PT 2-TELE 2882828 PHOENIX CONTACT Surge protective device, consisting of plug and base element, for protecti.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PT 2-TELE 2882828 PHOENIX CONTACT Surge protective device, consisting of plug and base element, for protecti..

PT 2-TELE

2882828

PHOENIX_CONTACT

10

Available

Ship on today

Surge protective device, consisting of plug and base element, for protecting a double wire from analog and digital telecommunications interfaces (VDSL up to 50 Mbps).

More details


Overvoltage Protection Over Voltage

TRABTECH Power and Signal Quality - PHOENIX CONTACT

Surge protection for information technology - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Product description

Surge protection plug for DIN rail mounting, 2-section pluggable, normal mode voltage coarse and fine protection for 2-conductor analog telecommunication interface as well as common mode voltage coarse protection to ground.

Dimensions

Height90 mm
Width17.7 mm
Depth65.5 mm
Horizontal pitch1 Div.
Complete module height90 mm
Complete module width17.7 mm
Complete module depth65.5 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 85 °C
Degree of protectionIP20

General

Housing materialPA
Flammability rating according to UL 94V0
Colorblack
Standards for cearances and creepage distancesVDE 0110-1
IEC 60644-1
Mounting typeDIN rail: 35 mm
TypeDIN rail module, two-section, divisible
Number of positions2
Direction of actionLine-Line & Line-Earth Ground
Transmission speed16 Mbit/s

Protective circuit

IEC test classificationC1
C2
C3
D1
B2
VDE requirement classC1
C2
C3
D1
B2
Maximum continuous voltage UC185 V DC
130 V AC
Maximum continuous voltage UC (wire-wire)185 V DC
130 V AC
Maximum continuous voltage UC (wire-ground)185 V DC
130 V AC
Nominal current IN450 mA (45°C)
Operating effective current IC at UC≤ 10 µA
Standby power consumption PC≤ 980 mVA
Residual current IPE≤ 10 µA
Nominal discharge current In (8/20) µs (Core-Core)10 kA
Nominal discharge current In (8/20) µs (Core-Earth)10 kA
Total surge current (8/20) µs20 kA
Max. discharge current Imax (8/20) µs maximum (Core-Earth)18 kA
Nominal pulse current Ian (10/700) µs (Core-Core)100 A
Nominal pulse current Ian (10/700) µs (Core-Earth)100 A
Impulse discharge current (10/350)˽µs, peak value limp1 kA
Output voltage limitation at 1 kV/µs (Core-Core) static≤ 300 V
Output voltage limitation at 1 kV/µs (Core-Earth) static≤ 300 V
Residual voltage at In (conductor-conductor)≤ 160 V (C2 - 10 kV / 5 kA)
Residual voltage at In (conductor-ground)≤ 200 V (C2 - 10 kV / 5 kA)
Voltage protection level Up (core-core)≤ 330 V (C2 - 10 kV / 5 kA)
≤ 300 V (C2 - 2 kV/1 kA)
≤ 270 V (C1 - 1 kV/500 A)
≤ 300 V (B2 - 4 kV/100 A)
Voltage protection level Up (core-ground)≤ 300 V (C2 - 2 kV/1 kA)
Response time tA (Core-Core)≤ 500 ns
Response time tA (Core-Earth)≤ 500 ns
Input attenuation aE, sym.typ. 0.4 dB (≤ 5 MHz)
Cut-off frequency fg (3 dB), sym. in 100 Ohm systemtyp. 20 MHz
Capacity (Core-Core)typ. 30 pF
Capacity (Core-Earth)typ. 30 pF
Resistance in series2.2 Ω ±10 %
Impulse durability (conductor-conductor)B2 - 4 kV/100 A
C1 - 1 kV/500 A
C2 - 10 kV/5 kA
C3 - 2 kV/25 A
D1 - 1 kA
Impulse durability (conductor-ground)B2 - 4 kV/100 A
C1 - 1 kV/500 A
C2 - 10 kV/5 kA
C3 - 2 kV/25 A
D1 - 1 kA

Connection data

Connection methodScrew connection
Connection type INScrew terminal blocks
Connection type OUTScrew terminal blocks
Screw threadM3
Tightening torque0.8 Nm
Stripping length8 mm
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.4 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12

Standards and Regulations

Standards/regulationsIEC 61643-21

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2882828-PT 2-TELEEnglish299 KbytesPHOENIX CONTACT-2882828-PT 2-TELE

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or