ZW7-125 004991 XTOT125C3S EATON ELECTRIC Current transformer-operated overload relay, 85-125A, 1N/O+1N/C View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

ZW7-125 004991 XTOT125C3S EATON ELECTRIC Current transformer-operated overload relay, 85-125A, 1N/O+1N/C

ZW7-125

004991

XTOT125C3S

EATON-MOELLER

Current transformer-operated overload relay, 85-125A, 1N/O+1N/C

More details


Low-voltage industrial components > Thermal overload relay

Thermal Relays

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $426.32
Unit price: $426.32

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



EL-Nummer (Norway)
4131708
Current transformer-operated overload relay, 85-125A, 1N/O+1N/C
Current transformer-operated overload relay, Product range: ZW7 current transformer-operated overload relays, Description: Test/off button, Reset pushbutton manual/auto, Trip-free release, Protection with heavy starting duty, Mounting type: Separate mounting, Auxiliary contacts N/O = Normally open: 1 N/O, Auxiliary contacts N/C = Normally closed: 1 N/C, Standards: IEC/EN 60947, VDE 0660, UL, CSA, Degree of Protection: IP00

Delivery program

Product range
ZW7 current transformer-operated overload relays
Description
Test/off button
Reset pushbutton manual/auto
Trip-free release
Protection with heavy starting duty
Mounting type
Separate mounting
Setting range
Overload releases[Ir]
85 - 125 A
Contact sequence
230S006
Auxiliary contacts
N/O = Normally open
1 N/O
N/C = Normally closed
1 N/C
Notes

The main current parameters are defined by the main current wiring which is used.

Technical data

General
Standards
IEC/EN 60947, VDE 0660, UL, CSA
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperatureOpen
-25 - +50 °C
Ambient temperatureEnclosed
- 25 - 40 °C
Temperature compensation
Continuous
Mounting position
As required
Weight
0.8 kg
Mechanical shock resistance
10
Sinusoidal
Shock duration 10 ms g
Degree of Protection
IP00
Protection against direct contact when actuated from front (EN 50274)
Finger and back-of-hand proof
Altitude
Max. 2000 m
Main conducting paths
Rated impulse withstand voltage [Uimp]
8000 V AC
Overvoltage category/pollution degree
III/3
Rated insulation voltage [Ui]
1000 V
Rated operational voltage [Ue]
1000 V AC
Safe isolation to EN 61140Between auxiliary contacts and main contacts
440 V AC
Safe isolation to EN 61140Between main circuits
440 V AC
Short-circuit protection Maximum fuse
With overload relay in conjunction with a transformer as required for the contactor
Current heat loss (3 conductors)Lower value of the setting range
3 W
Current heat loss (3 conductors)Maximum setting
10 W
Push-through opening [⌀]
27 mm
Auxiliary and control circuits
Rated impulse withstand voltage [Uimp]
4000 V
Overvoltage category/pollution degree
III/3
Terminal capacitiesSolid
1 x (0.75 - 4)
2 x (0.75 - 4) mm2
Terminal capacitiesFlexible with ferrule
1 x (0.75 - 2.5)
2 x (0.75 - 2.5) mm2
Terminal capacitiesSolid or stranded
2 x (18 - 14) AWG
Terminal screw
M3.5
Tightening torque
1.2 Nm
Stripping length
8 mm
ToolsPozidriv screwdriver
2 Size
ToolsStandard screwdriver
1 x 6 mm
Rated insulation voltage [Ui]
500 V AC
Rated operational voltage [Ue]
500 V AC
Safe isolation to EN 61140between the auxiliary contacts
240 V AC
Conventional thermal current [Ith]
6 A
Rated operational current [Ie]AC-15Make contact120 V [Ie]
1.5 A
Rated operational current [Ie]AC-15Make contact220 V 230 V 240 V [Ie]
1.5 A
Rated operational current [Ie]AC-15Make contact380 V 400 V 415 V [Ie]
0.5 A
Rated operational current [Ie]AC-15Make contact500 V [Ie]
0.5 A
Rated operational current [Ie]AC-15Break contact120 V [Ie]
1.5 A
Rated operational current [Ie]AC-15Break contact220 V 230 V 240 V [Ie]
1.5 A
Rated operational current [Ie]AC-15Break contact380 V 400 V 415 V [Ie]
0.9 A
Rated operational current [Ie]AC-15Break contact500 V [Ie]
0.8 A
Rated operational current [Ie]DC L/R ≦ 15 ms
Switch-on and switch-off conditions based on DC-13, time constant as specified.
Rated operational current [Ie]DC L/R ≦ 15 ms24 V [Ie]
0.9 A
Rated operational current [Ie]DC L/R ≦ 15 ms60 V [Ie]
0.75 A
Rated operational current [Ie]DC L/R ≦ 15 ms110 V [Ie]
0.4 A
Rated operational current [Ie]DC L/R ≦ 15 ms220 V [Ie]
0.2 A
Short-circuit rating without weldingmax. fuse
6 A gG/gL
Notes

Ambient temperature: Operating range to IEC/EN 60947, PTB: -5°C to +50°C

Terminal capacities Main circuits solid and flexible with ferrule: When connecting 2 conductors, only the following combinations are admissible:

Rated operational current: Making and breaking currents to DC-13, time constant as stated

Short-circuit rating: See transparent overlay "Fuses" for time/current characteristics (Please enquire)

Rating data for approved types
Auxiliary contactsPilot DutyAC operated
B300 at opposite polarity
B600 at same polarity
Auxiliary contactsPilot DutyDC operated
R300

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
125 A
Heat dissipation per pole, current-dependent [Pvid]
2.1 W
Equipment heat dissipation, current-dependent [Pvid]
6.3 W
Static heat dissipation, non-current-dependent [Pvs]
0 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+50 °C
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 7.0

Low-voltage industrial components (EG000017) / Thermal overload relay (EC000106)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Overload protection device / Thermal overload relay ([email protected] [AKF075014])
Adjustable current range
85 - 125 A
Max. rated operation voltage Ue
690 V
Mounting method
Separate positioning
Type of electrical connection of main circuit
Screw connection
Number of auxiliary contacts as normally closed contact
1
Number of auxiliary contacts as normally open contact
1
Number of auxiliary contacts as change-over contact
0
Release class
Other
Reset function input
No
Reset function automatic
Yes
Reset function push-button
Yes

Approvals

Product Standards
UL 508; CSA-C22.2 No. 14; IEC/EN 60947-4-1; CE marking
UL File No.
E29184
UL Category Control No.
NKCR
CSA File No.
12528
CSA Class No.
3211-03
North America Certification
UL listed, CSA certified
Specially designed for North America
No
Suitable for
Branch circuits
Max. Voltage Rating
600 V AC
Degree of Protection
IEC: IP00, UL/CSA Type: -

Characteristics

Characteristic curve
230U008
These tripping characteristics are mean values of the spread at 20 °C ambient air temperature in a cold state. Tripping time depends on response current. When the devices are at operational temperature the tripping time of the overload relay reduces to approx. 25 % of the read off value.
Characteristic curve
2300DIA-8

Dimensions

230X032
① Reset/on
230X031
Permissible mounting positions

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.