Type 2 surge arrester for 5-wire power supply systems (L1, L2, L3, N, PE), with connector latching.
Trabtech (TT)
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Height | 90 mm |
---|---|
Width | 71.2 mm |
Depth | 77.5 mm |
Horizontal pitch | 4 Div. |
Degree of protection | IP20 |
---|---|
IP20 (only when all terminal points are used) | |
Ambient temperature (operation) | -40 °C ... 80 °C |
Ambient temperature (storage/transport) | -40 °C ... 80 °C |
Altitude | ≤ 2000 m (amsl (above mean sea level)) |
Permissible humidity (operation) | 5 % ... 95 % |
Shock (operation) | 30g |
Vibration (operation) | 7.5g |
Standards/specifications | IEC 61643-11 2011 |
---|---|
EN 61643-11 2012 | |
IEC test classification | II |
T2 | |
EN type | T2 |
IEC power supply system | TT |
TN-C | |
TN-S | |
Number of ports | One |
SPD design | Combination type |
Mode of protection | L-N |
N-PE | |
Mounting type | DIN rail: 35 mm |
Color | black |
Housing material | PA 6.6 |
PBT | |
Degree of pollution | 2 |
Flammability rating according to UL 94 | V-0 |
Type | DIN rail module, two-section, divisible |
Surge protection fault message | optical |
Nominal voltage UN | 240/415 V AC (TN-S) |
---|---|
240/415 V AC (TT) | |
Nominal frequency fN | 50 Hz (60 Hz) |
Maximum continuous operating voltage UC (L-N) | 385 V AC |
Maximum continuous voltage UC (N-PE) | 264 V AC |
Rated load current IL | 80 A |
Residual current IPE | ≤ 5 µA |
Standby power consumption PC | ≤ 690 mVA |
Nominal discharge current In (8/20) µs (L-N) | 30 kA |
Nominal discharge current In (8/20) µs (N-PE) | 40 kA |
Maximum discharge current Imax (8/20) µs (L-N) | 65 kA |
Maximum discharge current Imax (8/20) µs (N-PE) | 80 kA |
Impulse discharge current (10/350) µs (L-N), charge | 1.25 As |
Impulse discharge current (10/350) µs (L-N), specific energy | 1.56 kJ/Ω |
Impulse discharge current (10/350) µs (L-N), peak current value Iimp | 2.5 kA |
Impulse discharge current (10/350) µs (N-PE), charge | 5 As |
Impulse discharge current (10/350) µs (N-PE), specific energy | 25 kJ/Ω |
Impulse discharge current (10/350) µs (N-PE), peak current value Iimp | 10 kA |
Total discharge current ITotal (8/20) µs | 80 kA |
Total discharge current ITotal (10/350) µs | 10 kA |
Follow current interrupt rating Ifi (N-PE) | 100 A (264 V AC) |
Short-circuit current rating ISCCR | 25 kA |
Voltage protection level Up (L-N) | ≤ 1.8 kV |
Voltage protection level Up (L-PE) | ≤ 2 kV |
Voltage protection level Up (N-PE) | ≤ 1.7 kV |
Residual voltage Ures (L-N) | ≤ 1.8 kV (at In) |
≤ 1.4 kV (at 10 kA) | |
≤ 1.25 kV (at 5 kA) | |
≤ 1.2 kV (at 3 kA) | |
Residual voltage Ures (L-PE) | ≤ 2 kV (at In) |
≤ 1.5 kV (at 10 kA) | |
≤ 1.4 kV (at 5 kA) | |
≤ 1.3 kV (at 3 kA) | |
Residual voltage Ures (N-PE) | ≤ 0.6 kV (at In) |
≤ 0.5 kV (at 10 kA) | |
≤ 0.5 kV (at 5 kA) | |
≤ 0.4 kV (at 3 kA) | |
Front of wave sparkover voltage at 6 kV (1.2/50) µs (N-PE) | ≤ 1.7 kV |
TOV behavior at UT (L-N) | 480 V AC (5 s / withstand mode) |
TOV behavior at UT (N-PE) | 1200 V AC (200 ms / withstand mode) |
Response time tA (L-N) | ≤ 25 ns |
Response time tA (L-PE) | ≤ 100 ns |
Response time tA (N-PE) | ≤ 100 ns |
Max. backup fuse with branch wiring | 250 A (gG) |
Max. backup fuse with V-type through wiring | 80 A AC (gG - 16 mm²) |
Connection method | Screw connection |
---|---|
Conductor cross section flexible | 1.5 mm² ... 25 mm² |
Conductor cross section solid | 1.5 mm² ... 35 mm² |
Conductor cross section AWG | 15 ... 2 |
Screw thread | M5 |
Tightening torque | 4.5 Nm |
Stripping length | 16 mm |
eCl@ss 4.0 | 27140201 |
---|---|
eCl@ss 4.1 | 27130801 |
eCl@ss 5.0 | 27130801 |
eCl@ss 5.1 | 27130801 |
eCl@ss 6.0 | 27130805 |
eCl@ss 7.0 | 27130805 |
eCl@ss 8.0 | 27130806 |
eCl@ss 9.0 | 27130806 |
ETIM 2.0 | EC000941 |
---|---|
ETIM 3.0 | EC000941 |
ETIM 4.0 | EC000941 |
ETIM 5.0 | EC000941 |
UNSPSC 6.01 | 30212010 |
---|---|
UNSPSC 7.0901 | 39121610 |
UNSPSC 11 | 39121610 |
UNSPSC 12.01 | 39121610 |
UNSPSC 13.2 | 39121620 |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX PROTECTION EN.pdf | 27 Mbytes | |
PHOENIX CONTACT-2920890-VAL-MS 385/65/3+1 | 120 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.