AF1350-30-11 1SFL657001R7011 ABB AF1350-30-11 100-250V 50/60Hz / 100-250V DC Contactor View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

AF1350-30-11 1SFL657001R7011 ABB AF1350-30-11 100-250V 50/60Hz / 100-250V DC Contactor

1SFL657001R7011

ABB

AF1350-30-11 100-250V 50/60Hz / 100-250V DC Contactor

More details


Low-voltage industrial components > Power contactor, AC switching

Contactors and overload relays > Contactors "A" SECRLP

* Brand new product in its original packaging covered by the warranties and certifications provided by ABB

Total price: $5,805.85
Unit price: $5,805.85

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 1000 V. Operated with wide control voltage range 100-250 V, AC/DC

Ordering

  • EAN:
    7320500250143
  • Minimum Order Quantity:
    1 piece
  • Customs Tariff Number:
    85364900

Dimensions

  • Product Net Width:
    438.0mm
  • Product Net Depth:
    244.0mm
  • Product Net Height:
    392.0mm
  • Product Net Weight:
    33.000kg

Container Information

  • Package Level 1 Units:
    1 piece
  • Package Level 1 Width:
    250 mm
  • Package Level 1 Length:
    440 mm
  • Package Level 1 Height:
    430 mm
  • Package Level 1 Gross Weight:
    38 kg
  • Package Level 1 EAN:
    7320500250143
  • Package Level 2 Units:
    1

Technical

  • Number of Main Contacts NO:
    3
  • Number of Main Contacts NC:
    0
  • Number of Auxiliary Contacts NO:
    1
  • Number of Auxiliary Contacts NC:
    1
  • Rated Operational Voltage:
    Main Circuit 1000 V
  • Rated Frequency (f):
    Main Circuit 50/60 Hz
  • Conventional Free-air Thermal Current (Ith):
    acc. to IEC 60947-4-1, Open Contactors q = 40 °C 1350 A
  • Rated Operational Current AC-1 (Ie):
    (690 V) 55 °C 1150 A
    (690 V) 40 °C 1350 A
    (1000 V) 40 °C 1350 A
    (1000 V) 55 °C 1150 A
    (690 V) 70 °C 1000 A
    (1000 V) 70 °C 1000 A
  • Rated Operational Current AC-3 (Ie):
    (690 V) 55 °C 800 A
    (415 V) 55 °C 860 A
    (220 / 230 / 240 V) 55 °C 860 A
    (440 V) 55 °C 860 A
    (380 / 400 V) 55 °C 860 A
    (500 V) 55 °C 800 A
  • Rated Operational Power AC-3 (Pe):
    (500 V) 560 kW
    (690 V) 750 kW
    (220 / 230 / 240 V) 257 kW
    (380 / 400 V) 475 kW
    (440 V) 560 kW
    (415 V) 500 kW
  • Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
    10 x Ie AC-3
  • Rated Short-time Withstand Current (Icw):
    at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 6000 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 8000 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1600 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 10000 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 4500 A
  • Maximum Breaking Capacity:
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 10000 A
  • Maximum Electrical Switching Frequency:
    AC-3 60 cycles per hour
    AC-1 60 cycles per hour
    AC-2 / AC-4 60 cycles per hour
  • Rated Operational Current DC-1 (Ie):
    (850 V) 3 Poles in Series, 40 °C 1350 A
    (600 V) 3 Poles in Series, 40 °C 1350 A
    (220 V) 3 Poles in Series, 40 °C 1350 A
  • Rated Operational Current DC-3 (Ie):
    (850 V) 3 Poles in Series, 40 °C 1350 A
    (600 V) 3 Poles in Series, 40 °C 1350 A
    (220 V) 3 Poles in Series, 40 °C 1350 A
  • Rated Operational Current DC-5 (Ie):
    (850 V) 3 Poles in Series, 40 °C 1350 A
    (600 V) 3 Poles in Series, 40 °C 1350 A
    (220 V) 3 Poles in Series, 40 °C 1350 A
  • Rated Insulation Voltage (Ui):
    acc. to UL/CSA 600 V
    acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
  • Rated Impulse Withstand Voltage (Uimp):
    Main Circuit 8 kV
  • Mechanical Durability:
    0.5 million
  • Maximum Mechanical Switching Frequency:
    300 cycles per hour
  • Coil Operating Limits:
    (acc. to IEC 60947-4-1)0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) °C
  • Rated Control Circuit Voltage (Uc):
    60 Hz 100 … 250 V
    50 Hz 100 … 250 V
    DC Operation 100 … 250 V
  • Coil Consumption:
    Pull-in at Max. Rated Control Circuit Voltage 60 Hz 2450 V·A
    Holding at Max. Rated Control Circuit Voltage DC 20.5 V·A
    Holding at Max. Rated Control Circuit Voltage 50 Hz 48 V·A
    Pull-in at Max. Rated Control Circuit Voltage DC 2290 V·A
    Pull-in at Max. Rated Control Circuit Voltage 50 Hz 2450 V·A
    Holding at Max. Rated Control Circuit Voltage 60 Hz 48 V·A
  • Operate Time:
    Between Coil Energization and NO Contact Closing 50 ... 80 ms
    Between Coil De-energization and NO Contact Opening 35 ... 55 ms
    Between Coil De-energization and NC Contact Closing 35 ... 55 ms
    Between Coil Energization and NC Contact Opening 50 ... 80 ms
  • Connecting Capacity-Main Circuit:
    Bar 100 mm
  • Connecting Capacity-Auxiliary Circuit:
    Solid 2x1…4 mm²
    Flexible with Insulated Ferrule 1x0.75…2.5 mm²
    Stranded 1x1…4 mm²
    Flexible 2x0.75…2.5 mm²
    Flexible with Ferrule 1x0.75…2.5 mm²
  • Degree of Protection:
    acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
    acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
  • Terminal Type:
    Main Circuit: Bars

Environmental

  • Ambient Air Temperature:
    Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25…+50 °C
    Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40…+70 °C
    Close to Contactor for Storage -40…+70 °C
  • Maximum Operating Altitude Permissible:
    3000 m
  • RoHS Status:
    No declaration needed

Technical UL/CSA

  • Maximum Operating Voltage UL/CSA:
    Main Circuit 600 V
  • General Use Rating UL/CSA:
    (600 V AC) 1350 A
  • Horsepower Rating UL/CSA:
    (440 ... 480 V AC) Three Phase 800 Hp
    (550 ... 600 V AC) Three Phase 1000 Hp
    (220 ... 240 V AC) Three Phase 400 Hp

Certificates and Declarations (Document Number)

Classifications

  • ETIM 5:
    EC000066 - Magnet contactor, AC-switching
  • UNSPSC:
    39121529

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.