Transformador de corriente IZMX16
Interruptores Automáticos Bastidor Abierto
* Producto nuevo en su embalaje original con todas las garantías y certificaciones de EATON-MOELLER
Gracias por su interés en nuestros productos, esperamos que el plazo indicado sea conveniente para usted.
Durante la tramitación del pedido podrá seleccionar el tipo de envío que mejor se adapte a sus necesidades: Aéreo Express 24Hrs, Terrestre Standard 48/72Hrs, etc.
Product range | Accessories | ||
Accessories | Current sensor for neutral conductor | ||
The external transformer is required for the earth-fault protection and earth-fault alarm functions. a) For the neutral conductor in the case of 3-pole circuit-breakers b) For directly measuring the ground fault current at the grounded neutral point in the case of 3-pole and 4-pole circuit-breakers. Donotplace a jumper (in the wiring between the transformer and the circuit-breaker's terminals) between: a) 15, 16 and 19, 20; b) 17, 18 and 19, 20. | |||
For use with | IZMX-DTV-G +IZMX-DTV-G +IZMX-DTV-GZ +IZMX-DTU-A IZMX-DTU-A +IZMX-DTU-AZ +IZMX-DTU-G IZMX-DTU-G +IZMX-DTU-AM IZMX-DTU-AM +IZMX-DTU-AMZ IZMX-DTU-GMZ IZMX-DTU-GM +IZMX-DTU-GM +IZMX-DTU-GZ IZMX-DTP-G IZMX-DTP-G +IZMX-DTP-GZ +IZMX-DTP-GM +IZMX-DTP-GMZ IZMX-DTP-GM | ||
Notes An additional control circuit terminal block is required. For fixed mounting circuit-breakers→#156593 and withdrawable unit circuit-breakers →#156590 |
Technical data for design verification | |||
Operating ambient temperature min. | °C | -25 | |
Operating ambient temperature max. | °C | 70 |
Low-voltage industrial components (EG000017) / Current transformer (EC002048) | |||
Electric engineering, automation, process control engineering / Signal processing / Transformer / Current transformer ([email protected] [AAB626011]) | |||
Model | Wound primary current converter | ||
Primary rated current | A | 1600 | |
Secondary rated current | A | 0 | |
Secondary rated apparent power | VA | 0 | |
Accuracy class | 1 | ||
Over voltage limiting factor | - | ||
Calibrated | No | ||
With shock protection | No | ||
Opening height | mm | 0 | |
Opening width | mm | 0 | |
Opening diameter | mm | 0 | |
Snap mounting | No | ||
With copper rail | No | ||
Secondary connection | Screw connection | ||
Number of primary inputs | 1 |
Título: | Tamaño: | Tipo: |
---|---|---|
PDF CATÁLOGO EATON DISTRIBUCIÓN ENERGIA ES.pdf | 16 Mbytes | |
Transformador de curriente IZMX16 - EATON - IZMX-CT16-N - 124188 | 147 Kbytes |
Ningún comentario por el momento.
Valoración: | |
Nombre: | |
Email: | |
Título: | |
Opinión: | |
¿Recomienda la compra de este producto? | |
Añadir comentario |
Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.