EU6E-SWD-4DX 174735 EATON ELECTRIC SWD Block module I/O module IP69K, 4 inputs with 24 V DC power supply, 4 .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

EU6E-SWD-4DX 174735 EATON ELECTRIC SWD Block module I/O module IP69K, 4 inputs with 24 V DC power supply, 4 ..

EU6E-SWD-4DX

174735

EATON-MOELLER

SWD Block module I/O module IP69K, 4 inputs with 24 V DC power supply, 4 M12 I/O sockets

More details


PLC's > Fieldbus, decentr. periphery - digital I/O module

Smartwire Darwin

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



SWD Block module I/O module IP69K, 4 inputs with 24 V DC power supply, 4 M12 I/O sockets
SWD module with IP69K degree of protection for connecting 4 digital inputs, sensor supply for each M12 socket: 24 VDC, 70 mA, short-circuit proof, automatic address setting, I/O connection with one M12 socket

Delivery program

Product range
SmartWire-DT slave
Basic function
Digital modules
Function
For connection of digital I/O signals
Inputs
Digital
4
Connection to SmartWire-DT
yes

Technical data

General
Standards
IEC/EN 61131-2
Dimensions (W x H x D)
60 x 157 x 34 mm
Weight
0.25 kg
Mounting
Screw fixing (M4)
Mounting position
As required
24 V DC supply for output supply
Power supplyPower loss [P]
1.5 W
Climatic environmental conditions
Climatic proofing
Dry heat to IEC 60068-2-2
Damp heat as per EN 60068-2-3
Air pressure (operation)
795 - 1080 hPa
Ambient temperatureOperation [ϑ]
-25 - +55 °C
Ambient temperatureStorage / Transport [ϑ]
-40 - +70 °C
Relative humidityCondensation
permissible
Relative humidityRelative humidity, non-condensing (IEC/EN 60068-2-30)
5 - 95 %
Ambient conditions, mechanical
Protection type (IEC/EN 60529, EN50178, VBG 4)
IP69K
Vibrations (IEC/EN 61131-2:2008)Constant amplitude 3,5 mm
5 - 8.4 Hz
Vibrations (IEC/EN 61131-2:2008)Constant acceleration 1 g
8.4 - 150 Hz
Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 30 g/11 ms
9 Impacts
Drop to IEC/EN 60068-2-31 [Drop height]
50 mm
Free fall, packaged (IEC/EN 60068-2-32)
0.3 m
Electromagnetic compatibility (EMC)
Overvoltage category
II
Pollution degree
3
Electrostatic discharge (IEC/EN 61131-2:2008)Air discharge (Level 3)
8 kV
Electrostatic discharge (IEC/EN 61131-2:2008)Contact discharge (Level 2)
4 kV
Electromagnetic fields (IEC/EN 61131-2:2008)80 - 1000 MHz
10 V/m
Electromagnetic fields (IEC/EN 61131-2:2008)1.4 - 2 GHz
3 V/m
Electromagnetic fields (IEC/EN 61131-2:2008)2 - 2.7 GHz
1 V/m
Radio interference suppression (SmartWire-DT)
EN 55011 Class A
Burst (IEC/EN 61131-2:2008, Level 3)Supply cable
2 kV
Burst (IEC/EN 61131-2:2008, Level 3)Signal lines
1 kV
Burst (IEC/EN 61131-2:2008, Level 3)SmartWire-DT cables
1 kV
Surge (IEC/EN 61131-2:2008, Level 1)Surge power cables
0.5 kV
Surge (IEC/EN 61131-2:2008, Level 1)Surge I/O cables
1 kV
Radiated RFI (IEC/EN 61131-2:2008, Level 3)
10 V
SmartWire-DT network
Station type
SmartWire-DT slave
Setting the baud rate
automatic
Baud rate (data transfer speed)
maximum2000 kbps
Status SmartWire-DT
Green LED
SWD-IN
M12 plug (A-keyed), 5 pole
SWD-OUT
M12 socket (A-keyed), 5 pole
Current consumption (24V, without sensor and without I/O supply)Current consumption (24 V SWD supply)
66 mA
Sensor supplyMax. current consumption per M12 I/O plug
70 mA
Sensor supplyOverload and short-circuit proof
yes, with diagnostics
Connection supply and I/O
Terminal for I/O sensorConnection type
5-pin M12 socket (A-keyed)
Digital inputs
Quantity
4
Input current
Normally 4 at 24 V DC mA
Limit value type 1
Low < 5V DC;High > 15V DC
Input delay
High->Low < 0.2 ms
Low->High < 0.2 ms
Status display inputs
yellow LED
Potential isolation
Inputs for SmartWire-DT
No
Input to input
No

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
0 A
Heat dissipation per pole, current-dependent [Pvid]
0 W
Equipment heat dissipation, current-dependent [Pvid]
0 W
Static heat dissipation, non-current-dependent [Pvs]
1.5 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+55 °C
Degree of Protection
IP69K
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Meets the product standard's requirements.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 7.0

PLC's (EG000024) / Fieldbus, decentr. periphery - digital I/O module (EC001599)
Electric engineering, automation, process control engineering / Control / Field bus, decentralized peripheral / Field bus, decentralized peripheral - digital I/O module ([email protected] [BAA055014])
Supply voltage AC 50 Hz
0 - 0 V
Supply voltage AC 60 Hz
0 - 0 V
Supply voltage DC
20.4 - 28.8 V
Voltage type of supply voltage
DC
Number of digital inputs
4
Number of digital outputs
0
Digital inputs configurable
No
Digital outputs configurable
No
Input current at signal 1
4 mA
Permitted voltage at input
20.4 - 28.8 V
Type of voltage (input voltage)
DC
Type of digital output
Other
Output current
0 A
Permitted voltage at output
20.4 - 28.8 V
Type of output voltage
DC
Short-circuit protection, outputs available
No
Number of HW-interfaces industrial Ethernet
0
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces parallel
0
Number of HW-interfaces Wireless
0
Number of HW-interfaces USB
0
Number of HW-interfaces other
0
With optical interface
No
Supporting protocol for TCP/IP
No
Supporting protocol for PROFIBUS
No
Supporting protocol for CAN
No
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for KNX
No
Supporting protocol for MODBUS
No
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
Yes
Radio standard Bluetooth
No
Radio standard WLAN 802.11
No
Radio standard GPRS
No
Radio standard GSM
No
Radio standard UMTS
No
IO link master
No
System accessory
Yes
Degree of protection (IP)
IP69K
Type of electric connection
Screw connection
Time delay at signal exchange
0.2 - 0.2 ms
Fieldbus connection over separate bus coupler possible
Yes
Rail mounting possible
No
Wall mounting/direct mounting
Yes
Front build in possible
No
Rack-assembly possible
No
Suitable for safety functions
No
Category according to EN 954-1
None
SIL according to IEC 61508
None
Performance level acc. EN ISO 13849-1
None
Appendant operation agent (Ex ia)
No
Appendant operation agent (Ex ib)
No
Explosion safety category for gas
None
Explosion safety category for dust
None
Width
60.8 mm
Height
156.8 mm
Depth
34 mm

Approvals

North America Certification
UL listed, CSA certified
Specially designed for North America
No

Dimensions

2723DIM-56
SmartWire-DT I/O modules, EU6E-SWD-… block module
2723DRW-316
① SmartWire-DT connection SWD IN
② SmartWire-DT connection SWD OUT
③ SmartWire-DT diagnostics LED
④ I/O connection X1...X4
⑤ I/O status indicators

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.