MCR-SL-CUC-100-I 2308027 PHOENIX CONTACT Universal current transducer, for measuring AC, DC, and distorted c.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

MCR-SL-CUC-100-I 2308027 PHOENIX CONTACT Universal current transducer, for measuring AC, DC, and distorted c..

MCR-SL-CUC-100-I

2308027

PHOENIX_CONTACT

Available

Ship on today

Universal current transducer, for measuring AC, DC, and distorted currents, 0 ... 100 A input current, 4 ... 20 mA output

More details


Energy Meters Control Analizers

INTERFACE Signal converters, switching devices, and power supply units - PHOENIX CONTACT

Energy meters. Monitoring - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+$204.95
2+$199.89
3+$197.39
4+$195.82
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Width90 mm
Height33.8 mm
Depth85 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 65 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Degree of protectionIP20

Input data

Input current range0 A ... 100 A
Overload capacity6 x IIN
Frequency measuring range20 Hz ... 6000 Hz (0 Hz)
Connection methodCable design: 32 mm diameter

Output data

Output nameCurrent output
Current output signal4 mA ... 20 mA
Max. output current< 25 mA
Load/output load current output< 300 Ω

Switching output

Output nameNo switching output

Power supply

Nominal supply voltage24 V DC
Supply voltage range20 V DC ... 30 V DC
Max. current consumption(30 + IOUT) mA
Power consumption1.65 W

Connection data

Conductor cross section solid min.0.25 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Stripping length10 mm

General

Maximum transmission error<± 1 % (of final value)
Temperature coefficient, typical0.02 %/K (0 ... 60°C)
0.04 %/K (-40 ... 65°C)
Linearity error<± 1 % (From the range end value)
Step response (10-90%)150 ms
Overvoltage categoryIII
Pollution degree2
Rated insulation voltage300 V AC
Test voltage input/output3.5 kV (50 Hz, 1 min.)
Test voltage input/power supply3.5 kV (50 Hz, 1 min.)
Noise emissionEN 61000-6-4
Noise immunityEN 61000-6-2
Colorgreen
Housing materialFrianyl B63 V0 GV30
ConformanceCE-compliant
UL, USA / CanadaUL/C-UL listed UL 508

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2308027-MCR-SL-CUC-100-IEnglish153 KbytesPHOENIX CONTACT-2308027-MCR-SL-CUC-100-I

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or