DSF54CP385 CARLO GAVAZZI Selected parameters MONITORED VARIABLE Surge protection Others SIZE 72 mm POWER SU.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

DSF54CP385 CARLO GAVAZZI Selected parameters MONITORED VARIABLE Surge protection Others SIZE 72 mm POWER SU..

DSF54CP385

CARLO GAVAZZI

Selected parameters MONITORED VARIABLE Surge protection Others SIZE 72 mm POWER SUPPLY RANGE Type 2 MONITORING FUNCTION Protection for AC systems MOUTING DIN-rail INPUT RANGE 385VAC

More details


Inductive Sensors Proximity Switches

Sensors

Inductive Sensors and Loop Detector

* Brand new product in its original packaging covered by the warranties and certifications provided by CARLO GAVAZZI

* This article is obsolete. Please ask us for a quotation and we will check if there are units available or we will offer you an alternative product.

Related products

More info



Monitoring Relays
Surge Arresters forAC systems
Type DSF A/P
• Type 2 (class C) according to EN61643-11 (VDE 0675, part 6-11)
• Approved UL1449 3rd Edition
• Complies with IEC-61643-1, UTE C 61-740-51
• Do not require backup fuse up to 200kArms (UL 1449 3rdEd.)
• Innovative tecnology to prevent dangerous failures in case of temporary overvoltages
• Suitable for unstable networks where sustainend over- voltages may persist for some minutes or longer
• Plug-in cartridges
• Optical indication of exhausted cartridges (red window)
• Voltage-free contact, for remote function monitoring
• Including thermal and dynamic separating device
• Assembled unit ready for mounting
• Marked connections
• For DIN-rail mounting
Product Description Ordering Key
DSF 52 C A 277
DSF A/P are Type 2 (Class C) surge arresters according to EN 61643-11 (VDE 0675, part 6-11) and UL1449 3rd edition suitable for protect- ingAC systemsfromtran- sient overvoltage due to both indirect atmospheric discharges and switching actions.
It is available for both single
and three phase AC lines, TN-S and TN-C.
The control windows (no/red indication) and the contact allow both a local and a remote monitoring of the status of the plug-in car- tridges,warning the opera- tor about the need to promptly replacethecar-
tridges themselves.
These surge protecting devices are Tipe II hence suitable for installation in main distributioncabinet, or secondarydistribution board, in installations with- outexternal LPS (Lightning Protection System) or where thedistance between the LPS elements and the solar panel frames is >50m.
Thesedevicesdonot require any external backup fuse thus saving space and cost.Inaccordingto UL1449 3rd Ed. and UTE C
61-740-51 DSF and canbe
installed on a DIN-rail in any commercially available dis- tribution box.
Description Code
Mounting
DIN-rail D
Function
Surge arrestersS
Type
Type 2 (class C) “Fuseless” F
Cartridge dimensions
17.5 mm5
Configuration
Single pole1
Two poles (2+0)2
Three poles (3+0)3
4 poles (4+0) 4
Contact
None X
1 (relay) C
Network
AC 1 phase A
AC 3 phases P
MCOV (AC)
150 VAC150
300 VAC277
385 VAC385
460 VAC 440
550 VAC 550
750 VAC 750
No backup-fuse tecnology
Long duration overvoltage path
The arrester is activated in the event of electric power system failure. The voltages are much lower than transient voltages
butsubstantially more destructive. The
system is composed of a current limitera
and a varistor. In the event of increased voltage level the current limiter circuit lim- its the current through the varistor. When the normal condition is re-established (rat- ed line voltage), the surge arrester contin- ues to perform its normal function.
Transient(short duration) overvoltage path The arrester is activated at the occurence of instantaneous high voltage surges last- ing only a few microseconds. Such condi-
tion states are experienced at switching
b operations and atmospheric discharges.
The system is composed of a gas tube surge arrester and a varistor. Both compo-
c nents have a very short response time
which is reflected in a low protective resid- ual voltage level. This provides an efficient
d protection of sensitive electronic devices.
a) Current limiterb) Gas tubec) Thermal disconnectord) Varistor
1 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. REV0 100713

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Últimas Opiniones de Nuestros Clientes

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.