DILM400/22(RA110) 208208 XTCE400M22Y EATON ELECTRIC Contactor, 3p+2N/O+2N/C, 200kW/400V/AC3 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

DILM400/22(RA110) 208208 XTCE400M22Y EATON ELECTRIC Contactor, 3p+2N/O+2N/C, 200kW/400V/AC3

DILM400/22(RA110)

208208

XTCE400M22Y

EATON-MOELLER

Contactor, 3p+2N/O+2N/C, 200kW/400V/AC3

DILM400/22(RA110)

Contactor, 380 V 400 V 212 kW, 2 N/O, 2 NC, RA 110: 48 - 110 V 40 - 60 Hz/48 - 110 V DC, AC and DC operation, Screw connection

More details


Low-voltage industrial components > Power contactor, AC switching

Contactors more than 170 A

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $2,869.51
Unit price: $2,869.51

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



EL-Nummer (Norway)
4110229
Contactor, 380 V 400 V 212 kW, 2 N/O, 2 NC, RA 110: 48 - 110 V 40 - 60 Hz/48 - 110 V DC, AC and DC operation, Screw connection
Contactor, Application: Contactors for Motors, Comfort devices greater than 170 A, Utilization category: AC-1: Non-inductive or slightly inductive loads, resistance furnaces, NAC-3: Normal AC induction motors: starting, switch off during running, AC-4: Normal AC induction motors: starting, plugging, reversing, inching, Connection technique: Screw connection, Rated operational current AC-3 380 V 400 V: Ie= 400 A, Rated operational current AC-1 Conventional free air thermal current, 3 pole, 50 - 60 Hz Open at 40 °C: Ith =Ie= 612 A, enclosed: Ith= 450 A, Rated operational current AC-1 Conventional free air thermal current, 1 pole open: Ith= 1250 A, enclosed: Ith= 1125 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 125 kW, 380 V 400 V: P= 212 kW, 660 V 690 V: P= 300 kW, Max. rating for three-phase motors, 50 - 60 Hz AC-4 220 V 230 V: P= 92 kW, 380 V 400 V: P= 160 kW, 660 V 690 V: P= 240 kW, Can be combined with auxiliary contact: DILM820-XHI…, Contacts N/O = Normally open: 2 N/O, Contacts N/C = Normally closed: 2 NC, Instructions: integrated suppressor circuit in actuating electronics, 660 V, 690 V or 1000 V: not directly reversing, Voltage AC/DC: AC and DC operation

Delivery program

Product range
Contactors
Application
Contactors for Motors
Subrange
Comfort devices greater than 170 A
Utilization category
AC-1: Non-inductive or slightly inductive loads, resistance furnaces
NAC-3: Normal AC induction motors: starting, switch off during running
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
Connection technique
Screw connection
Rated operational current
AC-3380 V 400 V [Ie]
400 A
AC-1Conventional free air thermal current, 3 pole, 50 - 60 HzOpenat 40 °C [Ith=Ie]
612 A
AC-1Conventional free air thermal current, 3 pole, 50 - 60 Hzenclosed [Ith]
450 A
AC-1Conventional free air thermal current, 1 poleopen [Ith]
1250 A
AC-1Conventional free air thermal current, 1 poleenclosed [Ith]
1125 A
Max. rating for three-phase motors, 50 - 60 Hz
AC-3220 V 230 V [P]
125 kW
AC-3380 V 400 V [P]
212 kW
AC-3660 V 690 V [P]
300 kW
AC-31000 V [P]
132 kW
AC-4220 V 230 V [P]
92 kW
AC-4380 V 400 V [P]
160 kW
AC-4660 V 690 V [P]
240 kW
AC-41000 V [P]
132 kW
Contact sequence
210S058
Can be combined with auxiliary contact
DILM820-XHI…
Actuating voltage
RA 110: 48 - 110 V 40 - 60 Hz/48 - 110 V DC
Voltage AC/DC
AC and DC operation
Contacts
N/O = Normally open
2 N/O
N/C = Normally closed
2 NC
Auxiliary contacts
possible variants at auxiliary contact module fitting options
on the side: 2 x DILM820-XHI11(V)-SI; 2 x DILM820-XHI11-SA
Side mounting auxiliary contacts
2100DRW-97
Instructions
Interlocked opposing contacts according to IEC/EN 60947-5-1 Appendix L, inside the auxiliary contact module
Auxiliary contacts used as mirror contacts according to IEC/EN 60947-4-1 Appendix F (not N/C late open)
Instructions
integrated suppressor circuit in actuating electronics
660 V, 690 V or 1000 V: not directly reversing

Technical data

General
Standards
IEC/EN 60947, VDE 0660, UL, CSA
Lifespan, mechanicalAC operated [Operations]
7 x 106
Lifespan, mechanicalDC operated [Operations]
7 x 106
Operating frequency, mechanicalAC operated [Operations/h]
2000
Operating frequency, mechanicalDC operated [Operations/h]
2000
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperatureOpen
-40 - +60 °C
Ambient temperatureEnclosed
- 40 - + 40 °C
Ambient temperatureStorage
- 40 - + 80 °C
Mounting position
210N017210N018
Mechanical shock resistance (IEC/EN 60068-2-27)Half-sinusoidal shock, 10 msMain contactsN/O contact
10 g
Mechanical shock resistance (IEC/EN 60068-2-27)Half-sinusoidal shock, 10 msAuxiliary contactsN/O contact
10 g
Mechanical shock resistance (IEC/EN 60068-2-27)Half-sinusoidal shock, 10 msAuxiliary contactsN/C contact
8 g
Degree of Protection
IP00
Protection against direct contact when actuated from front (EN 50274)
Finger and back-of-hand proof with terminal shroud or terminal block
Altitude
Max. 2000 m
WeightAC operated
8.55 kg
WeightDC operated
8.55 kg
WeightWeight
8.55 kg
Terminal capacity main cableFlexible with cable lug
50 - 240 mm2
Terminal capacity main cableStranded with cable lug
70 - 240 mm2
Terminal capacity main cableSolid or stranded
2/0 - 500 MCM AWG
Terminal capacity main cableFlat conductor [Lamellenzahl x Breite x Dicke ]
Fixing with flat cable terminal or cable terminal blocks
See terminal capacity for cable terminal blocks mm
Terminal capacity main cableBusbar [Width]
25 mm
Main cable connection screw/bolt
M10
Tightening torque
24 Nm
Terminal capacity control circuit cablesSolid
1 x (0.75 - 2.5)
2 x (0.75 - 2.5) mm2
Terminal capacity control circuit cablesFlexible with ferrule
1 x (0.75 - 2.5)
2 x (0.75 - 2.5) mm2
Terminal capacity control circuit cablesSolid or stranded
18 - 14 AWG
Control circuit cable connection screw/bolt
M3.5
Tightening torque
1.2 Nm
ToolMain cableWidth across flats
16 mm
ToolControl circuit cablesPozidriv screwdriver
2 Size
Main conducting paths
Rated impulse withstand voltage [Uimp]
8000 V AC
Overvoltage category/pollution degree
III/3
Rated insulation voltage [Ui]
1000 V AC
Rated operational voltage [Ue]
1000 V AC
Safe isolation to EN 61140between coil and contacts
500 V AC
Safe isolation to EN 61140between the contacts
500 V AC
Making capacity (p.f. to IEC/EN 60947)
5500 A
Breaking capacity220 V 230 V
5000 A
Breaking capacity380 V 400 V
5000 A
Breaking capacity500 V
5000 A
Breaking capacity660 V 690 V
5000 A
Breaking capacity1000 V
950 A
Component lifespan
AC1: See → Engineering, characteristic curves
AC3: See → Engineering, characteristic curves
AC4: See → Engineering, characteristic curves
Short-circuit ratingShort-circuit protection maximum fuseType “2” coordination400 V [gG/gL 500 V]
500 A
Short-circuit ratingShort-circuit protection maximum fuseType “2” coordination690 V [gG/gL 690 V]
500 A
Short-circuit ratingShort-circuit protection maximum fuseType “2” coordination1000 V [gG/gL 1000 V]
200 A
Short-circuit ratingShort-circuit protection maximum fuseType “1” coordination400 V [gG/gL 500 V]
630 A
Short-circuit ratingShort-circuit protection maximum fuseType “1” coordination690 V [gG/gL 690 V]
630 A
Short-circuit ratingShort-circuit protection maximum fuseType “1” coordination1000 V [gG/gL 1000 V]
250 A
AC
AC-1Rated operational currentConventional free air thermal current, 3 pole, 50 - 60 HzOpenat 40 °C [Ith=Ie]
612 A
AC-1Rated operational currentConventional free air thermal current, 3 pole, 50 - 60 HzOpenat 50 °C [Ith=Ie]
548 A
AC-1Rated operational currentConventional free air thermal current, 3 pole, 50 - 60 HzOpenat 55 °C [Ith=Ie]
522 A
AC-1Rated operational currentConventional free air thermal current, 3 pole, 50 - 60 HzOpenat 60 °C [Ith=Ie]
500 A
AC-1Rated operational currentConventional free air thermal current, 3 pole, 50 - 60 Hzenclosed [Ith]
450 A
AC-1Rated operational currentConventional free air thermal current, 3 pole, 50 - 60 HzNotes
At maximum permissible ambient air temperature.
AC-1Rated operational currentConventional free air thermal current, 1 poleNote
at maximum permissible ambient air temperature
AC-1Rated operational currentConventional free air thermal current, 1 poleopen [Ith]
1250 A
AC-1Rated operational currentConventional free air thermal current, 1 poleenclosed [Ith]
1125 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 HzNotes
At maximum permissible ambient temperature (open.)
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz220 V 230 V [Ie]
400 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz240 V [Ie]
400 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz380 V 400 V [Ie]
400 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz415 V [Ie]
400 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz440V [Ie]
400 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz500 V [Ie]
400 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz660 V 690 V [Ie]
325 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz1000 V [Ie]
95 A
AC-3Motor rating [P]220 V 230 V [P]
125 kW
AC-3Motor rating [P]240V [P]
132 kW
AC-3Motor rating [P]380 V 400 V [P]
212 kW
AC-3Motor rating [P]415 V [P]
232 kW
AC-3Motor rating [P]440 V [P]
250 kW
AC-3Motor rating [P]500 V [P]
280 kW
AC-3Motor rating [P]660 V 690 V [P]
300 kW
AC-3Motor rating [P]1000 V [P]
132 kW
AC-4Rated operational currentOpen, 3-pole: 50 – 60 Hz220 V 230 V [Ie]
296 A
AC-4Rated operational currentOpen, 3-pole: 50 – 60 Hz240 V [Ie]
296 A
AC-4Rated operational currentOpen, 3-pole: 50 – 60 Hz380 V 400 V [Ie]
296 A
AC-4Rated operational currentOpen, 3-pole: 50 – 60 Hz415 V [Ie]
296 A
AC-4Rated operational currentOpen, 3-pole: 50 – 60 Hz440 V [Ie]
296 A
AC-4Rated operational currentOpen, 3-pole: 50 – 60 Hz500 V [Ie]
296 A
AC-4Rated operational currentOpen, 3-pole: 50 – 60 Hz660 V 690 V [Ie]
260 A
AC-4Rated operational currentOpen, 3-pole: 50 – 60 Hz1000 V [Ie]
95 A
AC-4Motor rating [P]220 V 230 V [P]
92 kW
AC-4Motor rating [P]240 V [P]
100 kW
AC-4Motor rating [P]380 V 400 V [P]
160 kW
AC-4Motor rating [P]415 V [P]
176 kW
AC-4Motor rating [P]440 V [P]
186 kW
AC-4Motor rating [P]500 V [P]
210 kW
AC-4Motor rating [P]660 V 690 V [P]
240 kW
AC-4Motor rating [P]1000 V [P]
132 kW
Condensor operation
Individual compensation, rated operational current Ieof three-phase capacitorsOpenup to 525 V
307 A
Individual compensation, rated operational current Ieof three-phase capacitorsOpen690 V
177 A
Max. inrush current peak
30 x Ie
Component lifespan [Operations]
0.1 x 106
Max. operating frequency
200 Ops/h
DC
Rated operational current, openDC-1Notes
see DILDC300/DILDC600 or on request
Current heat loss
3 pole, at Ith(60°)
58 W
Current heat loss at Ieto AC-3/400 V
37 W
Impedance per pole
0.077 mΩ
Magnet systems
Voltage toleranceUS
48 - 110 V 40-60 Hz
48 - 110 V DC
Voltage toleranceAC operated [Pick-up]
0.7 x US min- 1.15 x US max
Voltage toleranceDC operated [Pick-up]
0.7 x US min- 1.15 x US max
Voltage toleranceAC operated [Drop-out]
0.2 x US max- 0.6 x US min
Voltage toleranceDC operated [Drop-out]
0.2 x US max- 0.6 x US min
Power consumption of the coil in a cold state and 1.0 x USNote on power consumption
Control transformer with uk≦ 6%
Power consumption of the coil in a cold state and 1.0 x USPull-in power [Pick-up]
450 VA
Power consumption of the coil in a cold state and 1.0 x USPull-in power [Pick-up]
350 W
Power consumption of the coil in a cold state and 1.0 x USSealing power [Sealing]
12.1 VA
Power consumption of the coil in a cold state and 1.0 x USSealing power [Sealing]
6.3 W
Duty factor
100 % DF
Changeover time at 100 % US(recommended value)Main contactsClosing delay
80 ms
Changeover time at 100 % US(recommended value)Main contactsOpening delay
110 ms
Behaviour in marginal and transitional conditionsSealingVoltage interruptions(0 … 0.2 x Uc min) ≦ 10 ms
Time is bridged successfully
Behaviour in marginal and transitional conditionsSealingVoltage interruptions(0 … 0.2 x Uc min) > 10 ms
Drop-out of the contactor
Behaviour in marginal and transitional conditionsSealingVoltage drops(0.2 … 0.6 x Uc min) ≦ 12 ms
Time is bridged successfully
Behaviour in marginal and transitional conditionsSealingVoltage drops(0.2 … 0.6 x Uc min) > 12 ms
Drop-out of the contactor
Behaviour in marginal and transitional conditionsSealingVoltage drops(0.6 … 0.7 x Uc min)
Contactor remains switched on
Behaviour in marginal and transitional conditionsSealingExcess voltage(1.15 … 1.3 x Uc max)
Contactor remains switched on
Behaviour in marginal and transitional conditionsSealingPick-up phase(0 … 0.7 x Uc min)
Contactor does not switch on
Behaviour in marginal and transitional conditionsSealingPick-up phase(0.7 x Uc min… 1.15 x Uc max)
Contactor switches on with certainty
Admissible transitional contact resistance (of the external control circuit device when actuating A11)
≦ 500 mΩ
PLC signal level (A3 - A4) to IEC/EN 61131-2 (type 2)High
15 V
PLC signal level (A3 - A4) to IEC/EN 61131-2 (type 2)Low
5 V
Electromagnetic compatibility (EMC)
Electromagnetic compatibility
This product is designed for operation in industrial environments (environment A). Its use in residential environments (environment B) may cause radio-frequency interference, requiring additional noise suppression measures.
Rating data for approved types
Switching capacityMaximum motor ratingThree-phase200 V
208 V
125 HP
Switching capacityMaximum motor ratingThree-phase230 V
240 V
150 HP
Switching capacityMaximum motor ratingThree-phase460 V
480 V
300 HP
Switching capacityMaximum motor ratingThree-phase575 V
600 V
400 HP
Switching capacityGeneral use
450 A
Auxiliary contactsPilot DutyAC operated
A600
Auxiliary contactsPilot DutyDC operated
P300
Auxiliary contactsGeneral UseAC
600 V
Auxiliary contactsGeneral UseAC
15 A
Auxiliary contactsGeneral UseDC
250 V
Auxiliary contactsGeneral UseDC
1 A
Short Circuit Current RatingBasic RatingSCCR
30 kA
Short Circuit Current RatingBasic Ratingmax. Fuse
800 A
Short Circuit Current RatingBasic Ratingmax. CB
600 A
Short Circuit Current Rating480 V High FaultSCCR (fuse)
30/100 kA
Short Circuit Current Rating480 V High Faultmax. Fuse
800/600 Class J A
Short Circuit Current Rating480 V High FaultSCCR (CB)
100 kA
Short Circuit Current Rating480 V High Faultmax. CB
600 A
Short Circuit Current Rating600 V High FaultSCCR (fuse)
30/100 kA
Short Circuit Current Rating600 V High Faultmax. Fuse
800/600 Class J A
Short Circuit Current Rating600 V High FaultSCCR (CB)
30 kA
Short Circuit Current Rating600 V High Faultmax. CB
600 A
Special Purpose RatingsDefinite Purpose Ratings (100,000 cycles acc. to UL 1995)LRA 480V 60Hz 3phase
3300 A
Special Purpose RatingsDefinite Purpose Ratings (100,000 cycles acc. to UL 1995)FLA 480V 60Hz 3phase
550 A
Special Purpose RatingsDefinite Purpose Ratings (100,000 cycles acc. to UL 1995)LRA 600V 60Hz 3phase
3120 A
Special Purpose RatingsDefinite Purpose Ratings (100,000 cycles acc. to UL 1995)FLA 600V 60Hz 3phase
420 A

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
400 A
Heat dissipation per pole, current-dependent [Pvid]
12.33 W
Equipment heat dissipation, current-dependent [Pvid]
0 W
Static heat dissipation, non-current-dependent [Pvs]
6.3 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-40 °C
Operating ambient temperature max.
+60 °C
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 7.0

Low-voltage industrial components (EG000017) / Power contactor, AC switching (EC000066)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Contactor (LV) / Power contactor, AC switching ([email protected] [AAB718015])
Rated control supply voltage Us at AC 50HZ
48 - 110 V
Rated control supply voltage Us at AC 60HZ
48 - 110 V
Rated control supply voltage Us at DC
48 - 110 V
Voltage type for actuating
AC/DC
Rated operation current Ie at AC-1, 400 V
612 A
Rated operation current Ie at AC-3, 400 V
400 A
Rated operation power at AC-3, 400 V
200 kW
Rated operation current Ie at AC-4, 400 V
296 A
Rated operation power at AC-4, 400 V
160 kW
Rated operation power NEMA
223 kW
Modular version
No
Number of auxiliary contacts as normally open contact
2
Number of auxiliary contacts as normally closed contact
2
Type of electrical connection of main circuit
Rail connection
Number of normally closed contacts as main contact
0
Number of main contacts as normally open contact
3

Approvals

Product Standards
IEC/EN 60947-4-1; UL 60947-4-1; CSA - C22.2 No. 60947-4-1-14; CE marking
UL File No.
E29096
UL Category Control No.
NLDX
CSA File No.
012528
CSA Class No.
3211-04
North America Certification
UL listed, CSA certified
Specially designed for North America
No

Characteristics

Side mounting auxiliary contacts
2100DRW-97
possible variants at auxiliary contact module fitting options
on the side: 2 x DILM820-XHI11(V)-SI; 2 x DILM820-XHI11-SA
Characteristic curve
210U035
Normal switching duty
Normal AC induction motor
Operating characteristics
Switch on: from stop
Switch off: during run
Electrical characteristics:
Switch on: up to 6 x Rated motor current
Switch off: up to 1 x Rated motor current
Utility category
100 % AC-3
Typical Applications
Compressors
Lifts
Mixers
Pumps
Escalators
Agitators
fan
Conveyor belts
Centrifuges
Hinged flaps
Bucket-elevator
Air-conditioning systems
General drives for manufacturing and processing machines
Characteristic curve
210U037
Extreme switching duty
Squirrel-cage motor
Operating characteristics
Inching, plugging, reversing
Electrical characteristics
Make: up to 6 x rated motor current
Break: up to 6 x rated motor current
Utilization category
100 % AC-4
Typical applications
Printing presses
Wire-drawing machines
Centrifuges
Special drives for manufacturing and processing machines
Characteristic curve
210U038
Switching conditions for 3 pole, non-motor loads
Operating characteristics
Non inductive and slightly inductive loads
Electrical characteristics
Switch on: 1 x rated operational current
Switch off: 1 x rated operational current
Utilization category
100 % AC-1
Typical examples of application
Electric heat
Characteristic curve
210U040
Short-time loading, 3-pole
Time interval between two loading cycles: 15 minutes

Dimensions

210X094
① DILM820-XHI11(V)-SI
② DILM820-XHI11-SA

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.