VAL-MS-T1/T2 175/12.5/1+1 2800675 PHOENIX CONTACT Universal varistor-based plug-in lightning/surge arrester .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

VAL-MS-T1/T2 175/12.5/1+1 2800675 PHOENIX CONTACT Universal varistor-based plug-in lightning/surge arrester ..

VAL-MS-T1/T2 175/12.5/1+1

2800675

PHOENIX_CONTACT

Available

Ship on today

Universal varistor-based plug-in lightning/surge arrester for 1-phase power supply networks with separate N and PE (3-conductor system: L1, N, PE).

More details


Overvoltage Protection Over Voltage

TRABTECH Power and Signal Quality - PHOENIX CONTACT

Surge protection - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+$180.63
2+$176.02
3+$173.73
4+$172.27
5+$171.67
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Height90 mm
Width35.6 mm
Depth77.5 mm
Horizontal pitch2 Div.

Ambient conditions

Degree of protectionIP20 (only when all terminal points are used)
Ambient temperature (operation)-40 °C ... 80 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m (amsl (above mean sea level))
Permissible humidity (operation)5 % ... 95 %
Shock (operation)30g
Vibration (operation)7.5g

General

IEC power supply systemTT
TN-C
TN-S
Housing materialPA 6.6
PBT
Flammability rating according to UL 94V-0
Colorblack
Standards for cearances and creepage distancesDIN EN 60664-1
EN 61643-11
Mounting typeDIN rail: 35 mm
TypeDIN rail module, two-section, divisible
Surge protection fault messageoptical
Direction of action1L-N & N-PE

Protective circuit

IEC test classificationI / II
T1 / T2
T1
I
EN typeT1 / T2
T1
Nominal voltage UN120 V AC (TN-S)
Maximum continuous operating voltage UC (L-N)175 V AC
Maximum continuous operating voltage UC (N-PE)264 V AC
UT (TOV-proof)208 V AC (5 s / L-N)
1200 V AC (200 ms / N-PE)
Nominal frequency fN50 Hz (60 Hz)
Rated load current IL80 A
Residual current IPE≤ 5 µA
Standby power consumption PC≤ 140 mVA
Max. discharge current Imax (8/20) µs maximum (L-N)50 kA
Max. discharge current Imax (8/20) µs maximum (N-PE)50 kA
Nominal discharge current In (8/20) µs (L-N)12.5 kA
Nominal discharge current In (8/20) µs (N-PE)50 kA
Impulse discharge current (10/350) µs (L-N), charge6.25 As
Impulse discharge current (10/350)˽µs, specific energy39 kJ/Ω
Impulse discharge current (10/350) µs (L-N), peak current value Iimp12.5 kA
Impulse discharge current (10/350) µs (N-PE), charge25 As
Impulse discharge current (10/350) µs (N-PE), specific energy625 kJ/Ω
Impulse discharge current (10/350) µs (N-PE), peak current value Iimp50 kA
Front of wave sparkover voltage at 6 kV (1.2/50) µs (N-PE)≤ 1.7 kV
Voltage protection level Up (L-N)≤ 0.8 kV
Voltage protection level Up (L-PE)≤ 2 kV
Voltage protection level Up (N-PE)≤ 1.7 kV
Residual voltage (L-N)≤ 0.65 kV (at 10 kA)
≤ 0.6 kV (at 5 kA)
≤ 0.5 kV (at 3 kA)
≤ 0.8 kV
Residual voltage (L-PE)≤ 1.5 kV (at 10 kA)
≤ 1.4 kV (at 5 kA)
≤ 1.3 kV (at 3 kA)
≤ 2 kV
Residual voltage (N-PE)≤ 0.5 kV (at 10 kA)
≤ 0.5 kV (at 5 kA)
≤ 0.4 kV (at 3 kA)
≤ 0.6 kV
Response time tA (L-N)≤ 25 ns
Response time (L-PE)≤ 100 ns
Response time tA (N-PE)≤ 100 ns
Max. backup fuse with branch wiring160 A AC (gG)
Max. backup fuse with V-type through wiring80 A AC (gG - 16 mm²)
Short-circuit resistance IP with max. backup fuse (effective)25 kA
Short-circuit current rating ISCCR25 kA
Follow current quenching capacity Ifi (N-PE)100 A (264 V AC)

Connection, protective circuit

Connection methodScrew connection
Connection type INBiconnect screw terminal block
Connection type OUTBiconnect screw terminal block
Connection methodBiconnect terminal block
Screw threadM5
Tightening torque4.5 Nm
30 lbf-in. (UL)
Stripping length16 mm
Conductor cross section flexible min.1.5 mm²
Conductor cross section flexible max.25 mm²
Conductor cross section solid min.1.5 mm²
Conductor cross section solid max.35 mm²
Conductor cross section AWG15 ... 2
10 ... 2 (UL)

Standards and Regulations

Standards/regulationsIEC 61643-11 2011
EN 61643-11 2012

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2800675-VAL-MS-T1/T2 175/12.5/1+1English132 KbytesPHOENIX CONTACT-2800675-VAL-MS-T1/T2 175/12.5/1+1

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or