PT-IQ-1X2-24DC-PT 2801255 PHOENIX CONTACT Surge protection, consisting of protective plug and base element, .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PT-IQ-1X2-24DC-PT 2801255 PHOENIX CONTACT Surge protection, consisting of protective plug and base element, ..

PT-IQ-1X2-24DC-PT

2801255

PHOENIX_CONTACT

Available

Ship on today

Surge protection, consisting of protective plug and base element, with integrated multi-stage status indicator on the module for one 2-wire floating signal circuit.

More details


* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+$171.78
2+$167.34
3+$165.15
4+$163.74
5+$162.97
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Height109.3 mm
Width17.7 mm
Depth77.5 mm
Horizontal pitch1 Div.

Ambient conditions

Ambient temperature (operation)-40 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Degree of protectionIP20

General

Housing materialPA 6.6
Flammability rating according to UL 94V-0
Colorjet black RAL 9005
Mounting typeDIN rail: 35 mm
TypeDIN rail module, two-section, divisible
Direction of actionLine-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground

Protective circuit

IEC test classificationC1
C2
C3
D1
Nominal voltage UN24 V DC
Maximum continuous voltage UC30 V DC
21 V AC
Nominal current IN1000 mA (40°C)
Operating effective current IC at UC≤ 1 mA (in the signal circuit)
Residual current IPE≤ 2 µA (per signal circuit)
Nominal discharge current In (8/20) µs (Core-Core)10 kA
Nominal discharge current In (8/20) µs (Core-Earth)10 kA
Pulse discharge current Iimp (10/350) µs (core-ground)2.5 kA
Impulse discharge current (10/350)˽µs, peak value limp2.5 kA
Voltage protection level Up (core-core)≤ 80 V (C1 - 1 kV/500 A)
≤ 130 V (C2 - 10 kV / 5 kA)
≤ 55 V (C3 - 25 A)
≤ 60 V (C3 - 100 A)
Voltage protection level Up (core-ground)≤ 600 V (C1 - 1 kV/500 A)
≤ 750 V (C2 - 10 kV / 5 kA)
≤ 700 V (C3 - 25 A)
≤ 800 V (C3 - 100 A)
Voltage protection level Up static (core-core)≤ 65 V (C1 - 1 kV/500 A)
Voltage protection level Up static (core-ground)≤ 60 V (C2 - 10 kV / 5 kA)
≤ 40 V (C3 - 25 A)
≤ 100 V (C3 - 100 A)
Response time tA (Core-Core)≤ 1 ns
Response time tA (Core-Earth)≤ 100 ns
Input attenuation aE, sym.typ. 0.3 dB (≤ 270 kHz/150 Ω)
Cut-off frequency fg (3 dB), sym. in 150 Ohm systemtyp. 1.1 MHz
Capacity (Core-Core)typ. 2 nF
Resistance in series1.2 Ω ±5 %
Surge protection fault messageOptical, multi-stage
Max. required back-up fuse1 A (FF)
Impulse durability (conductor-conductor)C1 - 1 kV/500 A
C2 - 10 kV/5 kA
C2 - 10 kA
C3 - 100 A
Impulse durability (conductor-ground)C1 - 1 kV/500 A
C2 - 10 kV/5 kA
C2 - 10 kA
C3 - 100 A
D1 - 2,5 kA
Pulse reset time (conductor-conductor)≤ 4000 ms
Pulse reset time (conductor-ground)≤ 2600 ms

Connection data

Connection methodPush-in connection
Connection type INPush-in connection
Connection type OUTPush-in connection
Stripping length10 mm
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.4 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12

Connection, equipotential bonding

Connection methodNS 35 DIN rail or connection terminal block

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2801255-PT-IQ-1X2-24DC-PTEnglish277 KbytesPHOENIX CONTACT-2801255-PT-IQ-1X2-24DC-PT

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or