FIM-40/4/0,3-A 278515 EATON MOELLER RCD/MCB combination switch, 40A, 0.3A-LS_Char, 4p, A-FI_Char View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

FIM-40/4/0,3-A 278515 EATON MOELLER RCD/MCB combination switch, 40A, 0.3A-LS_Char, 4p, A-FI_Char

FIM-40/4/0,3-A

278515

EATON - MOELLER

Available Ship on today

RCD/MCB combination switch, 40A, 0.3A-LS_Char, 4p, A-FI_Char

More details


Circuit Breakers Electrical Power

To FAZ - EATON - MOELLER

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON - MOELLER

*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Delivery programme
Product range
  FIM
Basic function
  Residual-current protective modules
Rated fault current
IΔNmA300
Rated uninterrupted current
IuA40
Application
  Rated fault current IΔN = 300 mA
Rated current
InA40
Pole
  4 pole
Contact sequence
  
Electrical
Standards
  IEC/EN 61009
Rated operational voltage
UeV 
 
UeV AC230/400
Mechanical
Standard front dimension
 mm45
Enclosure height
 mm90
Terminal protection
  Protection against electric shock to IEC 536
Mounting
  Permanent screw connection with FAZ
Terminals top and bottom
  Lift terminals
 
   
Thickness of busbar material
 mm0.8 … 2
Design verification as per IEC/EN 61439(Show features)(Hide features)
Technical data for design verification
   
Rated operational current for specified heat dissipation
InA40
Heat dissipation per pole, current-dependent
PvidW0
Equipment heat dissipation, current-dependent
PvidW8.4
Static heat dissipation, non-current-dependent
PvsW0
Heat dissipation capacity
PdissW0
Operating ambient temperature min.
 °C-25
Operating ambient temperature max.
 °C40
 
  0
Technical data ETIM 6.0(Show features)(Hide features)
Circuit breakers and fuses (EG000020) / Residual current circuit breaker (RCCB) module (EC002297)
Electric engineering, automation, process control engineering / Electrical installation, device / Residual current protection system / Residual current circuit breaker (RCCB) module ([email protected] [ACN357008])
Nominal voltage
 V230 - 400
Nominal current
 A40
Rated fault current adjustable
  No
Rated fault current
 A0.3 - 0.3
Max. delay time
 ms0
Delay adjustable
  No
Number of poles
  4
Leakage current type
  A
Dimensions
AWA1220-1759 FAZ-FIM combination
 
>>

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Últimas Opiniones de Nuestros Clientes

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.