FLT-CP-N/PE-350-ST 2859686 PHOENIX CONTACT Type 1 / Class I / B arrester (lightning arrester) replacement pl.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

FLT-CP-N/PE-350-ST 2859686 PHOENIX CONTACT Type 1 / Class I / B arrester (lightning arrester) replacement pl..

FLT-CP-N/PE-350-ST

2859686

PHOENIX_CONTACT

10

Available

Ship on today

Type 1 / Class I / B arrester (lightning arrester) replacement plug for path N-PE, can be combined with FLASHTRAB compact series of products.

More details


Overvoltage Protection Over Voltage

TRABTECH Power and Signal Quality - PHOENIX CONTACT

Surge protection - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Height46.6 mm
Width35.45 mm
Depth56.4 mm
Horizontal pitch2 Div.

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-40 °C ... 80 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m (amsl (above mean sea level))
Permissible humidity (operation)5 % ... 95 %
Shock (operation)25g (half sinus / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation)5g (5 - 500 Hz/2.5 h/X, Y, Z)

General

Standards/specificationsIEC 61643-11 2011
EN 61643-11 2012
IEC test classificationI / II
T1 / T2
EN typeT1 / T2
IEC power supply systemTT
Lightning protection classI
SPD designVoltage-switching type
Mode of protectionN-PE
Mounting typeOn base element
Colorgray/blue
Housing materialPBT
Pollution degree2
Flammability rating according to UL 94V-0
TypeMale
Number of positions1
Surge protection fault messageoptical

Protective circuit

Nominal voltage UN240 V AC (TN - only N-PE)
240 V AC (TT - only N-PE)
Nominal frequency fN50 Hz (60 Hz)
Maximum continuous voltage UC350 V AC
Residual current IPE≤ 0.01 mA
Nominal discharge current In (8/20) µs100 kA
Impulse discharge current (10/350)˽µs, charge50 As
Impulse discharge current (10/350)˽µs, specific energy2500 kJ/Ω
Impulse discharge current (10/350)˽µs, peak value limp100 kA
Follow current interrupt rating Ifi100 A (350 V AC)
Voltage protection level Up≤ 1.5 kV
Residual voltage Ures≤ 1.5 kV (at In)
≤ 1 kV (at 10 kA)
≤ 0.9 kV (at 5 kA)
≤ 0.8 kV (at 3 kA)
Front of wave sparkover voltage at 6 kV (1.2/50) µs≤ 1.5 kV
TOV behavior at UT1200 V AC (200 ms / withstand mode)
Response time tA≤ 100 ns

UL specifications

SPD Type4CA
Maximum continuous operating voltage MCOV (N-G)264 V AC
Mode of protectionN-G
Power distribution system1S
Nominal frequency50/60 Hz
Measured limiting voltage MLV (N-G)1080 V
Nominal discharge current In (N-G)20 kA
Follow current (N-G)200 A (264 V AC)

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2859686-FLT-CP-N/PE-350-STEnglish121 KbytesPHOENIX CONTACT-2859686-FLT-CP-N/PE-350-ST