Safety position switches, Part group reference: LS(M)-…, Product range: Rounded plunger, Degree of Protection: IP66, IP67, Features: Basic device, not expandable, Ambient temperature: -25 - +70 °C, Contacts N/O = Normally open: 1 N/O, Contacts N/C = Normally closed: 1 NC, Notes: = safety function, by positive opening to IEC/EN 60947-5-1, Positive opening (ZW): yes, Colour Enclosure covers: Yellow, Housing: Metal, Connection type: Cage Clamp, Cage-Clamp is a registered trademark of Wago Kontakttechnik, 32432 Minden, Germany., Accessories for the Cage-Clamp terminals from Wago:power comb, gray, Wago Article No. 264-402, Standards: IEC/EN 60947

Delivery program

Basic function
Position switches
Safety position switches
Part group reference
LS(M)-…
Product range
Rounded plunger
Degree of Protection
IP66, IP67
Features
Basic device, not expandable
Ambient temperature
-25 - +70 °C
Snap-action contact
Yes
Contacts
N/O = Normally open
1 N/O
N/C = Normally closed
1 NC
Notes
= safety function, by positive opening to IEC/EN 60947-5-1
Contact sequence
131S001
Contact travel■ = Contact closed□ = Contact open
131U148
Positive opening (ZW)
yes
Colour
Enclosure covers
Yellow
Enclosure covers
116C064
Housing
Metal
Connection type
Cage Clamp
Notes
Cage-Clamp is a registered trademark of Wago Kontakttechnik, 32432 Minden, Germany.
Accessories for the Cage-Clamp terminals from Wago:power comb, gray, Wago Article No. 264-402

Technical data

General
Standards
IEC/EN 60947
Climatic proofing
Damp heat, constant, to IEC 60068-2-78; damp heat, cyclical, to IEC 60068-2-30
Ambient temperature
-25 - +70 °C
Mounting position
As required
Degree of Protection
IP66, IP67
Terminal capacitiesSolid
1 x (0.5 - 2.5) mm2
Terminal capacitiesFlexible with ferrule
1 x (0.5 - 1.5) mm2
Repetition accuracy
0.15 mm
Contacts/switching capacity
Rated impulse withstand voltage [Uimp]
4000 V AC
Rated insulation voltage [Ui]
400 V
Overvoltage category/pollution degree
III/3
Rated operational current [Ie]AC-1524 V [Ie]
6 A
Rated operational current [Ie]AC-15220 V 230 V 240 V [Ie]
6 A
Rated operational current [Ie]AC-15380 V 400 V 415 V [Ie]
4 A
Rated operational current [Ie]DC-1324 V [Ie]
3 A
Rated operational current [Ie]DC-13110 V [Ie]
0.6 A
Rated operational current [Ie]DC-13220 V [Ie]
0.3 A
Control circuit reliabilityat 24 V DC/5 mA [HF]
< 10-7, < 1 fault in 107operations Fault probability
Control circuit reliabilityat 5 V DC/1 mA [HF]
< 5 x 10-6, < 1 failure at 5 x 106operations Fault probability
Supply frequency
max. 400 Hz
Short-circuit rating to IEC/EN 60947-5-1max. fuse
6 A gG/gL
Rated conditional short-circuit current
1 kA
Mechanical variables
Lifespan, mechanical [Operations]
8 x 106
Contact temperature of roller head
≦ 100 °C
Mechanical shock resistance (half-sinusoidal shock, 20 ms)Standard-action contact
25 g
Operating frequency [Operations/h]
≦ 6000
Actuation
MechanicalActuating force at beginning/end of stroke
1.0/8.0 N
MechanicalActuating torque of rotary drives
0.2 Nm
MechanicalMax. operating speed with DIN cam
1/0.5 m/s
MechanicalNotes
for angle of actuation α = 0°/30°

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
6 A
Heat dissipation per pole, current-dependent [Pvid]
0.17 W
Equipment heat dissipation, current-dependent [Pvid]
0 W
Static heat dissipation, non-current-dependent [Pvs]
0 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+70 °C
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 7.0

Sensors (EG000026) / End switch (EC000030)
Electric engineering, automation, process control engineering / Binary sensor technology, safety-related sensor technology / Position switch / Position switch (Type 1) ([email protected] [AGZ382015])
Width sensor
31 mm
Diameter sensor
0 mm
Height of sensor
61 mm
Length of sensor
33.5 mm
Rated operation current Ie at AC-15, 24 V
6 A
Rated operation current Ie at AC-15, 125 V
6 A
Rated operation current Ie at AC-15, 230 V
6 A
Rated operation current Ie at DC-13, 24 V
3 A
Rated operation current Ie at DC-13, 125 V
0.8 A
Rated operation current Ie at DC-13, 230 V
0.3 A
Switching function
Quick-break switch
Switching function latching
No
Output electronic
No
Forced opening
Yes
Number of safety auxiliary contacts
0
Number of contacts as normally closed contact
1
Number of contacts as normally open contact
1
Number of contacts as change-over contact
0
Type of interface
None
Type of interface for safety communication
None
Construction type housing
Cuboid
Material housing
Metal
Coating housing
Other
Type of control element
Plunger
Alignment of the control element
Other
Type of electric connection
Cable entry metrical
With status indication
No
Suitable for safety functions
Yes
Explosion safety category for gas
None
Explosion safety category for dust
None
Ambient temperature during operating
25 - 70 °C
Degree of protection (IP)
IP67
Degree of protection (NEMA)
4X

Approvals

Product Standards
IEC/EN 60947-5; UL 508; CSA-C22.2 No. 14; CE marking
UL File No.
E29184
UL Category Control No.
NKCR
CSA File No.
12528
CSA Class No.
3211-03
North America Certification
UL listed, CSA certified
Degree of Protection
IEC: IP66, 67, UL/CSA Type 3R, 4X (indoor use only), 12, 13

Dimensions

1310DIM-1
1310DIM-2
① screw-in depth max. 12 mm

Datasheet - PDF

Title: Size: Type:
LSM-11S/F LSM-11S-F 292374 EN_292374.pdf 280 Kbytes   LSM-11S/F LSM-11S-F 292374 EN_292374.pdf

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.