IB IL 400 MLR 1-8A 2727365 PHOENIX CONTACT Inline power-level terminal blocks, electronic direct starter, up.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

IB IL 400 MLR 1-8A 2727365 PHOENIX CONTACT Inline power-level terminal blocks, electronic direct starter, up..

IB IL 400 MLR 1-8A

2727365

PHOENIX_CONTACT

Available

Ship on today

Inline power-level terminal blocks, electronic direct starter, up to 3.7 kW / 400 V AC

More details


AUTOMATION Industrial Automation - PHOENIX CONTACT

Control technology - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Product description

INTERBUS Inline power-level terminals enable standard three-phase motors to be switched, protected, and monitored via INTERBUS.

The terminals in the product range are available as direct and reversing starters in electronic and electromechanical versions.

Each power-level terminal is equipped with electronic motor protection and provides the same advantages as the INTERBUS motor starter, such as motor current monitoring, overcurrent protection, and quick shutdown according to IEC. The integrated controller supports motor current parameterization via INTERBUS in the performance ranges from 15 W to 1.5 kW and 0.1 kW to 3.7 kW.

As with all Inline automation terminals, the power-level terminals can be snapped on and mounted on a DIN rail without tools.

Labeling is carried out directly on the module using the familiar zack marker strip and a snap-on label with large-surface labeling option.

Additional features include:

- Mains voltage up to 400 V AC 3~

- Mains output power: electronic: 15 W to 1.5 kW, electromechanical version: 0.1 kW to 3.7 kW

- Manual local operation without bus supported

- Can be extended with brake function as an option

- Thermal motor monitoring using Inline thermistor terminal

Dimensions

Width63 mm
Height224 mm
Depth109 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 55 °C
Ambient temperature (storage/transport)-25 °C ... 85 °C
Permissible humidity (operation)75 % ... 85 % (75% average, 85% seldom)
Permissible humidity (storage/transport)75 % ... 85 % (75% average, 85% seldom)
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above mean sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above mean sea level)
Degree of protectionIP20

Interfaces

Fieldbus systemLokalbus
DesignationInline local bus
Connection methodInline data jumper
Transmission speed500 kBit/s
Transmission physicsCopper

Power supply for module electronics

Connection methodThrough the potential jumper
DesignationTerminal strips X11 and X12

Mains connection

DesignationMains connection
Connection methodPower connector or power bridge
Designation connection pointTerminal strip; X11 and X12
Number of positions5
Permissible conductor cross sectionmax. 2.5 mm² (L1+L2+L3+N-PE)
Operating voltage187 V AC ... 500 V AC +0 % (conductor voltage)
Max. current carrying capacity20 A

Motor starter, output

Connection method(3-phase), via COMBICON
Number1
Output nameMotor outputs (three phases), short-circuit-proof with external line protection fuse 20 A
Designation connection pointTerminal strip; X10
Number of positions4
Permissible conductor cross section1 mm² ... 2.5 mm²
Operating voltage200 V AC ... 600 V AC +0 %
Frequency range50 Hz ... 60 Hz
Nominal current range0.2 A ... 8 A
Switching rateMax. 5 cycles per minute

Motor monitoring

Parameterization range0.2 A ... 8 A (steps of 50/100/200 mA, via fieldbus)
Overspeed tripping≥ 40 A (after 0.3 seconds)

Thermistor input

Number of inputs2

Inline potentials

Communications power UL7.5 V
Current consumption from ULmax. 45 mA
Segment supply voltage US24 V DC (nominal value)
Current consumption from USmax. 160 mA

General

Net weight550 g
Note on weight specificationsWithout plug
Mounting typeDIN rail
NoteNotes on operation Line protection for the network supply line, max. 20 A. Observe derating of the POWER-COMBICON connector
Diagnostics messagesOvercurrent Error message in the diagnostic code (bus) and display via the LED ERR on the module
Output stage cannot be controlled Error message in the diagnostic code (bus) and display via the LED ERR on the module
Module error during self test Message to the master

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2727365-IB IL 400 MLR 1-8AEnglish154 KbytesPHOENIX CONTACT-2727365-IB IL 400 MLR 1-8A

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or