AC-1Rated operational currentConventional free air thermal current, 3 pole, 50 - 60 HzOpenat 40 °C [Ith=Ie]
45 A
AC-1Rated operational currentConventional free air thermal current, 3 pole, 50 - 60 HzOpenat 50 °C [Ith=Ie]
43 A
AC-1Rated operational currentConventional free air thermal current, 3 pole, 50 - 60 HzOpenat 60 °C [Ith=Ie]
40 A
AC-1Rated operational currentConventional free air thermal current, 3 pole, 50 - 60 Hzenclosed [Ith]
36 A
AC-1Rated operational currentConventional free air thermal current, 1 poleopen [Ith]
100 A
AC-1Rated operational currentConventional free air thermal current, 1 poleenclosed [Ith]
90 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 HzNotes
At maximum permissible ambient temperature (open.)
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz220 V 230 V [Ie]
25 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz240 V [Ie]
25 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz380 V 400 V [Ie]
25 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz415 V [Ie]
25 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz440V [Ie]
25 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz500 V [Ie]
25 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz660 V 690 V [Ie]
15 A
AC-3Motor rating [P]220 V 230 V [P]
7.5 kW
AC-3Motor rating [P]240V [P]
8.5 kW
AC-3Motor rating [P]380 V 400 V [P]
11 kW
AC-3Motor rating [P]415 V [P]
14.5 kW
AC-3Motor rating [P]440 V [P]
15.5 kW
AC-3Motor rating [P]500 V [P]
17.5 kW
AC-3Motor rating [P]660 V 690 V [P]
14 kW
AC-4Open, 3-pole: 50 – 60 Hz220 V 230 V [Ie]
13 A
AC-4Open, 3-pole: 50 – 60 Hz240 V [Ie]
13 A
AC-4Open, 3-pole: 50 – 60 Hz380 V 400 V [Ie]
13 A
AC-4Open, 3-pole: 50 – 60 Hz415 V [Ie]
13 A
AC-4Open, 3-pole: 50 – 60 Hz440 V [Ie]
13 A
AC-4Open, 3-pole: 50 – 60 Hz500 V [Ie]
13 A
AC-4Open, 3-pole: 50 – 60 Hz660 V 690 V [Ie]
10 A
AC-4Motor rating [P]220 V 230 V [P]
3.5 kW
AC-4Motor rating [P]240 V [P]
4 kW
AC-4Motor rating [P]380 V 400 V [P]
6 kW
AC-4Motor rating [P]415 V [P]
6.5 kW
AC-4Motor rating [P]440 V [P]
7 kW
AC-4Motor rating [P]500 V [P]
8 kW
AC-4Motor rating [P]660 V 690 V [P]
8.5 kW
3 pole, at Ith(60°)
9.6 W
Current heat loss at Ieto AC-3/400 V
4.2 W
Voltage toleranceAC operated [Pick-up]
0.8 - 1.15 x Uc
Voltage toleranceDrop-out voltage AC operated [Drop-out]
0.2 - 0.5 x Uc
Power consumption of the coil in a cold state and 1.0 x USElectronic actuation [Pick-up]
14 VA
Power consumption of the coil in a cold state and 1.0 x USElectronic actuation [Sealing]
0.7 VA
Power consumption of the coil in a cold state and 1.0 x USElectronic actuation [Sealing]
0.8 W
Operating timesClosing delay
40 ms
Operating timesOpening delay
45 ms
-suitable according to
SEMI F47
Electromagnetic compatibility (EMC)
Emitted interference
according to EN 60947-1
Interference immunity
according to EN 60947-1
Additional technical data
like the contactar [DIL]
M25
Rating data for approved types
Switching capacityMaximum motor ratingThree-phase200 V
208 V
7.5 HP
Switching capacityMaximum motor ratingThree-phase230 V
240 V
10 HP
Switching capacityMaximum motor ratingThree-phase460 V
480 V
15 HP
Switching capacityMaximum motor ratingThree-phase575 V
600 V
20 HP
Switching capacityMaximum motor ratingSingle-phase115 V
120 V
2 HP
Switching capacityMaximum motor ratingSingle-phase230 V
240 V
5 HP
Switching capacityGeneral use
40 A
Auxiliary contactsPilot DutyAC operated
A600
Auxiliary contactsPilot DutyDC operated
P300
Auxiliary contactsGeneral UseAC
600 V
Auxiliary contactsGeneral UseAC
10 A
Auxiliary contactsGeneral UseDC
250 V
Auxiliary contactsGeneral UseDC
1 A
Short Circuit Current RatingBasic RatingSCCR
5 kA
Short Circuit Current RatingBasic Ratingmax. Fuse
125 A
Short Circuit Current RatingBasic Ratingmax. CB
125 A
Short Circuit Current Rating480 V High FaultSCCR (fuse)
10/100 kA
Short Circuit Current Rating480 V High Faultmax. Fuse
125/70 Class J A
Short Circuit Current Rating480 V High FaultSCCR (CB)
10/65 kA
Short Circuit Current Rating480 V High Faultmax. CB
50/32 A
Short Circuit Current Rating600 V High FaultSCCR (fuse)
10/100 kA
Short Circuit Current Rating600 V High Faultmax. Fuse
125/100 Class J A
Short Circuit Current Rating600 V High FaultSCCR (CB)
10/22 kA
Short Circuit Current Rating600 V High Faultmax. CB
50/32 A
Special Purpose RatingsElectrical Discharge Lamps (Ballast)480V 60Hz 3phase, 277V 60Hz 1phase
40 A
Special Purpose RatingsElectrical Discharge Lamps (Ballast)600V 60Hz 3phase, 347V 60Hz 1phase
40 A
Special Purpose RatingsIncandescent Lamps (Tungsten)480V 60Hz 3phase, 277V 60Hz 1phase
40 A
Special Purpose RatingsIncandescent Lamps (Tungsten)600V 60Hz 3phase, 347V 60Hz 1phase
40 A
Special Purpose RatingsResistance Air Heating480V 60Hz 3phase, 277V 60Hz 1phase
40 A
Special Purpose RatingsResistance Air Heating600V 60Hz 3phase, 347V 60Hz 1phase
40 A
Special Purpose RatingsRefrigeration Control (CSA only)LRA 480V 60Hz 3phase
240 A
Special Purpose RatingsRefrigeration Control (CSA only)FLA 480V 60Hz 3phase
40 A
Special Purpose RatingsRefrigeration Control (CSA only)LRA 600V 60Hz 3phase
180 A
Special Purpose RatingsRefrigeration Control (CSA only)FLA 600V 60Hz 3phase
30 A
Special Purpose RatingsDefinite Purpose Ratings (100,000 cycles acc. to UL 1995)LRA 480V 60Hz 3phase
150 A
Special Purpose RatingsDefinite Purpose Ratings (100,000 cycles acc. to UL 1995)FLA 480V 60Hz 3phase
25 A
Special Purpose RatingsElevator Control200V 60Hz 3phase
3 HP
Special Purpose RatingsElevator Control200V 60Hz 3phase
11 A
Special Purpose RatingsElevator Control240V 60Hz 3phase
5 HP
Special Purpose RatingsElevator Control240V 60Hz 3phase
15.2 A
Special Purpose RatingsElevator Control480V 60Hz 3phase
10 HP
Special Purpose RatingsElevator Control480V 60Hz 3phase
14 A
Special Purpose RatingsElevator Control600V 60Hz 3phase
15 HP
Special Purpose RatingsElevator Control600V 60Hz 3phase
17 A