DILMC17-01(230V50HZ,240V60HZ) 277611 EATON MOELLER Contactor, 3p+1N/C, 7.5kW/400V/AC3 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

DILMC17-01(230V50HZ,240V60HZ) 277611 EATON MOELLER Contactor, 3p+1N/C, 7.5kW/400V/AC3

DILMC17-01(230V50HZ,240V60HZ)

277611

EATON - MOELLER

Available

Ship on today

Contactor, 3p+1N/C, 7.5kW/400V/AC3

More details


Contactor Relays

DIL Contactors - EATON - MOELLER

DIL Contactors up to 170A - EATON - MOELLER

* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

QuantityPrice
1+28,43 €
4+26,63 €
8+25,98 €
12+25,65 €
16+25,46 €
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Delivery programme
Product range
  Contactors
Application
  Contactors for Motors
Subrange
  Contactors up to 170 A, 3 pole
Utilization category
  AC-1: Non-inductive or slightly inductive loads, resistance furnaces
NAC-3: Normal AC induction motors: starting, switch off during running
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
 
  >
Notes
  Also suitable for motors with efficiency class IE3.
IE3-ready devices are identified by the logo on their packaging.
Connection technique
  Spring-loaded terminals
Description
  Spring-cage terminals on auxiliary and control circuit terminals
Pole
  3 pole
Rated operational current
   
AC-3
   
380 V 400 V
IeA18
AC-1
   
Conventional free air thermal current, 3 pole, 50 - 60 Hz
   
Open
   
at 40 °C
Ith =IeA40
enclosed
IthA32
Conventional free air thermal current, 1 pole
   
open
IthA88
enclosed
IthA80
Max. rating for three-phase motors, 50 - 60 Hz
   
AC-3
   
220 V 230 V
PkW5
380 V 400 V
PkW7.5
660 V 690 V
PkW11
AC-4
   
220 V 230 V
PkW2.5
380 V 400 V
PkW4.5
660 V 690 V
PkW6.5
Contacts
   
N/C = Normally closed
  1 NC
Contact sequence
  >
Instructions
  Contacts to EN 50 012.
Auxiliary current, coil connections with spring-cage connection technology.
Main current connections with screw terminals.
with mirror contact.
Can be combined with auxiliary contact
  DILA-XHIC(V)..
Voltage AC/DC
  AC operation
Technical data
General
Standards
  IEC/EN 60947, VDE 0660, UL, CSA
Lifespan, mechanical
   
AC operated
Operationsx 10610
DC operated
Operationsx 10610
Operating frequency, mechanical
   
AC operated
Operations/h 5000
DC operated
Operations/h 5000
Climatic proofing
  Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature
   
Open
 °C-25 - +60
Enclosed
 °C- 25 - 40
Storage
 °C- 40 - 80
Mounting position
  >>
Mechanical shock resistance (IEC/EN 60068-2-27)
   
Half-sinusoidal shock, 10 ms
   
Main contacts
   
N/O contact
 g10
Auxiliary contacts
   
N/O contact
 g7
N/C contact
 g5
Mechanical shock resistance (IEC/EN 60068-2-27) when tabletop-mounted
   
Half-sinusoidal shock, 10 ms
   
Main contacts
   
N/O contact
 g6.9
Auxiliary contacts
   
N/O contact
 g5.3
N/C contact
 g3.5
Degree of Protection
  IP00
Protection against direct contact when actuated from front (EN 50274)
  Finger and back-of-hand proof
Weight
   
AC operated
 kg0.42
DC operated
 kg0.48
Terminal capacity main cable
   
Solid
 mm21 x (0.75 - 16)
2 x (0.75 - 10)
Flexible with ferrule
 mm21 x (0.75 - 16)
2 x (0.75 - 10)
Stranded
 mm21 x 16
Solid or stranded
 AWG18 - 6
Main cable connection screw/bolt
  M5
Tightening torque
 Nm3.2
Tool
   
Main cable
   
Pozidriv screwdriver
 Size2
Standard screwdriver
 mm0.8 x 5.5
1 x 6
Terminal capacity control circuit cables
   
Solid
 mm21 x (0.75 - 2.5)
2 x (0.75 - 2.5)
Flexible
 mm21 x (0.75 - 2.5)
2 x (0.75 - 2.5)
Flexible with ferrule
 mm21 x (0.75 - 1.5)
2 x (0.75 - 1.5)
Solid or stranded
 AWG18 - 14
Tool
   
Stripping length
 mm10
Screwdriver blade width
 mm3.5
Main conducting paths
Rated impulse withstand voltage
UimpV AC8000
Overvoltage category/pollution degree
  III/3
Rated insulation voltage
UiV AC690
Rated operational voltage
UeV AC690
Safe isolation to EN 61140
   
between coil and contacts
 V AC440
between the contacts
 V AC440
Making capacity (p.f. to IEC/EN 60947)
   
 
Up to 690 VA238
Breaking capacity
   
220 V 230 V
 A170
380 V 400 V
 A170
500 V
 A170
660 V 690 V
 A120
Short-circuit rating
   
Short-circuit protection maximum fuse
   
Type “2” coordination
   
400 V
gG/gL 500 VA35
690 V
gG/gL 690 VA35
Type “1” coordination
   
400 V
gG/gL 500 VA63
690 V
gG/gL 690 VA50
AC
AC-1
   
Rated operational current
   
Conventional free air thermal current, 3 pole, 50 - 60 Hz
   
Open
   
at 40 °C
Ith =IeA40
at 50 °C
Ith =IeA38
at 55 °C
Ith =IeA37
at 60 °C
Ith =IeA35
enclosed
IthA32
Conventional free air thermal current, 1 pole
   
open
IthA88
enclosed
IthA80
AC-3
   
Rated operational current
   
Open, 3-pole: 50 – 60 Hz
   
220 V 230 V
IeA18
240 V
IeA18
380 V 400 V
IeA18
415 V
IeA18
440V
IeA18
500 V
IeA18
660 V 690 V
IeA12
380 V 400 V
IeA18
Motor rating
PkWh 
220 V 230 V
PkW5
240V
PkW5.5
380 V 400 V
PkW7.5
415 V
PkW10
440 V
PkW10.5
500 V
PkW12
660 V 690 V
PkW11
AC-4
   
Open, 3-pole: 50 – 60 Hz
   
220 V 230 V
IeA10
240 V
IeA10
380 V 400 V
IeA10
415 V
IeA10
440 V
IeA10
500 V
IeA10
660 V 690 V
IeA8
Motor rating
PkWh 
220 V 230 V
PkW2.5
240 V
PkW3
380 V 400 V
PkW4.5
415 V
PkW5
440 V
PkW5.5
500 V
PkW6
660 V 690 V
PkW6.5
DC
Rated operational current, open
   
DC-1
   
60 V
IeA35
110 V
IeA35
220 V
IeA35
440 V
IeA2.9
DC-3
   
60 V
IeA35
110 V
IeA35
220 V
IeA10
440 V
IeA0.6
DC-5
   
60 V
IeA35
110 V
IeA35
220 V
IeA10
440 V
IeA0.6
Current heat loss
3-pole at Ith
 W8.7
Current heat loss at Ie to AC-3/400 V
 W2.1
Impedance per pole
 mΩ2.7
Magnet systems
Voltage tolerance
 x Uc 
AC operated
Pick-upx Uc0.8 - 1.1
Drop-out voltage AC operated
Drop-outx Uc0.3 - 0.6
DC operated
Pick-upx Uc0.7 - 1.2
DC operated
Drop-outx Uc0.15 - 0.6
Notes
  at least smoothed two-phase bridge rectifier or three-phase rectifier
Power consumption of the coil in a cold state and 1.0 x Uc
   
50 Hz
Pick-upVA52
50 Hz
SealingVA7.1
50 Hz
SealingW2.1
60 Hz
Pick-upVA67
60 Hz
SealingVA8.7
60 Hz
SealingW2.6
50/60 Hz
Pick-upVA62
58
50/60 Hz
SealingVA9.1
6.5
50/60 Hz
SealingW2.5
2
DC operated
Pick-upW

Datasheet - PDF

Title:Language:Size:Type:
pdf-XTCEC018C01F Contactor, 3p1N/C, 7.5kW/400V/AC3 - EATON - DILMC17-01230V50HZ,240V60HZ - 277611English601 Kbytespdf-XTCEC018C01F Contactor, 3p1N/C, 7.5kW/400V/AC3 - EATON - DILMC17-01230V50HZ,240V60HZ - 277611

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review