CT 10-9VA-230AC 2830498 PHOENIX CONTACT LSA-PLUS plug (COMTRAB CT 10) with surge protection incl. visual fau.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

CT 10-9VA-230AC 2830498 PHOENIX CONTACT LSA-PLUS plug (COMTRAB CT 10) with surge protection incl. visual fau..

CT 10-9VA-230AC

2830498

PHOENIX_CONTACT

Available

Ship on today

LSA-PLUS plug (COMTRAB CT 10) with surge protection incl. visual fault warning for nine 2-core signal circuits. Nominal voltage: 230 V AC. Design: 10 double wires

More details


Overvoltage Protection Over Voltage

TRABTECH Power and Signal Quality - PHOENIX CONTACT

Surge protection for measurement and control technology - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+$354.47
2+$346.92
3+$345.67
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Height22 mm
Width111 mm
Depth68.5 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 85 °C
Degree of protectionIP20

General

Housing materialPBT
Flammability rating according to UL 94V2
Colorblack
Standards for cearances and creepage distancesVDE 0110-1
IEC 60664
Mounting typeOn CT-TERMIBLOCK and LSA-PLUS disconnect strip
TypeLSA-PLUS module
Direction of actionLine-Line & Line-Earth Ground
Arrester can be tested with CHECKMASTER from software version:From SW rev. 1.00

Protective circuit

IEC test classificationC1
C3
Nominal voltage UN230 V AC
Maximum continuous voltage UC275 V DC
275 V AC
Maximum continuous voltage UC (wire-ground)275 V DC
275 V AC
Maximum continuous voltage UC (wire-GND)275 V DC
275 V AC
Nominal current IN1.5 A
Operating effective current IC at UC≤ 1.5 mA
≤ 2 mA
Residual current IPE≤ 1 µA
Nominal discharge current In (8/20) µs (Core-Earth)1.5 kA
Nominal discharge current In (8/20) µs (Core-GND)1.5 kA
Nominal discharge current In (8/20) µs (GND-Ground)5 kA
Total surge current (8/20) µs5 kA
Max. discharge current Imax (8/20) µs maximum (Core-Earth)5 kA (10-PE)
Max. discharge current Imax (8/20) µs maximum (Core-GND)4.5 kA (10)
Residual voltage at In (conductor-ground)≤ 1.4 kV
Residual voltage at In (conductor-GND)≤ 1.1 kV
Fixed cable length10 m
Enery absorption, asymmetrical71 J
Voltage protection level Up (core-ground)≤ 1.4 kV (10-PE)
Voltage protection level Up (core-GND)≤ 1.1 kV (10)
Response time tA (Core-Core)≤ 25 ns
Response time tA (Core-Earth)≤ 25 ns
≤ 100 ns
Frequency range50 Hz ... 60 Hz
Capacity (Core-GND)320 pF (10)
Capacity (Core-Earth)2 pF (10-PE)
Surge protection fault messageoptical
Max. required back-up fuse1.5 A (gL)

Connection data

Connection methodcan be plugged into COMTRAB-TERMIBLOCK and LSA-PLUS disconnect and switching strips
Connection type INCOMTRAB plug-in system
Connection type OUTCOMTRAB plug-in system

Standards and Regulations

Standards/regulationsIEC 61643-21

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2830498-CT 10-9VA-230ACEnglish151 KbytesPHOENIX CONTACT-2830498-CT 10-9VA-230AC