CI-K4-PKZ4-G 225524 0004355164 EATON ELECTRIC Insulated enclosure for PKZ4, +rotary handle, black/grey View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

CI-K4-PKZ4-G 225524 0004355164 EATON ELECTRIC Insulated enclosure for PKZ4, +rotary handle, black/grey

CI-K4-PKZ4-G

225524

0004355164

EATON-MOELLER

Insulated enclosure for PKZ4, +rotary handle, black/grey

CI-K4-PKZ4-G

More details


Low-voltage industrial components > Empty enclosure for switchgear

Motor-protective circuit-breakers PKZ (Accessories)

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $44.71
Unit price: $44.71

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Often bought together

More info



Insulated enclosure for PKZ4, +rotary handle, black/grey
Insulated enclosure for PKZM4, degree of protection IP65, metric cable entry knockout: at top and bottom: M25/M32 in the back plate: M25/M32 control cable entry: M20 incl. insulated PE-terminal, with black-grey rotary knob

General specifications
Product name
Eaton Moeller® series CI-K Accessory Insulated enclosure
Part no.
CI-K4-PKZ4-G
EAN
4015082255244
Product Length/Depth
240 millimetre
Product height
220 millimetre
Product width
160 millimetre
Product weight
1.732 kilogram
Compliances
CE
Product Tradename
CI-K
Product Type
Accessory
Product Sub Type
Insulated enclosure
Features & Functions
Enclosure material
Plastic
Fitted with:
Black-gray rotary knob
Insulated PE(N) terminal
Knockouts
1 x M20 (cable entry knockout for cable entry glands at the top)
1 x M20 (cable entry knockout for cable entry glands at the bottom)
2 x M25/M32 (cable entry knockouts at the rear)
2 x M25/32 (cable entry knockout at the bottom)
Hard mirror with cable entry knockouts (can be cut out)
2 x M25/32 (cable entry knockout at the top)
General information
Degree of protection
IP65
NEMA Other
Model
Surface mounting
Product category
Accessories
Climatic environmental conditions
Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
70 °C
Design verification
Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
29.5 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Please enquire
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 9.0

Low-voltage industrial components (EG000017) / Empty enclosure for switchgear (EC000712)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Component for low-voltage switching technology / Empty housing for switch devices (ecl@ss13-27-37-13-01 [AKN343019])
Housing material
Plastic
Width
160 mm
Height
220 mm
Depth
240 mm
With transparent cover
No
Suitable for emergency stop
No
Model
Surface mounting
Degree of protection (IP)
IP65
Degree of protection (NEMA)
Other

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.