DILMF95(RAC240) 104477 XTCE095F00B-F47 EATON ELECTRIC Contactor, 3p, 100HP/600VAC, SEMI F47 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

DILMF95(RAC240) 104477 XTCE095F00B-F47 EATON ELECTRIC Contactor, 3p, 100HP/600VAC, SEMI F47

DILMF95(RAC240)

104477

XTCE095F00B-F47

EATON-MOELLER

Contactor, 3p, 100HP/600VAC, SEMI F47

DILMF95(RAC240)

Contactors for Semiconductor Industries acc. to SEMI F47, 380 V 400 V: 95 A, RAC 240: 190 - 240 V 50/60 Hz, Screw terminals

More details


Low-voltage industrial components > Power contactor, AC switching

Contactors up to 170A

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $405.32
Unit price: $405.32

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Contactors for Semiconductor Industries acc. to SEMI F47, 380 V 400 V: 95 A, RAC 240: 190 - 240 V 50/60 Hz, Screw terminals
Contactor, Application: Contactors for Semiconductor Industries acc. to SEMI F47, Contactors up to 150 A with electronic actuation, Utilization category: AC-1: Non-inductive or slightly inductive loads, resistance furnaces, NAC-3: Normal AC induction motors: starting, switch off during running, AC-4: Normal AC induction motors: starting, plugging, reversing, inching, Connection technique: Screw terminals, Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging., Description: Contactors suitable for semi-conductor industry according to SEMI F47., Contactors hum-free, suitable for building services automation., Operating mechanism adjustable from 50 Hz to 400 Hz., Number of poles: 3 pole, Rated operational current AC-3 380 V 400 V: Ie= 95 A, Rated operational current AC-1 Conventional free air thermal current, 3 pole, 50 - 60 Hz Open at 40 °C: Ith =Ie= 130 A, enclosed: Ith= 100 A, Rated operational current AC-1 Conventional free air thermal current, 1 pole open: Ith= 275 A, enclosed: Ith= 250 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 30 kW, 380 V 400 V: P= 45 kW, 660 V 690 V: P= 75 kW, Max. rating for three-phase motors, 50 - 60 Hz AC-4 220 V 230 V: P= 16 kW, 380 V 400 V: P= 26 kW, 660 V 690 V: P= 35 kW, Instructions: Contacts to EN 50 012., built-in suppressor circuit'

Delivery program

Product range
Contactors
Application
Contactors for Semiconductor Industries acc. to SEMI F47
Subrange
Contactors up to 150 A with electronic actuation
Utilization category
AC-1: Non-inductive or slightly inductive loads, resistance furnaces
NAC-3: Normal AC induction motors: starting, switch off during running
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
0000SPC-571
Notes
Also suitable for motors with efficiency class IE3.
IE3-ready devices are identified by the logo on their packaging.
Connection technique
Screw terminals
Description
Contactors suitable for semi-conductor industry according to SEMI F47.
Contactors hum-free, suitable for building services automation.
Operating mechanism adjustable from 50 Hz to 400 Hz.
Number of poles
3 pole
Rated operational current
AC-3380 V 400 V [Ie]
95 A
AC-1Conventional free air thermal current, 3 pole, 50 - 60 HzOpenat 40 °C [Ith=Ie]
130 A
AC-1Conventional free air thermal current, 3 pole, 50 - 60 Hzenclosed [Ith]
100 A
AC-1Conventional free air thermal current, 1 poleopen [Ith]
275 A
AC-1Conventional free air thermal current, 1 poleenclosed [Ith]
250 A
Max. rating for three-phase motors, 50 - 60 Hz
AC-3220 V 230 V [P]
30 kW
AC-3380 V 400 V [P]
45 kW
AC-3660 V 690 V [P]
75 kW
AC-4220 V 230 V [P]
16 kW
AC-4380 V 400 V [P]
26 kW
AC-4660 V 690 V [P]
35 kW
Contact sequence
210S045
Actuating voltage
RAC 240: 190 - 240 V 50/60 Hz
Instructions
Contacts to EN 50 012.
built-in suppressor circuit'
integrated suppressor circuit in actuating electronics

Technical data

General
Mounting position
210N017210N019
Altitude
Max. 2000 m
AC
AC-1Rated operational currentConventional free air thermal current, 3 pole, 50 - 60 HzOpenat 40 °C [Ith=Ie]
130 A
AC-1Rated operational currentConventional free air thermal current, 3 pole, 50 - 60 HzOpenat 50 °C [Ith=Ie]
125 A
AC-1Rated operational currentConventional free air thermal current, 3 pole, 50 - 60 HzOpenat 60 °C [Ith=Ie]
110 A
AC-1Rated operational currentConventional free air thermal current, 3 pole, 50 - 60 Hzenclosed [Ith]
100 A
AC-1Rated operational currentConventional free air thermal current, 1 poleopen [Ith]
275 A
AC-1Rated operational currentConventional free air thermal current, 1 poleenclosed [Ith]
250 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 HzNotes
At maximum permissible ambient temperature (open.)
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz220 V 230 V [Ie]
95 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz240 V [Ie]
95 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz380 V 400 V [Ie]
95 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz415 V [Ie]
95 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz440V [Ie]
95 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz500 V [Ie]
95 A
AC-3Rated operational currentOpen, 3-pole: 50 – 60 Hz660 V 690 V [Ie]
80 A
AC-3Motor rating [P]220 V 230 V [P]
30 kW
AC-3Motor rating [P]240V [P]
32 kW
AC-3Motor rating [P]380 V 400 V [P]
45 kW
AC-3Motor rating [P]415 V [P]
57 kW
AC-3Motor rating [P]440 V [P]
60 kW
AC-3Motor rating [P]500 V [P]
70 kW
AC-3Motor rating [P]660 V 690 V [P]
75 kW
AC-4Open, 3-pole: 50 – 60 Hz220 V 230 V [Ie]
50 A
AC-4Open, 3-pole: 50 – 60 Hz240 V [Ie]
50 A
AC-4Open, 3-pole: 50 – 60 Hz380 V 400 V [Ie]
50 A
AC-4Open, 3-pole: 50 – 60 Hz415 V [Ie]
50 A
AC-4Open, 3-pole: 50 – 60 Hz440 V [Ie]
50 A
AC-4Open, 3-pole: 50 – 60 Hz500 V [Ie]
50 A
AC-4Open, 3-pole: 50 – 60 Hz660 V 690 V [Ie]
37 A
AC-4Motor rating [P]220 V 230 V [P]
16 kW
AC-4Motor rating [P]240 V [P]
17 kW
AC-4Motor rating [P]380 V 400 V [P]
26 kW
AC-4Motor rating [P]415 V [P]
30 kW
AC-4Motor rating [P]440 V [P]
32 kW
AC-4Motor rating [P]500 V [P]
36 kW
AC-4Motor rating [P]660 V 690 V [P]
35 kW
Current heat loss
3 pole, at Ith(60°)
21.8 W
Current heat loss at Ieto AC-3/400 V
12.6 W
Magnet systems
Voltage toleranceAC operated [Pick-up]
0.8 - 1.15 x Uc
Voltage toleranceDrop-out voltage AC operated [Drop-out]
0.2 - 0.5 x Uc
Power consumption of the coil in a cold state and 1.0 x USElectronic actuation [Pick-up]
75 VA
Power consumption of the coil in a cold state and 1.0 x USElectronic actuation [Sealing]
2 VA
Power consumption of the coil in a cold state and 1.0 x USElectronic actuation [Sealing]
2 W
Duty factor
100 % DF
Operating timesClosing delay
55 ms
Operating timesOpening delay
40 ms
-suitable according to
SEMI F47
Electromagnetic compatibility (EMC)
Emitted interference
according to EN 60947-1
Interference immunity
according to EN 60947-1
Additional technical data
like the contactar [DIL]
M95
Rating data for approved types
Switching capacityMaximum motor ratingThree-phase200 V
208 V
30 HP
Switching capacityMaximum motor ratingThree-phase230 V
240 V
40 HP
Switching capacityMaximum motor ratingThree-phase460 V
480 V
75 HP
Switching capacityMaximum motor ratingThree-phase575 V
600 V
100 HP
Switching capacityMaximum motor ratingSingle-phase115 V
120 V
7.5 HP
Switching capacityMaximum motor ratingSingle-phase230 V
240 V
15 HP
Switching capacityGeneral use
125 A
Short Circuit Current RatingBasic RatingSCCR
10 kA
Short Circuit Current RatingBasic Ratingmax. Fuse
600 A
Short Circuit Current RatingBasic Ratingmax. CB
600 A
Short Circuit Current Rating480 V High FaultSCCR (fuse)
30/100 kA
Short Circuit Current Rating480 V High Faultmax. Fuse
300/300 Class J A
Short Circuit Current Rating480 V High FaultSCCR (CB)
65 kA
Short Circuit Current Rating480 V High Faultmax. CB
250 A
Short Circuit Current Rating600 V High FaultSCCR (fuse)
30/100 kA
Short Circuit Current Rating600 V High Faultmax. Fuse
300/300 Class J A
Short Circuit Current Rating600 V High FaultSCCR (CB)
30 kA
Short Circuit Current Rating600 V High Faultmax. CB
350 A
Special Purpose RatingsElectrical Discharge Lamps (Ballast)480V 60Hz 3phase, 277V 60Hz 1phase
100 A
Special Purpose RatingsElectrical Discharge Lamps (Ballast)600V 60Hz 3phase, 347V 60Hz 1phase
100 A
Special Purpose RatingsIncandescent Lamps (Tungsten)480V 60Hz 3phase, 277V 60Hz 1phase
100 A
Special Purpose RatingsIncandescent Lamps (Tungsten)600V 60Hz 3phase, 347V 60Hz 1phase
100 A
Special Purpose RatingsResistance Air Heating480V 60Hz 3phase, 277V 60Hz 1phase
100 A
Special Purpose RatingsResistance Air Heating600V 60Hz 3phase, 347V 60Hz 1phase
100 A
Special Purpose RatingsRefrigeration Control (CSA only)LRA 480V 60Hz 3phase
540 A
Special Purpose RatingsRefrigeration Control (CSA only)FLA 480V 60Hz 3phase
90 A
Special Purpose RatingsRefrigeration Control (CSA only)LRA 600V 60Hz 3phase
420 A
Special Purpose RatingsRefrigeration Control (CSA only)FLA 600V 60Hz 3phase
70 A
Special Purpose RatingsDefinite Purpose Ratings (100,000 cycles acc. to UL 1995)LRA 480V 60Hz 3phase
570 A
Special Purpose RatingsDefinite Purpose Ratings (100,000 cycles acc. to UL 1995)FLA 480V 60Hz 3phase
95 A
Special Purpose RatingsElevator Control200V 60Hz 3phase
20 HP
Special Purpose RatingsElevator Control200V 60Hz 3phase
62.1 A
Special Purpose RatingsElevator Control240V 60Hz 3phase
30 HP
Special Purpose RatingsElevator Control240V 60Hz 3phase
80 A
Special Purpose RatingsElevator Control480V 60Hz 3phase
60 HP
Special Purpose RatingsElevator Control480V 60Hz 3phase
77 A
Special Purpose RatingsElevator Control600V 60Hz 3phase
75 HP
Special Purpose RatingsElevator Control600V 60Hz 3phase
77 A

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
95 A
Heat dissipation per pole, current-dependent [Pvid]
4.2 W
Equipment heat dissipation, current-dependent [Pvid]
12.6 W
Static heat dissipation, non-current-dependent [Pvs]
0.8 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+60 °C
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 7.0

Low-voltage industrial components (EG000017) / Power contactor, AC switching (EC000066)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Contactor (LV) / Power contactor, AC switching ([email protected] [AAB718015])
Rated control supply voltage Us at AC 50HZ
190 - 240 V
Rated control supply voltage Us at AC 60HZ
190 - 240 V
Rated control supply voltage Us at DC
0 - 0 V
Voltage type for actuating
AC
Rated operation current Ie at AC-1, 400 V
110 A
Rated operation current Ie at AC-3, 400 V
95 A
Rated operation power at AC-3, 400 V
95 kW
Rated operation current Ie at AC-4, 400 V
50 A
Rated operation power at AC-4, 400 V
26 kW
Rated operation power NEMA
55 kW
Modular version
No
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Screw connection
Number of normally closed contacts as main contact
0
Number of main contacts as normally open contact
3

Approvals

Product Standards
IEC/EN 60947-4-1; UL 60947-4-1; CSA - C22.2 No. 60947-4-1-14; CE marking
UL File No.
E29096
UL Category Control No.
NLDX
CSA File No.
012528
CSA Class No.
2411-03, 3211-04
North America Certification
UL listed, CSA certified
Specially designed for North America
No

Characteristics

2100CON-2
Accessories
1: Overload relay
2: Auxiliary contact module
Characteristic curve
210U038
Switching conditions for non-motor consumers, 3 pole, 4 pole
Operating characteristics
Non inductive and slightly inductive loads
Electrical characteristics
Switch on: 1 x rated operational current
Switch off: 1 x rated operational current
Utilization category
100 % AC-1
Typical examples of application
Electric heat
Characteristic curve
210U039

Dimensions

210X203
Contactor with auxiliary contact module
210T016
distance at side to earthed parts: 10 mm

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.