Switch-disconnector-fuse, 3 pole, 40 A, rear mounting, Pillar, NH000/NH00

QSA40N0-00/3+P

Eaton QSA Fuse switch-disconnector, 3 pole, rear mounting, 40 A, Pillar, NH000/NH00

Fuse switch-disconnector QSA40N0-00/3, with terminals, ‌frame size 0 suitable for DIN fuse-links (blade contacts type).

More details


Low-voltage industrial components > Fuse switch disconnector

DUMECO Switch-Disconnectors

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $280.52
Unit price: $280.52

Quantity Price
1+$280.52
2+$252.46
3+$241.03
4+$234.57
5+$233.61
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



General specifications

Product Name
Eaton QSA Fuse switch-disconnector
Catalog Number
1320205
Model Code
QSA40N0-00/3+P
EAN
8711426950467
Product Length/Depth
138 mm
Product Height
138 mm
Product Width
165 mm
Product Weight
1.1 kg
Certifications
CE
IEC/EN 60204
IEC/EN 60947
VDE 0660
IEC/EN 60947-3
RoHS

Features & Functions

Features
Version as main switch
Fitted with:
Connectors
Functions
Optional Stop Function
Number of poles
Four-pole

General

Accessories
Auxiliary contact or neutral conductor fitted by user.
Actuator type
Without actuator
Construction size
NH000, NH00
Degree of protection
IP00
IP20, with terminal cover
Degree of protection (front side)
IP00
Mounting method
Rear mounting
Mounting position
As required
Overvoltage category
III
Pollution degree
3
Product category
Rated impulse withstand voltage (Uimp)
6000 V
Suitable for
Ground mounting
DIN fuse-links (blade contacts type)

Climatic environmental conditions

Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
55 °C
Ambient storage temperature - min
-30 °C
Ambient storage temperature - max
80 °C
Operating temperature - min
-25 °C
Operating temperature - max
55 °C

Electrical rating

Rated insulation voltage (Ui)
690 V
Rated operating voltage (Ue) at AC - max
690 V
Rated operational power at AC-23A, 400 V, 50 Hz
22 kW
Rated short-time withstand current (Icw)
0 kA
Rated uninterrupted current (Iu)
40 A
Uninterrupted current
Rated uninterrupted current Iu is specified for max. cross-section.

Contacts

Number of auxiliary contacts (normally closed contacts)
0
Number of auxiliary contacts (normally open contacts)
0

Design verification

Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
1.5 W
Rated operational current for specified heat dissipation (In)
40 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 1320205 Low-voltage industrial controls and switchgear (EC001040)
Feature Name Feature Value
Version as main switch (EF006981) Yes
Version as safety switch (EF006985) No
Max. rated operation voltage Ue AC (EF007355) 690 V
Rated permanent current Iu (EF001389) 40 A
Rated operation power at AC-23, 400 V (EF007027) 22 kW
Conditioned rated short-circuit current Iq (EF001444) 50 kA
Rated short-time withstand current lcw (EF007050) 0 kA
Suitable for fuses (EF006692) NH000, NH00
Number of poles (EF001391) 4
With error protection (EF007384) No
Type of electrical connection of main circuit (EF006819) Bolt connection
Cable entry (EF000537) Above/under
Equipped with connectors (EF011696) Yes
Suitable for floor mounting (EF007243) Yes
Suitable for front mounting (EF007246) No
Suitable for busbar mounting (EF007259) No
Type of control element (EF006976) Without actuator
Position control element (EF009410) Front
Motor drive optional (EF007386) No
Motor drive integrated (EF006697) No
Version as emergency stop installation (EF006959) No
Degree of protection (IP), front side (EF003118) IP00

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.