GA75-10-00 1SBL411025R8800 ABB GA75-10-00 230-240V 50Hz / 240-260V 60Hz Contactor View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

GA75-10-00 1SBL411025R8800 ABB GA75-10-00 230-240V 50Hz / 240-260V 60Hz Contactor

1SBL411025R8800

ABB

GA75-10-00 230-240V 50Hz / 240-260V 60Hz Contactor

More details


Low-voltage industrial components > Power contactor, DC switching

Contactors and overload relays > Contactors "A" FRCTLP

* Brand new product in its original packaging covered by the warranties and certifications provided by ABB

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



GA75 contactors are designed for DC circuit switching. Arc suppression is more difficult in DC than in AC. To choose a contactor, it is necessary to know the current and voltage to be broken as well as the L/R time constant of the power circuit to be controlled. GA75 contactors are of the block type design. - Main poles: the contactors are fitted with arc chutes with permanent magnets specially designed for DC breaking. The three contactor paths are arranged in series via two supplied and fitted insulated connections (25 mm²). The GA75 are "single-pole" devices for which the connection polarities indicated next to the connection terminals must be respected. Furthermore, they are marked 1L1 for the positive terminal and 2T1 for the negative terminal. - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available

Ordering

  • EAN:
    3471522099884
  • Minimum Order Quantity:
    1 piece
  • Customs Tariff Number:
    85369085

Dimensions

  • Product Net Width:
    70mm
  • Product Net Depth:
    108mm
  • Product Net Height:
    132mm
  • Product Net Weight:
    1.220kg

Container Information

  • Package Level 1 Units:
    1 piece
  • Package Level 1 Width:
    140 mm
  • Package Level 1 Length:
    146 mm
  • Package Level 1 Height:
    96 mm
  • Package Level 1 Gross Weight:
    1.22 kg
  • Package Level 1 EAN:
    3471522099884
  • Package Level 2 Units:
    63 piece

Technical

  • Number of Main Contacts NO:
    1
  • Number of Main Contacts NC:
    0
  • Number of Auxiliary Contacts NO:
    0
  • Number of Auxiliary Contacts NC:
    0
  • Rated Operational Voltage:
    Main Circuit 600 V
  • Conventional Free-air Thermal Current (Ith):
    acc. to IEC 60947-4-1, Open Contactors q = 40 °C 125 A
  • Short-Circuit Protective Devices:
    gG Type Fuses 160 A
  • Rated Short-time Withstand Current (Icw):
    at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 135 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
  • Maximum Electrical Switching Frequency:
    300 cycles per hour
  • Rated Operational Current DC-1 (Ie):
    (440 V) 55 °C 100 A
  • Rated Operational Current DC-3 (Ie):
    (440 V) 85 A
  • Rated Operational Current DC-5 (Ie):
    (220 V) 85 A
    (440 V) 35 A
  • Rated Insulation Voltage (Ui):
    acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
    acc. to UL/CSA 600 V
  • Rated Impulse Withstand Voltage (Uimp):
    8 kV
  • Mechanical Durability:
    10 million
  • Maximum Mechanical Switching Frequency:
    3600 cycles per hour
  • Coil Operating Limits:
    (acc. to IEC 60947-4-1)0.85 ... 1.1 x Uc (at θ ≤ 55 °C) °C
  • Rated Control Circuit Voltage (Uc):
    50 Hz 230 … 240 V
    60 Hz 240 … 260 V
  • Coil Consumption:
    Pull-in at Max. Rated Control Circuit Voltage 50 Hz 180 V·A
    Pull-in at Max. Rated Control Circuit Voltage 60 Hz 210 V·A
    Holding at Max. Rated Control Circuit Voltage 60 Hz 18 V·A
    Holding at Max. Rated Control Circuit Voltage 60 Hz 5.5 W
    Holding at Max. Rated Control Circuit Voltage 50 Hz 18 V·A
    Holding at Max. Rated Control Circuit Voltage 50 Hz 5.5 W
    Average Holding Value 50 / 60 Hz 18 V·A
    Average Holding Value 50 / 60 Hz 5.5 W
    Average Pull-in Value 50 Hz 190 V·A
    Average Pull-in Value 60 Hz 180 V·A
  • Operate Time:
    Between Coil Energization and NO Contact Closing 8 ... 27 ms
    Between Coil De-energization and NO Contact Opening 4 ... 11 ms
  • Connecting Capacity-Main Circuit:
    Flexible with Cable End6 ... 16 mm²
    Rigid Cable6 ... 25 mm²
  • Connecting Capacity-Auxiliary Circuit:
    Flexible with Cable End0.75 ... 2.5 mm²
    Rigid Cable1 ... 4 mm²
  • Degree of Protection:
    acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
  • Connecting terminals (delivered in open position) Main poles:
    M 6 (+,-) pozidriv 2 screws with 1x (13 x 10 mm) connector
  • Terminal Type:
    Screw Terminals

Environmental

  • Ambient Air Temperature:
    Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 °C
    Near Contactor for Operation in Free Air (Uc) -40 ... +70 °C
    Close to Contactor for Storage -60 ... +80 °C
  • Climatic Withstand:
    acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
  • Maximum Operating Altitude Permissible:
    3000 m
  • RoHS Status:
    No declaration needed

Certificates and Declarations (Document Number)

Classifications

  • ETIM 5:
    EC002552 - Power contactor, DC switching
  • UNSPSC:
    39121529

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.