1SFL558029R7811

ABB

CONTACTOR#AM300-30-11#110-125V 50/60Hz / DC

More details


Low-voltage industrial components > Power contactor, AC switching

Contactors and overload relays > Contactors "A" SECRLP

* Brand new product in its original packaging covered by the warranties and certifications provided by ABB

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 690 V. Magnetically latch, control voltage 110-125 V, AC/DC latch

Ordering

  • EAN:
    7320500356920
  • Minimum Order Quantity:
    1 piece
  • Customs Tariff Number:
    85364900

Dimensions

  • Product Net Width:
    164.0mm
  • Product Net Depth:
    180.5mm
  • Product Net Height:
    227.0mm
  • Product Net Weight:
    6.100kg

Container Information

  • Package Level 1 Units:
    1 piece
  • Package Level 1 Width:
    200 mm
  • Package Level 1 Length:
    220 mm
  • Package Level 1 Height:
    280 mm
  • Package Level 1 Gross Weight:
    6.1 kg
  • Package Level 1 EAN:
    7320500356920

Technical

  • Number of Main Contacts NO:
    3
  • Number of Main Contacts NC:
    0
  • Number of Auxiliary Contacts NO:
    1
  • Number of Auxiliary Contacts NC:
    1
  • Rated Operational Voltage:
    Main Circuit 690 V
  • Rated Frequency (f):
    Main Circuit 50/60 Hz
  • Conventional Free-air Thermal Current (Ith):
    acc. to IEC 60947-4-1, Open Contactors q = 40 °C 500 A
  • Rated Operational Current AC-1 (Ie):
    (690 V) 55 °C 400 A
    (690 V) 40 °C 500 A
    (690 V) 70 °C 325 A
  • Rated Operational Current AC-3 (Ie):
    (415 V) 55 °C 300 A
    (690 V) 55 °C 280 A
    (220 / 230 / 240 V) 55 °C 305 A
    (440 V) 55 °C 280 A
    (380 / 400 V) 55 °C 305 A
    (500 V) 55 °C 280 A
  • Rated Operational Power AC-3 (Pe):
    (500 V) 200 kW
    (220 / 230 / 240 V) 90 kW
    (690 V) 250 kW
    (380 / 400 V) 160 kW
    (440 V) 160 kW
    (415 V) 160 kW
  • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:
    8 x Ie AC-3
  • Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
    10 x Ie AC-3
  • Short-Circuit Protective Devices:
    gG Type Fuses 500 A
  • Rated Short-time Withstand Current (Icw):
    at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1500 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2400 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3500 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1100 A
  • Maximum Breaking Capacity:
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3000 A
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2500 A
  • Maximum Electrical Switching Frequency:
    AC-3 300 cycles per hour
    AC-1 300 cycles per hour
    AC-2 / AC-4 150 cycles per hour
  • Rated Operational Current DC-1 (Ie):
    (110 V) 2 Poles in Series, 40 °C 450 A
    (220 V) 3 Poles in Series, 40 °C 450 A
  • Rated Operational Current DC-3 (Ie):
    (110 V) 2 Poles in Series, 40 °C 450 A
    (220 V) 3 Poles in Series, 40 °C 450 A
  • Rated Operational Current DC-5 (Ie):
    (110 V) 2 Poles in Series, 40 °C 450 A
    (220 V) 3 Poles in Series, 40 °C 450 A
  • Rated Insulation Voltage (Ui):
    acc. to UL/CSA 600 V
    acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
  • Rated Impulse Withstand Voltage (Uimp):
    Main Circuit 8 kV
  • Mechanical Durability:
    5 million
  • Maximum Mechanical Switching Frequency:
    300 cycles per hour
  • Coil Operating Limits:
    (acc. to IEC 60947-4-1)0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) °C
  • Rated Control Circuit Voltage (Uc):
    60 Hz 110…125 V
    50 Hz 110…125 V
    DC Operation 110…125 V
  • Coil Consumption:
    Pull-in at Max. Rated Control Circuit Voltage 60 Hz 470 V·A
    Holding at Max. Rated Control Circuit Voltage DC 2 W
    Holding at Max. Rated Control Circuit Voltage 50 Hz 10 V·A
    Pull-in at Max. Rated Control Circuit Voltage DC 520 W
    Pull-in at Max. Rated Control Circuit Voltage 50 Hz 470 V·A
    Holding at Max. Rated Control Circuit Voltage 60 Hz 10 V·A
  • Operate Time:
    Between Coil Energization and NO Contact Closing 50 … 90 ms
    Between Coil De-energization and NO Contact Opening 43 … 53 ms
    Between Coil De-energization and NC Contact Closing 40 … 50 ms
    Between Coil Energization and NC Contact Opening 45 … 85 ms
  • Connecting Capacity-Main Circuit:
    Rigid Al-Cable 120…240 mm²
    Bar 32 mm
    Rigid Cu-Cable 16…240 mm²
  • Connecting Capacity-Auxiliary Circuit:
    Solid 2x1…4 mm²
    Flexible with Insulated Ferrule 2x0.75…2.5 mm²
    Stranded 2x1…4 mm²
    Flexible 2x0.75…2.5 mm²
    Flexible with Ferrule 2x0.75…2.5 mm²
  • Degree of Protection:
    acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
    acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
  • Connecting terminals (delivered in open position) Main poles:
    Flat type c/w screws and bolts
  • Terminal Type:
    Main Circuit: Bars

Environmental

  • Ambient Air Temperature:
    Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25…+50 °C
    Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40…+70 °C
    Close to Contactor for Storage -40…+70 °C
  • Maximum Operating Altitude Permissible:
    3000 m
  • Resistance to Shock acc. to IEC 60068-2-27:
    Shock Direction: A 5 g
    Shock Direction: C2 5 g
    Shock Direction: C1 5 g
    Shock Direction: B2 5 g
    Shock Direction: B1 5 g
  • RoHS Status:
    Following EU Directive 2002/95/EC August 18, 2005 and amendment

Technical UL/CSA

  • Maximum Operating Voltage UL/CSA:
    Main Circuit 600 V
  • Horsepower Rating UL/CSA:
    (208 V AC) Three Phase 100 Hp
    (440 ... 480 V AC) Three Phase 250 Hp
    (550 ... 600 V AC) Three Phase 300 Hp
    (220 ... 240 V AC) Three Phase 100 Hp
    (200 V AC) Three Phase 100 Hp

Certificates and Declarations (Document Number)

Classifications

  • ETIM 5:
    EC000066 - Magnet contactor, AC-switching
  • UNSPSC:
    39121529

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.