Type 1 / Class I / B arrester (lightning current arrester) with arc chopping spark gap, 1-channel. Housing width: 35 mm (2 div.)

More details


Overvoltage Protection Over Voltage

TRABTECH Power and Signal Quality - PHOENIX CONTACT

Surge protection - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+$189.46
2+$184.68
3+$182.32
4+$180.80
5+$180.43
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Height90 mm
Width35.5 mm
Depth65.5 mm
Horizontal pitch2 Div.

Ambient conditions

Degree of protectionIP20 (only when all terminal points are used)
Ambient temperature (operation)-40 °C ... 85 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Altitude≤ 2000 m (amsl (above mean sea level))
Permissible humidity (operation)5 % ... 95 %

General

IEC power supply systemTN-S
TN-C
TT
Housing materialPA 6.6
Flammability rating according to UL 94V-0
Colorblack
Standards for cearances and creepage distancesEN 60664-1
EN 61643-11
Mounting typeDIN rail: 35 mm
TypeRail-mountable module, one-piece
Number of positions1
Surge protection fault messageNone
Direction of action1L-N/PE

Protective circuit

IEC test classificationI
T1
EN typeT1
Nominal voltage UN230/400 V AC (TN)
Maximum continuous operating voltage UC (L-PEN)400 V AC
UT (TOV-proof)400 V (5 sec.)
Nominal frequency fN50 Hz (60 Hz)
Rated load current IL80 A
Residual current IPE< 0.1 mA
Standby power consumption PC≤ 40 mVA
Nominal discharge current In (8/20) µs (L-PEN)60 kA
Front of wave sparkover voltage at 6 kV (1.2/50) µs≤ 5 kV
Voltage protection level Up (L-PEN)≤ 5 kV
Response time tA (L-PE)≤ 100 ns
Max. backup fuse with branch wiring500 A AC (gG)
Max. backup fuse with V-type through wiring80 A AC (gG)
Short-circuit resistance IP with max. backup fuse (effective)25 kA
Short-circuit current rating ISCCR2.5 kA
Follow current quenching capacity Ifi (L-PEN)2.5 kA

Connection, protective circuit

Connection methodScrew connection
Connection type INBiconnect screw terminal block
Connection type OUTBiconnect screw terminal block
Screw threadM6
Tightening torque8 Nm
Stripping length17 mm
Conductor cross section flexible min.16 mm²
Conductor cross section flexible max.35 mm²
Conductor cross section solid min.10 mm²
Conductor cross section solid max.50 mm²
Conductor cross section AWG6 ... 1

Standards and Regulations

Standards/regulationsIEC 61643-11 2011
EN 61643-11 2012

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2800107-FLT 60-400English107 KbytesPHOENIX CONTACT-2800107-FLT 60-400

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or