DILP315/22(220-230V50HZ) 207460 XTCFA315M22F EATON ELECTRIC Contactor, 4p+2N/O+2N/C, 315A/AC1 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

DILP315/22(220-230V50HZ) 207460 XTCFA315M22F EATON ELECTRIC Contactor, 4p+2N/O+2N/C, 315A/AC1

DILP315/22(220-230V50HZ)

207460

XTCFA315M22F

EATON-MOELLER

Contactor, 4p+2N/O+2N/C, 315A/AC1

Contactor, 4 pole, 315 A, 2 N/O, 2 NC, 220 V 50 Hz, 230 V 50 Hz, AC operation, Screw terminals

More details


Low-voltage industrial components > Power contactor, AC switching

Contactors more than 170 A

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Contactor, 4 pole, 315 A, 2 N/O, 2 NC, 220 V 50 Hz, 230 V 50 Hz, AC operation, Screw terminals
Contactor, Application: Contactors for 4 pole electric consumers, Contactors larger than 200 A, 4 pole, Utilization category: AC-1: Non-inductive or slightly inductive loads, resistance furnaces, Connection technique: Screw terminals, Number of poles: 4 pole, Rated operational current AC-1 Conventional free air thermal current, 3 pole, 50 - 60 Hz Open at 40 °C: Ith =Ie= 315 A, Rated operational current AC-1 Conventional free air thermal current, 1 pole open: Ith= 880 A, Rated operational current AC-1 220 V 230 V: P= 59 kW, 380 V 400 V: P= 110 kW, 660 V 690 V: P= 160 kW, Contacts N/O = Normally open: 2 N/O, Contacts N/C = Normally closed: 2 NC, Voltage AC/DC: AC operation

Delivery program

Product range
Contactors
Application
Contactors for 4 pole electric consumers
Subrange
Contactors larger than 200 A, 4 pole
Utilization category
AC-1: Non-inductive or slightly inductive loads, resistance furnaces
Connection technique
Screw terminals
Number of poles
4 pole
Rated operational current
AC-1Conventional free air thermal current, 3 pole, 50 - 60 HzOpenat 40 °C [Ith=Ie]
315 A
AC-1Conventional free air thermal current, 3 pole, 50 - 60 HzOpenat 55 °C [Ith=Ie]
270 A
AC-1Conventional free air thermal current, 3 pole, 50 - 60 HzOpenat 60 °C [Ith=Ie]
215 A
AC-1Conventional free air thermal current, 1 poleopen [Ith]
880 A
Contacts
N/O = Normally open
2 N/O
N/C = Normally closed
2 NC
Contact sequence
210S245
For use with
DILP800-XHI…
Actuating voltage
220 V 50 Hz
230 V 50 Hz
Voltage AC/DC
AC operation

Technical data

General
Standards
IEC/EN 60947, VDE 0660
Lifespan, mechanicalAC operated [Operations]
10 x 106
Operating frequency, mechanicalAC operated [Operations/h]
3600
Climatic proofing
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperatureOpen
-40 - +70 °C
Mounting positionMounting position
1210DRW-107
Mechanical shock resistance (IEC/EN 60068-2-27)Half-sinusoidal shock, 15 msMain contactsN/O contact
10 g
Degree of Protection
IP00
Protection against direct contact when actuated from front (EN 50274)
Finger and back-of-hand proof with terminal shroud
Terminal capacity main cableSolid
35 - 120 mm2
Terminal capacity main cableStranded
35 - 120 mm2
Terminal capacity control circuit cablesSolid
2 x (0.5 - 2.5) mm2
Main cable connection screw/bolt
M10
Tightening torque
12 - 16 Nm
Control circuit cable connection screw/bolt
M3.5
Tightening torque
1.2 Nm
ToolControl circuit cablesPozidriv screwdriver
2 Size
Main conducting paths
Rated impulse withstand voltage [Uimp]
8000 V AC
Overvoltage category/pollution degree
III/3
Rated insulation voltage [Ui]
1000 V AC
Rated operational voltage [Ue]
1000 V AC
Safe isolation to EN 61140between coil and contacts
1000 V AC
Safe isolation to EN 61140between the contacts
690 V AC
Making capacity (cos ϕ) [Up to 690 V]
2300
According to IEC/EN 60947 A
Breaking capacity220 V 230 V
2000 A
Breaking capacity380 V 400 V
2000 A
Breaking capacity500 V
1700 A
Breaking capacity660 V 690 V
1700 A
Short-circuit ratingShort-circuit protection maximum fuseType “2” coordination400 V [gG/gL 500 V]
315 A
Short-circuit ratingShort-circuit protection maximum fuseType “1” coordination400 V [gG/gL 500 V]
355 A
AC
AC-1Rated operational currentConventional free air thermal current, 3 pole, 50 - 60 HzOpenat 40 °C [Ith=Ie]
315 A
AC-1Rated operational currentConventional free air thermal current, 3 pole, 50 - 60 HzOpenat 55 °C [Ith=Ie]
270 A
AC-1Rated operational currentConventional free air thermal current, 3 pole, 50 - 60 HzOpenat 60 °C [Ith=Ie]
215 A
AC-1Rated operational currentConventional free air thermal current, 1 poleopen [Ith]
880 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz220 V 230 V [Ie]
210 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz240 V [Ie]
210 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz415 V [Ie]
210 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz440V [Ie]
210 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz500 V [Ie]
210 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz660 V 690 V [Ie]
210 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz1000 V [Ie]
113 A
AC-3Motor rating [P]220 V 230 V [P]
59 kW
AC-3Motor rating [P]240V [P]
59 kW
AC-3Motor rating [P]380 V 400 V [P]
110 kW
AC-3Motor rating [P]415 V [P]
110 kW
AC-3Motor rating [P]440 V [P]
110 kW
AC-3Motor rating [P]660 V 690 V [P]
160 kW
AC-3Motor rating [P]1000 V [P]
160 kW
DC
Rated operational current, openDC-160 V [Ie]
300 A
Rated operational current, openDC-1110 V [Ie]
300 A
Rated operational current, openDC-1220 V [Ie]
300 A
Rated operational current, openDC-1440 V [Ie]
260 A
Rated operational current, openDC-360 V [Ie]
210 A
Rated operational current, openDC-3110 V [Ie]
210 A
Rated operational current, openDC-3220 V [Ie]
210 A
Rated operational current, openDC-3440 V [Ie]
170 A
Rated operational current, openDC-560 V [Ie]
210 A
Rated operational current, openDC-5110 V [Ie]
210 A
Rated operational current, openDC-5220 V [Ie]
210 A
Rated operational current, openDC-5440 V [Ie]
170 A
Current heat loss
4 pole, at Ith
65 W
Magnet systems
Voltage toleranceAC operated [Pick-up]Min. pick-up voltage, AC operated
0.85 x Uc
Voltage toleranceAC operated [Pick-up]Pick-up voltage AC operated, max.
1.1 x Uc
Power consumption of the coil in a cold state and 1.0 x USDual-frequency coil 50/60 Hz [Pick-up]
1100 VA
Power consumption of the coil in a cold state and 1.0 x USDual-frequency coil 60 Hz [Sealing]
65 VA
Power consumption of the coil in a cold state and 1.0 x USDual-frequency coil 50/60 Hz [Sealing]
22 W
Duty factor
100 % DF
Changeover time at 100 % US(recommended value)Main contactsAC operatedClosing delaySwitching times of main contacts AC operated Closing delay, min.
20 ms
Changeover time at 100 % US(recommended value)Main contactsAC operatedClosing delaySwitching times of main contacts AC operated Closing delay, max.
40 ms
Changeover time at 100 % US(recommended value)Main contactsAC operatedOpening delaySwitching times of main contacts AC operated Opening delay, min.
7 ms
Changeover time at 100 % US(recommended value)Main contactsAC operatedOpening delaySwitching times of main contacts AC operated Opening delay, max.
15 ms

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
315 A
Heat dissipation per pole, current-dependent [Pvid]
16.25 W
Equipment heat dissipation, current-dependent [Pvid]
0 W
Static heat dissipation, non-current-dependent [Pvs]
22 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-40 °C
Operating ambient temperature max.
+70 °C
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 7.0

Low-voltage industrial components (EG000017) / Power contactor, AC switching (EC000066)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Contactor (LV) / Power contactor, AC switching ([email protected] [AAB718015])
Rated control supply voltage Us at AC 50HZ
220 - 230 V
Rated control supply voltage Us at AC 60HZ
0 - 0 V
Rated control supply voltage Us at DC
0 - 0 V
Voltage type for actuating
AC
Rated operation current Ie at AC-1, 400 V
315 A
Rated operation current Ie at AC-3, 400 V
210 A
Rated operation power at AC-3, 400 V
110 kW
Rated operation current Ie at AC-4, 400 V
0 A
Rated operation power at AC-4, 400 V
0 kW
Rated operation power NEMA
0 kW
Modular version
No
Number of auxiliary contacts as normally open contact
2
Number of auxiliary contacts as normally closed contact
2
Type of electrical connection of main circuit
Rail connection
Number of normally closed contacts as main contact
0
Number of main contacts as normally open contact
4

Approvals

Product Standards
IEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking
UL File No.
E29096
UL Category Control No.
NLDX
CSA File No.
LR72236
North America Certification
UL listed, CSA certified
Specially designed for North America
No

Characteristics

Characteristic curve
210U038
Switching conditions for 4 pole, non-motor loads
Operating characteristics
Non inductive and slightly inductive loads
Electrical characteristics
Switch on: 1 x rated operational current
Switch off: 1 x rated operational current
Utilization category
100 % AC-1
Typical examples of application
Electric heat

Dimensions

210X099
① DILP800-XHI-SI
② DILP800-XHI11-SA
DILP315 + DILP315-XHB

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.