The configurable frequency transducer is suitable for the connection of NAMUR proximity sensors as well as for sensors with NPN and PNP outputs. Configurable via DIP switch and teach-in wheel. Spring-cage connection, standard configuration.

More details


* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+$179.39
2+$174.82
3+$172.55
4+$171.10
5+$170.51
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Product description

The configurable 3-way isolated frequency transducer is suitable for the connection of NAMUR proximity sensors (IEC 60947-5-6 and EN 50227) as well as for sensors with NPN and PNP outputs that generate a frequency signal.

The measured values are converted into a linear current or voltage signal.

The device is configured via DIP switches. Alternatively, the frequency range can be configured with extended options via the teach-in wheel. The measuring transducer supports fault monitoring.

Dimensions

Width6.2 mm
Height93.1 mm
Depth102.5 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 65 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Degree of protectionIP20

Input data

Frequency inputFrequency input
Configurable/programmableYes
Frequency measuring range0.002 Hz ... 20 kHz (DIP switch)
Available input sourcesNPN/PNP transistor outputs
NAMUR initiators
Floating relay contact (dry contact)
Max. input amplitude30 V (incl. DC voltage)

Output data

Output nameVoltage output
Number of outputs1
Configurable/programmableYes
Voltage output signal0 V ... 5 V
1 V ... 5 V
0 V ... 10 V
10 V ... 0 V
Current output signal0 mA ... 20 mA
4 mA ... 20 mA
20 mA ... 0 mA
20 mA ... 4 mA
Max. output voltageapprox. 12.3 V
Max. output current24.6 mA
Load/output load voltage output≥ 10 kΩ
Load/output load current output500 Ω (at 20 mA)

Output data

Step response (0–99%)< 35 ms (At f > 500 Hz)

Power supply

Supply voltage range9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
Typical current consumption< 28 mA (at IOUT = 20 mA, 24 V DC, load 500 Ω)
Power consumption< 800 mW (at IOUT = 20 mA, 9.6 V DC, load 500 Ω)

Connection data

Connection methodSpring-cage connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Stripping length8 mm

General

No. of channels1
Maximum temperature coefficient0.01 %/K
Status displayLED red
Operating elementsPress/slide button
Protective circuitTransient protection
Electrical isolationBasic insulation according to EN 61010
Overvoltage categoryII
Pollution degree2
Rated insulation voltage50 V AC/DC
Test voltage, input/output/supply1.5 kV (50 Hz, 1 min.)
Electromagnetic compatibilityConformance with EMC Directive 2004/108/EC
Noise emissionEN 61000-6-4
Noise immunityEN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Colorgreen
Housing materialPBT
Mounting positionany
Assembly instructionsThe T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.
ConformanceCE-compliant
ATEXEx II 3 G Ex nA IIC T4 Gc X
UL, USA / CanadaUL 508 Listed
Class I, Div. 2, Groups A, B, C, D T4
Class I, Zone 2, Group IIC
Certificate of classificationDNV GL 14085-15HH

EMC data

DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
Typical deviation from the measuring range final value0.1 %
DesignationFast transients (burst)
Standards/regulationsEN 61000-4-4
Typical deviation from the measuring range final value2 %
DesignationConducted interferences
Standards/regulationsEN 61000-4-6
Typical deviation from the measuring range final value0.3 %

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2902833-MINI MCR-SL-F-UI-SP-NCEnglish115 KbytesPHOENIX CONTACT-2902833-MINI MCR-SL-F-UI-SP-NC

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or